ChronTrol
XT Series Timers
User's Guide
39
Set Program #2
1.
Press
ENTER
, then
2
.
E–02
displays.
2.
Press
CIRCUIT
, then
2
.
C–02
displays.
3.
Press
ON
, then
6 0 0
.
600
displays.
4.
Press
OFF
, then
4 0 0 AM/PM
.
400.
displays.
5.
Press
DAY/OMIT
, then
1 2 3 4 5
. Strokes for Monday through Friday
display.
6.
Press
ENTER
to store the last entry followed by
TIME
to return to the
Time of Day display.
Sample Program 4: Interval Program with Cycle
Desired effect:
To turn Circuit #3 ON for one second, then OFF for four
seconds, over and over again.
Plan:
Make the next available program a 1-second On-Off Interval with a 5-
second Cycle Length. Start and stop the program through the keyboard.
Set Program #1.
1.
Press
ENTER ENTER
.
P–
n
.
displays, where
n
is the number of the next
available program.
2.
Press
CIRCUIT
, then
3
.
C–03
displays.
3.
Press
INTERVAL
, then
0
.
0000
displays.
4.
Press
SECOND
, then
1
.
000001
displays.
5.
Press
CYCLE 0 SECOND 5
.
000005
displays.
6.
Press
ENTER
to store the last entry, then press
TIME
to return to the
Time of Day display.
Start the Program.
1.
Press
PROGRAM
n
ON
, where
n
is the same program number given
above. Time of Day displays and Circuit #3 starts clicking ON and OFF.
Stop the Program.
1.
Press
PROGRAM
n
OFF
. Time of Day displays and Circuit #3 stops
clicking.
NOTE
: Circuit #3 will remain ON if you turned the program
OFF before it turned the circuit OFF.