Thermal Performance
The internal cooling system of the Inspire Mini is by convection. When the internal temperature exceeds 75
º
C, the output of
the fixture is reduced for automatic protection. This happens on rare and extreme conditions when ambient temperature is
over 35
º
C.
3.
Troubleshooting
Troubleshooting is a process of elimination. First, rule out the other field factors (i.e. bad connections, faulty cables and
power supplies). For technical support and/or parts, please contact your selling dealer or the offices listed in this manual.
Symptom
Possible Cause
Solution
Fixture does not respond to DMX control.
•
Set to wrong or different DMX
address.
•
Bad cable connecting DMX control
and fixture.
•
Bad in/through connection between
adjacent fixtures.
•
Check DMX address and Mode
settings.
•
Check/replace DMX run from the
console.
Low LED output.
•
Internal temperature is over the
limit.
•
Check area ventilation.