Figure 8. Install cooling duct 

 

Figure 9. 

13.  Cover the two open slots in the PHM (where the lens-horizontal mounting 

brackets fit into the module) with the two all-black labels. Covering these slots 
will prevent any excess light from passing through and reflecting onto the optical 
mirror and screen used in typical lens-vertical rear projection applications. If not 
covered, the brightness and clarity of a displayed image may be affected. See 
Figure 10. 

Содержание RPMSP-500Xe 38-GFX208 Series

Страница 1: ...s In general the following steps must be completed to successfully setup your projector 1 Unpack the projector 2 Choose the projector s configuration lens vertical or lens horizontal 3 Calculate throw distance position and mount projector 4 Connect sources 5 Power projector on 6 Adjust projection lens for focus and lateral image color 7 Adjust software to optimize image on one or multiple screens ...

Страница 2: ...e models Electronics Module Projection Head Module Ballast Module J91 J90 J94 J89 J88 J102 to P103 The projector can be configured in two ways with the lens at 0 lens horizontal or 90 lens vertical The latter is typically used in installations where a first surface optical mirror is used Refer to the instructions for your specific model to change the configuration if necessary WARNING Projector mu...

Страница 3: ...ws from the front mounting bracket with tabs 6 Tilt the PHM up slightly and pull it back just enough to unhook it from the two tabs on the front mounting bracket Remove the PHM Figure 3 7 Remove the rear mounting bracket 3 screws and the front mounting bracket 2 screws from the adjuster top plate 8 Replace the brackets removed in the step above with the new front and rear mounting brackets shipped...

Страница 4: ...n the flange 90 degrees so the mounting holes used to secure the cooling duct assembly align with the mounting holes in the side of the lamp housing Re assemble the cooling duct assembly and slide it back into position When the cooling duct assembly is inserted the wire mesh side of the cooling duct should be facing out the rear of the projector away from the screen b Install the lamp housing top ...

Страница 5: ...ounting brackets fit into the module with the two all black labels Covering these slots will prevent any excess light from passing through and reflecting onto the optical mirror and screen used in typical lens vertical rear projection applications If not covered the brightness and clarity of a displayed image may be affected See Figure 10 ...

Страница 6: ...projector is off and unplugged disconnect all cable connections made to the PHM and DLM 2 Loosen the captive screws securing the PHM and DLM assembly to the adjuster mounting brackets Figure 11 Figure 11 3 Lift the PHM DLM assembly off the adjuster and set aside 4 Tilt the mounting rails to access the 4 screws securing the adjuster to the bottom mounting plate Remove adjuster 5 Align the adjuster ...

Страница 7: ...nnector Tighten the hex screw on the connector to secure both modules together Figure 15 Figure 15 10 Replace the louvered side panels removed in Step 6 11 Remove the PHM mounting bracket from the adjuster 2 screws The DLM mounting bracket remains the same Figure 16 12 Place the mounting bracket shipped with the projector for 90 degree configuration over the mounting holes on the adjuster Figure 1...

Страница 8: ...RPMSP Series Installation Guide 8 Figure 16 16 Lower the PHM DLM assembly onto the adjuster and secure to the mounting brackets 2 screws each Figure 17 Figure 17 ...

Страница 9: ...tween the projector and screen by folding the optical path throw distance is a little more difficult to calculate as there are many variables to consider Refer to the drawings provided for your specific projector model at the end of this guide for projector dimensions and other technical information There are four mounting points to each projector Using the appropriate hardware mount the projector...

Страница 10: ...e next one until all units are adjusted When all units on the bottom row are adjusted move on to the next row Continue until all projectors in the display are adjusted Tools required 3 16 ball driver 3 32 allen key TIP Refer to Figure 19 when adjusting the 6 axis adjuster 1 Display a test pattern with bold geometric shapes like circles squares and a solid outer border when setting up a projector f...

Страница 11: ...on menu and to change the orientation of the displayed image to suit the installation For example in rear screen installations select rear from the pull down list for the image to display correctly from the audiences perspective 5 Modify Language and any settings in Menu Preferences to suit your needs 6 Enable Broadcast Key in the Communications menu this enables you to switch between communicatin...

Страница 12: ... necessary 13 If required readjust H Position and V Position to center the image 14 Perform Color Temperature Setup 15 Adjust black levels and input levels for quick setup of these enable Peak Detector in the Input Levels menu 16 Select a Lamp Mode setting from the Lamp menu Adjust Intensity to match lamp brightness of adjacent projectors 100W recommended 17 Adjust color primaries brightness unifo...

Страница 13: ...Appendix A Projector Dimensions Throw Distance 13 Refer to the following drawings for model specific dimensions mounting locations and throw distance information ...

Страница 14: ...QUIRED TO ACCOMMODATE AIRFLOW ADJUSTER RANGE CABLE ROUTING PD1 PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38 GFX208 01 PD1 69 x W 67 W WIDTH OF THE PROJECTED IMAGE EXAMPLE FOR 50 DIAGONAL IMAGE PD1 69x40 67 28 27 PD2 PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38 GFX209 01 PD2 1 15 x W 1 18 W WIDTH OF THE PROJECTED IMAGE EXAMPLE FOR 50 DIAGONAL IMAGE PD2 1 15x40 1 18 44 82 FOR REFERENCE ONL...

Страница 15: ...QUIRED TO ACCOMMODATE AIRFLOW ADJUSTER RANGE CABLE ROUTING PD1 PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38 GFX208 01 PD1 PD1A PD1B 69 x W 16 32 W WIDTH OF THE PROJECTED IMAGE EXAMPLE FOR 50 DIAGONAL IMAGE PD1 69x40 16 32 43 92 PD2 PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38 GFX209 01 PD2 PD2A PD2B 1 15 x W 14 47 W WIDTH OF THE PROJECTED IMAGE EXAMPLE FOR 50 DIAGONAL IMAGE PD2 1 15x40 1...

Страница 16: ...DTH OF THE PROJECTED IMAGE EXAMPLE FOR 50 DIAGONAL IMAGE PD2 1 15x40 4 09 41 91 FOR REFERENCE ONLY DIMENSIONS IN INCHES ADJUSTER POSITION IS IN NOMINAL PD IS SUBJECT TO TOLERANCE VARIATION OF 5 STAY OUT ZONE REQUIRED TO ACCOMMODATE AIRFLOW ADJUSTER RANGE CABLE ROUTING PD1 PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38 GFX210 01 PD1 69 x W 2 24 W WIDTH OF THE PROJECTED IMAGE EXAMPLE FOR 50 DIAGO...

Страница 17: ... 5 STAY OUT ZONE REQUIRED TO ACCOMMODATE AIRFLOW ADJUSTER RANGE CABLE ROUTING PD1 PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38 GFX210 01 PD1 PD1A PD1B 69 x W 18 76 W WIDTH OF THE PROJECTED IMAGE EXAMPLE FOR 50 DIAGONAL IMAGE PD1 69x40 18 76 46 36 PD2 PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38 GFX211 01 PD2 PD2A PD2B 1 15 x W 16 91 W WIDTH OF THE PROJECTED IMAGE EXAMPLE FOR 50 DIAGONAL ...