2.00
15.57
15.99*
13.48*
2.50
STAY OUT ZONE
4.83
2.50
1.75
17.05*
2.35* 38-GFX208-01
1.75* 38-GFX209-01
STAY OUT ZONE
4.436*
PD1**
PD2**
2.087*
10.63
.750
SLOT TYP.
.375
SLOT TYP.
32.53
.488 TYP.
.50 TYP.
4X MOUNTING SLOT
PD1: PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38-GFX208-01
PD1 = .69 x W" + .67"
W: WIDTH OF THE PROJECTED IMAGE
EXAMPLE: FOR 50" DIAGONAL IMAGE, PD1 = .69x40"+.67" = 28.27"
PD2: PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38-GFX209-01
PD2 = 1.15 x W" - 1.18"
W: WIDTH OF THE PROJECTED IMAGE
EXAMPLE: FOR 50" DIAGONAL IMAGE, PD2 = 1.15x40"-1.18 = 44.82"
FOR REFERENCE ONLY
DIMENSIONS IN INCHES
* ADJUSTER POSITION IS IN NOMINAL
** PD IS SUBJECT TO TOLERANCE VARIATION OF 5%
STAY OUT ZONE REQUIRED TO ACCOMMODATE
- AIRFLOW
- ADJUSTER RANGE
- CABLE ROUTING
PD1: PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38-GFX208-01
PD1 = .69 x W" + .67"
W: WIDTH OF THE PROJECTED IMAGE
EXAMPLE: FOR 50" DIAGONAL IMAGE, PD1 = .69x40"+.67" = 28.27"
PD2: PROJECTION DISTANCE FROM MOUNTING LOCATION FOR 38-GFX209-01
PD2 = 1.15 x W" - 1.18"
W: WIDTH OF THE PROJECTED IMAGE
EXAMPLE: FOR 50" DIAGONAL IMAGE, PD2 = 1.15x40"-1.18 = 44.82"
FOR REFERENCE ONLY
DIMENSIONS IN INCHES
* ADJUSTER POSITION IS IN NOMINAL
** PD IS SUBJECT TO TOLERANCE VARIATION OF 5%
STAY OUT ZONE REQUIRED TO ACCOMMODATE
- AIRFLOW
- ADJUSTER RANGE
- CABLE ROUTING
SIZE
PART NUMBER
ISSUE
B
38-GFX20X-01, Direct 01
SCALE
MASS
1:8
33.36 LBS[15.13 KG]
SHEET
1
OF
1
NOT TO BE DISCLOSED OR REPRODUCED IN ANY
MANNER WITHOUT THE EXPRESS WRITTEN
PERMISSION OF CHRISTIE DIGITAL SYSTEMS INC
PROPRIETARY
809 WELLINGTON STREET NORTH
KITCHENER, ONTARIO, CANADA
N2G 4Y7