26
TroUBlesHooTiNg
Q6 Auto Calibration and Auto Touch Area Setting both failed?
A:
Configuration
Aspect Ratio
Auto
Phase
Clock
H. Position
V. Position
Digital Zoom
V. Keystone
Orientation
Front Ceiling
Back
Enter
Select
1. Check the “Ceiling Mount” OSD setting first. The interactive
function supports Ceiling Mode only
When projector OSD message is shown, this may result in failure
to Auto Calibration and Auto Touch Area Setting. Wait until OSD
message is gone before performing Auto Calibration and Auto
Touch Area Setting.
VGA
1280X720 60Hz
Follow the troubleshooting steps below to perform Auto Calibration
and Auto Touch Area Setting again.
a. Exit all software applications.
b. Reduce ambient light.
c. Do not obstruct or shake lens while setting up Calibration
d. Check if the projection image is clear. If not, adjust focus to
sharpen the image.
e. If the “Auto Touch Area Setting failed” or "Auto Calibration
failed" message pops up on screen again, switch to Manual
Mode to do Touch Area Setting and Calibration.
2. Check Laser Power Mode selection Lower brightness (ECO
mode) may affect both Auto Touch Area Setting and Auto
Calibration. Switch to Normal mode to complete Touch Area
Setting and Calibration.
Captiva Touch User Manual