Select Digital zoom +. The On-Screen Menu disappears and
“D. zoom +” appears. Press the SELECT button to expand the
image size. Use the Point
ed7 8
buttons to pan the image.
The Panning function can work only when the image is larger
than the screen size.
You can also enter the Digital zoom + mode by pressing the
D.ZOOM button on the remote control.
Digital zoom +
Select Digital zoom –. The On-Screen Menu disappears and
“D.Zoom –” appears. Press the SELECT button to compress the
image size.
You can also enter the Digital zoom – mode by pressing the
D.ZOOM button on the remote control.
To exit the Digital Zoom +/– mode, press any button except the
D.ZOOM , SELECT, and Point buttons.
Digital zoom –
For zooming in and out the images
Keystone
This function is used to store or reset the keystone correction
when the AC power cord is unplugged. Use the Point
7 8
buttons to switch between each option.
Store. . . Keep the keystone correction even when the AC
power cord is unplugged.
Reset . . Release the keystone correction when the AC power
cord is unplugged.
To correct keystone distortion, press the Select button. The
Keystone dialog box appears. Use the Point
ed7 8
buttons to
correct keystone distortion. (p.29)
Ceiling
Rear
Ceiling
When this function is set to “On,” the picture is top/bottom and
left/right reversed. This function is used to project the image
from a ceiling-mounted projector.
Rear
When this function is set to “On,” the picture is left/right
reversed. This function is used to project the image from the
rear of the screen.
Reset
This function returns all adjusted values to the factory default
settings. Press the SELECT button at Reset to display a
confirmation box. To reset, press the SELECT button at “Yes.”
SCREEN MENU
Move the red frame pointer to the desired
function and press the SELECT button.
Computer Input
Exit the Screen Size Adjustment Menu.
Quit
✔
Note:
• The panning function may not operate properly if
the stored Mode in the PC Adjust Menu is used.
(p. 36)
•The minimum compression ratio can be limited
depending on the input signal or when the
Keystone function is working.
• Digital zoom +/– cannot be selected when Full
screen or True is selected.