E461755
6
C
C
C
L
L
L
M
M
M
1
1
1
0
0
0
0
0
0
0
0
0
2.3.2.
Display of the CLM1000-Standard
Display
Mode of
operation
Range
Meaning
Real power]
0,0 - 4224 Watt
Instantaneous real
power of the consumer.
Active energy
[kWh]
(consumption)
Time [h]
0,0000 - 99999,99
kWh
00:00 –
9999:59 h
Energy since begin the
measuring.
Time since begin the
measuring.
Cost [€]
Time [h]
0,00 - 99999,99 €
00:00 - 9999:59 h
Costs since begin the
measuring.
Time since begin the
measuring.
Active energy of
24h measuring
[kWh]
Cost of 24h
measuring [€]
0,0000 - 108,0000
kWh
0,00 - 99999,99 €
24 hour measuring runs!
The display backlight is
green if the 24 hour
measuring is ready und
the result is shown.
Voltage [V]
Current [A]
100,0 - 264,0 V
0,000 - 16,00 A
Instantaneous voltage.
Instantaneous current.
Max. voltage [V]
Min. voltage [V]
100,0 - 264,0 V
100,0 - 264,0 V
Maximum voltage of
the measuring.
Minimum voltage of the
measuring.
RESET
1(9)
WATT
35.9
RESET
2(9)
kWh
0.0238
00:39
h
RESET
3(9)
€
2,05
00:39
h
- - -
- - -
- - -
4(9)
KWh/24h
€/24h
- - -
RESET
5(9)
VOLT
233.6
0.201
AMPERE
RESET
6(9)
Vmax
233.9
231.0
Vmin