9
E461755
4.
Technical data
4.1
CLM1000 variant types and measurings
CLM1000
H=Home
S=Standard
P=Professional
Modes
Range
Resolution
H
S
P
Real power
0,0 - 4224 W
0,1 W / 1 W
●
●
●
Real power (min/max)
0,0 - 4224 W
0,1 W / 1 W
●
●
Apparent power
0,0 - 4224 VA
0,1 VA / 1 VA
●
Reactive power
0,0 - 4224 var
0,1 var / 1 var
●
Active energy
(consumption)
0,0000 - 99999,99 kWh
0,0001 - 0,01 kWh
●
●
●
Active energy / 24 h
(consumption / 24 h)
0,0000 - 108,0000 kWh
0,0001 kWh
●
●
Apparent energy
0,0000 - 99999,99 kVAh 0,0001 - 0,01 kVAh
●
Reactive energy
0,0000 - 99999,99 kvarh 0,0001 - 0,01 kvarh
●
Consumption costs
0,00 - 99999,99 €
0,01 €
●
Consumption costs
/ 24 h
0,00 - 99999,99 €
0,01 €
●
Tariff
0,000 - 99,999 €
0,001 €
●
Testing time
00:00 - 9999:59 h
1 Minute
●
●
●
% ON (threshold
measuring)
0,0 - 100,0 %
0,1 %
●
●
Voltage
100,0 - 264,0 V
0,1 V
●
●
Voltage (min/max)
100,0 - 264,0 V
0,1 V
●
●
Current
0,000 - 16,00 A
0,001 A / 0,01 A
●
●
Current (min/max)
0,000 - 16,00 A
0,001 A / 0,01 A
●
●
Load recognition
resistance, capacitance, inductance
●
Power factor
0,000 - 1,000
0,001
●
Data logger
(option)
●
USB interface
(option)
●