Installation
18
Loop Components Installation
The following will provide guidelines for the installation, beginning at Intake Cup location and proceeding in the
direction of auger travel.
Suspended Systems
: Measure and mark the trough so that when it is installed, the joint with the next trough
will be located directly below a suspension drop line.
Intake Cup and Elbows Installation
1.Attach an Elbow
(Item 2)
to the Intake Cup
(Item 1)
using a Tube Coupling
(Item 3)
as shown
.
2.Cut Elbows to length to achieve desired width.
Note: 44" [111.8cm] Minimum Center to Center loop width.
Important! Cut the same amount off of each Elbow and leave a minimum 2" of straight. (See Figure 14.)
3.If extra width or length is needed, add a straight piece of Pipe
(Item 4)
. and an extra 2" Tube Coupling.
Clean-Out Installation
1.Install a Clean-out
(Item 1)
between the Elbow and the End Cap
using Tube Couplings
(Item 2) as shown.
2.Install a Clean-out Lock
(Item 3)
as shown
.
Feed Flow Direction
Feed Flow Direction
1
2
2
Leave 2" [5.1cm] of Straight Minimum.
Cut equal amounts from each Elbow.
Item
Description
Part No
1
2" Tube Coupling
48722
2
ULTRAFLO Steel Elbow
9639
3
Clean-Out
13405
4*
35.92" Straight Tube (If needed)
13269
4
*
Figure 14.Intake Cup & Elbows Installation
1
44" [111.8cm] Center
to Center Minimum.
Figure 15.Clean-out Installation
Item
Description
Part No
1
2" Tube Coupling
48722
2
Clean-Out
13405
3
Clean-Out Lock Kit
57375
3
2
1
1