background image

Product Specifications

 

28

  

 

 

 

 

Product Name 

chlor

Organo

 (AL-790A) 

Category 

Acidulous 

(organochlorine)

 water generator 

Rated voltage and frequency 

120 VAC 60Hz 

Rated current 

0.8 A 

External dimensions

    

(Includes projections) 

10.24 in W x 14.21in H x 4.72 in D 
(260 mm W x 361 mm H x120 mm D) 

Net Weight 

Approx. 8.8 lbs. (Approx. 4.0kg) 

Water supply quality 

Tap water 

Operating water pressure range 

14.5 psi to 101.5 psi (0.1 ~ 0.7MPa) 

Water temperature 

32°F - 95°F (0°C - 35°C) 

Operating ambient temperature 

32°F - 104°F (0°C - 40°C) 

Use relative humidity 

85% RH or less (no condensation) 

Dispense amount (water flow amount) 

Approx. 0.7 gallons/min (2.6L/min) 

Electrolyte auxiliary solution 

Dedicated electrolyte auxiliary solution 

Electrolyte auxiliary solution storage tank 
capacity 

Approx. 17 liquid ounces (500mL) 

Available Free Chlorine Concentration 

30 - 50 ppm (Reference value) 

Concentration setting 

5-step selection formula 
Range 1 (30 ppm) - Range 5 (50 ppm) 

Dispensing start switch 

Proximity sensor (non-contact type), 
dispensing button 

Dispensing time setting 

Configurable in the range of 10 to 120 
seconds 

Dispensing amount setting 

Configurable in the range of 1 to 200 L 

 

 

Life of consumables 

Pump: 1,600 hours* 
Electrolytic cell: 800 hours* 

*When the setting is range 3. 

Approximately, depending on the quality 
of the water supply. 

Содержание AL-790A

Страница 1: ...Version 1 1 June 2021 Instructions for Use NaCl Acidulous Generator Model AL 790A chlorOrgano Functional Electrolyzed Water ...

Страница 2: ...fully and use the product accordingly Read Safety Precautions Pages 4 through 9 before using the device for a safe operation Keep this manual in a secure place and continue to refer to it for safe operation and proper maintenance We are not responsible for product failure due to improper installation and or use IMPORTANT DO NOT DISCARD ...

Страница 3: ...anel Features 12 Setting Panel 13 How to Install 14 How to Set for Operation 15 How to Use 18 How to Replenish the Auxiliary Solution 20 How to Measure the Chlorine Concentration 22 How to Clean 23 How to Wall Mount 24 How to Troubleshoot 26 Product Specifications 28 Warranty Card 29 ...

Страница 4: ... when operating the device can lead to a possibility of imminent death or serious injury WARNING Not following the content of this label when operating the device can lead to a possibility of death serious injury and or damage to the device and property NOTE Not following the content of this label when operating the device can lead to a possibility of injury and or damage to the device and propert...

Страница 5: ...n may cause an electric shock or fire Do not use a damaged plug or insert into a loose power outlet If the device is accidentally dropped into water unplug if from the power outlet first and then touch the device otherwise it may cause an electric shock Consult your dealer for repair Remove dust dirt or other types of foreign material accumulated in the power plug regularly they can cause a fire U...

Страница 6: ...e is higher than 104 F 40 C Areas that are closed with poor ventilation Areas that are likely to freeze Areas where water falls directly on the device Areas where there is a high salt concentration in the air Place the device on a level surface that is free from vibration and shock Ensure that the surface is fixed firmly in place so that it does not fall or tip over otherwise injury and or damage ...

Страница 7: ...5 F 0 C to 35 C Freezing or hot water may cause deformation or breakage of resin parts and result in a device failure Water Supply Hose or Pipe A bend kink or any other defects in the water supply hose or pipe may cause a water leak or malfunction check the water supply hose before turning on the tap Water Supply Control The tap or faucet of tap water is the mechanism for controlling the water sup...

Страница 8: ...g so can result in production of toxic and harmful substances and toxic gases that can be life threatening DO NOT mix Dedicated electrolyte auxiliary solution is an acidic liquid containing NaCl sodium chloride Never mix it with any other aqueous solutions DO NOT drink DO NOT drink dedicated electrolyte auxiliary solution If accidentally ingested drink plenty of water ...

Страница 9: ...a container keep the air in the container to a minimum and keep the container in a cool and dark place In addition it may deteriorate due to long term storage and the desired effect may not be obtained Therefore be sure to measure and confirm the effective available free chlorine concentration before use ...

Страница 10: ...ies A Electrolyte Solution Storage Tank Cover B Digital Display C Proximity Sensor D Dispensing Hose E Control Panel F Power Switch G Setting Panel Cover Door H Dispensing Hose Head I Water Inlet J Electrical Plug Three pronged K Wall Hook Attachment Hole 3 Places ...

Страница 11: ...able Dispensing Hose Set Instruction for Use Accessories Optional Wall Hook Set Dedicated Electrolyte Auxiliary Solution NOTE Inlet hose can be obtained separately from a local hardware store Select a hose that fit the mating and water supply pressure requirements The water inlet is G 1 2 male thread ...

Страница 12: ...Control Panel Features 12 Digital Display Proximity Sensor Fixed Dispensing Lamp Fixed Dispensing Solution Refill Lamp Button ...

Страница 13: ...Setting Panel Features 13 Setting Button Up Button Child Lock Button Down Button Error Reset Button Solution Refill Button Press PUSH on the cover door to gain access to the Setting Panel ...

Страница 14: ...Straight Dispensing Hose Water Inlet Strainer NOTE The water inlet is G 1 2 male thread Be sure to attach the included inlet strainer to the water inlet NOTE Consult your dealer for questions related to installation Observe local regulations when disposing of unused accessories packaging materials and products at the end of life ...

Страница 15: ... dispensing amount and dispensing time press up each time to increase the level by one and press down each time to decrease the level by one If either button is held for more than 0 5 seconds it becomes level 10 or level 10 the maximum levels respectively For the concentration range the range moves up and down from 1 to 5 each time it is pressed Refer to Estimate of Effective Chlorine Concentratio...

Страница 16: ...ng amount mode Press the SET button to toggle through different modes of display Press the SET button repeatedly until the lamp L lights up on the Digital Display Press Up or Down to set the desired dispensing amount in liters L Setting by Dispensing Time Press the SET button repeatedly until the lamp SEC lights up on the Digital Display Press Up or Down to set the desired dispensing time in secon...

Страница 17: ...e 17 NOTE The actual effective available free chlorine concentration levels vary depending on the tap water used as well as volume of tap water feed Generation Range Level Effective Chlorine Concentration r 1 30 ppm r 2 35 ppm r 3 40 ppm r 4 45 ppm r 5 50 ppm ...

Страница 18: ...over the Proximity Sensor to dispense for a preset time seconds While dispensing hold a hand over the Proximity Sensor again or press the DISPENSE button to stop dispensing E Press to dispense in the set amount The DISPENSE lamp blinks during dispensing Press again to stop dispensing Note When the child lock is activated the DISPENSE lamp turns off and the DISPENSE button cannot be operated F Solu...

Страница 19: ...pensing hold a hand over the Proximity Sensor D again for 0 5 seconds or press the DISPENSE button E To Dispense with DISPENSE Button Manual Method Press the DISPENSE button E to start dispensing water from the dispensing hose The Digital Display A displays the remaining water amount in liters L and stops automatically at 0 liters L To stop dispensing manually while dispensing hold a hand over the...

Страница 20: ...ry solution storage tank cover on the top of the device slightly to the right and then lift it from the body Auxiliary Solution Storage Tank Cover 2 Turn the electrolyte auxiliary solution storage tank cap counterclockwise to remove it 3 Remove the cap of the container containing the NaCl electrolyte auxiliary solution and replenish the NaCl electrolytic auxiliary solution to the storage tank Take...

Страница 21: ...it in place Align to the triangle mark 6 If the solution REFILL lamp continues to blink press the REFILL button on the Setting Panel if everything is in order the solution REFILL lamp will turn off CAUTION Refill with care to prevent an overfill of the NaCl electrolyte auxiliary solution Wipe anyoverflow with a dry cloth Dispose empty containers of the NaCl electrolyte auxiliary solution in accord...

Страница 22: ...nwanted variation Collect about one 1 cup of water 2 Soak the tip of the effective chlorine concentration measurement paper in the product water collected 3 Check the available free chlorine concentration by comparing the available free chlorine concentration measurement paper with the colorimetric table under abright light CAUTION As time passes the color of the colored measuring paper changes Co...

Страница 23: ...ning or otherwise If water gets inside the device it may cause a short circuit resulting in a device failure electric shock or fire Automatic Cleaning Function The device performs automatic cleaning function after a certain period of use to remove the dirt collection in the inside of the electrolytic cell How to Clean the Main Body When cleaning the main body exterior and dispensing hose use a sof...

Страница 24: ... structural condition of the wall appears to be sufficiently bad that there is a risk that the device may fall off 1 Thoroughly clean and dry the wall surface before installation If dirt or oil remains the adhesion of the double sided tape may not be at its full strength 2 Peel off the double sided tape protective cover from the wall hook ensure it is at level as shown locate it on a clean wall wi...

Страница 25: ... the case of tiles locate the nails in the mortar joints between the tiles 4 Remove the covers of the wall hook mounting holes on the back of the device and hang it on the wall hook Ensure that the device is securely supported by the wall hook on all three attachment holes ...

Страница 26: ...a long time the electrolytic cell deteriorates and its electrolytic capacity decreases resulting in generated water with less concentration than the device is set for Contact your dealer for repair Dispensing amount decreases E 1 on Digital Display Water inflow drops abnormally below the rate of 0 34 gal min 1 5 L min Cut off the water supply turn off the switch disconnect the power plug from an o...

Страница 27: ... the power supply Over current indication occurs when an excessive electrolytic current is detected Contact your dealer with the error code for a repair Press the error RESET button to stop the error sound and cancel the error message on Digital Display once C 1 and normal display alternates on Digital Display during standby The problem indicates a possible replacement of the pump Contact your dea...

Страница 28: ...ondensation Dispense amount water flow amount Approx 0 7 gallons min 2 6L min Electrolyte auxiliary solution Dedicated electrolyte auxiliary solution Electrolyte auxiliary solution storage tank capacity Approx 17 liquid ounces 500mL Available Free Chlorine Concentration 30 50 ppm Reference value Concentration setting 5 step selection formula Range 1 30 ppm Range 5 50 ppm Dispensing start switch Pr...

Страница 29: ...hin the date of purchase present this page to your dealer for a repair Customer Name Address Phone Number Sales Outlet Name Palm Beach Springs Water Company Inc Address 1551 NW 24th Dr Bay B Okeechobee Florida 34972 USA Phone Number 561 693 9015 Product Name chlorOrgano model AL 790A Category NaCl Acidulous Water Generator Serial Number Warranty Period Ends Main body 1 year from the purchase date ...

Страница 30: ... user errors failures caused by other devices or failures and damage due to improper repair or modification D If the repair is required because of failure and damage due to mishandling after purchase E If the repair is required because of failure and damage due to disasters earthquakes storms floods lightning strikes pollution salt damage abnormal voltage and other catastrophes F If the repair is ...

Отзывы: