SELF-CONTAINED BREATHING APPARATUS (CTS-IB-PPE-01)
©Chlorine Tech Services (Pty) Ltd
–
CIPC Reg # 2018/101848/07
Rev # 01/2020/10/15
P a g e
| 10
Step 3
•
Place the face mask, via strap, around
neck
•
Grasp the ends of the pull-down
adjustment shoulder straps
•
Pull the straps downwards towards your
hips until waist belt pad aligns with hips
•
Adjust the SCBA into position (top of
cylinder should be neck high)
Step 4
•
Connect waist belt buckle
•
Pull adjusting straps (as shown) until
device is secure
•
Adjust the waist (weight) belt to suit the
weight of the SCBA which should rest
comfortably on your hips
•
Tuck strap loose ends into belt
Step 5
•
Press
RED
LDV button (Fig 4) to switch
off positive pressure
Step 6
•
Fully open the cylinder valve (slowly) to
pressurise the system
•
Check the pressure gauge (should read
between 250/300 bar)