manualshive.com logo in svg
background image

 
 

USER’S INSTRUCTIONS

 

IST-USO-0905093 

Rev. 2 – 20/09/2016 

IDP 109 

Page 1 of 2

 

 

K80E T8N – K80E T8A 

 

POWERED AIR PURIFYING RESPIRATORS 

 

Respirator composition chart: 

Respirato

Part # 

Code 

Helmet 

Blower 

unit 

Cartridge/

Filter

 

Battery 

Battery 

charger 

Cord 

Breathing

tube 

Airflow 

indicator 

Belt 

 

NIOSH 

APPROVAL 

 

 

 

 

 

 

 

 

 

 

 

 

0313083 

K80E 

0302021

 

T8N 

0303038

 

2 X ZA2P3 

0601019

 

6V6Ah 

0309064

 

BP-6 

0105086 

0309081 

0309095 

0806008 

0307020 

 

TC-23C-1572 

0313084 

K80E 

0302021

 

T8A 

0303040

 

2 X ZP3 

0601023 

6V6Ah 

0309064

 

BP-6 

0105086 

0309081 

0309095 

0806007 

0307020 

TC-21C-627 

 

1. 

DESCRIPTION 

1.1a K80E HELMET: It is composed of: a fiberglass shell covered with 3 coats of paint, 

the last one of which, the most external one, is polyurethane; a polycarbonate visor; 
a  polyamide  collar  which  closes  efficiently  and  comfortably  round  the  operator's 
neck; a head-band adjustable from 53 to 63 cm (6-5/8 to 7-7/8 hat size). 

1.2a T8A  and  T8N  BLOWER  UNITS:  They  are  composed  of:  an  ABS  case  with  socket 

and ON/OFF switch. A fan unit actuated by an electric micro motor. 

1.3  BREATHING  HOSE  ASS.Y:  It  is  composed  of  an  ethyl  vinyl  acetate,  convoluted 

hose with pivot couplings for helmet-blower unit coupling. 

1.4  BATTERY  ASSEMBLY:  It  is  composed  of:  a  sealed 6V6Ah rechargeable lead-acid 

battery. 

1.5  BP-6  BATTERY  CHARGER:  It  is  composed  of:  a  stabilized  battery  charger  with 

electric cord. 

1.6  CARTRIDGES/FILTERS/CARTRIDGES: 
 

a) ZP3 (HE) FILTER (0601023): made of finely pleated technical paper. 
b)  ZA2P3  (HE/OV)  CARTRIDGE  (0601019)  The  first  section  is  composed  of  finely 
pleated  technical  paper.  The  second  section  of  activated  carbon.  Both  parts  are 
packed into a single plastic housing with covers and seals. 

1.7  AIRFLOW  INDICATOR:  It  is  composed  of  a  transparent  tube  with  indicator  ball 

inside. The indicator is needed to check the airflow performance of the respirator it is 
supplied with, before each use. 
 

2.  TECHNICAL CHARACTERISTICS 

2.1  K80E HELMETS: 
Shell : Fiberglass  - Face shield : Polycarbonate – Head suspension: Polyethylene – Face 
shield gasket: polyethylene foam. 
Noise level < 80dB. 
 
2.2  BLOWER UNITS: 

Type of unit 

Type of 
filter 

N.of 
cartridg
es/filters 

Voltage 
 
 
Volts 

Airflow at 20°C  
60% R.H .-
Battery fully 
charged 
Lpm 

Expected life of 
micro motor  
 
Hours 

T8A 
0303040 

ZP3  

HE filter 

>170 

1400 

T8N 

0303038 

ZA2P3 
HE/OV 

cartridge 

>170 

700 

 
 
2.3  BATTERY ASSEMBLY: 

Type of 
blower 
unit 

Type of 
battery 

Battery   
P/N 

Voltage 
 
 
- Volts 

Terminal 
voltage 
under load 
- Volts 

Running 
time at 
20°C  
- Hours 

Approx.
battery 
life 

T8A 
0303040 
 
T8N 
0303038 

Rechargeable 

Lead acid 

0309064 

6V  6Ah 

5.1 

>4 

2 years 

or 

300 

cycles 

 

- Self discharge: 50% of its capacity  

in 6 months at 40° C 
in 16 months at 20° C  

 
2.4  BATTERY CHARGING: 

Type of blower 

unit 

Charger Model 

INPUT 

OUTPUT 

Charging time 

Hours 

T8A 
(0303040) 
 
T8N 
(0303038) 

BP-6 

0105086 

110V 50/60Hz 

 

7V 

900mA

 

 8 

 
 
 
 

2.4a  ZP3 HE FILTER (0601023): 

HE – High Efficiency Particulate Air filter for powered, air-purifying respirators. 

(See 

also label and Users’ Instructions packed with filter)

When the HEPA filter is exhausted, an increase in drop pressure is registered on the 
filter. This is indicated by a progressive diminishing of the airflow inside the 
respirator. 

2.4b  ZA2P3 HE/OV CARTRIDGE (0601019): 

The ZA2P3 combined cartridges are permitted for respiratory protection against 
organic vapors and particulates at a high efficiency level. 
 
Before occupational use of these cartridges the employer shall implement a cartridge 
change schedule based on objective information or data that will ensure the 
cartridges are changed before the end of their service life (as per requirements of the 
OSHA 1910.134 Respiratory Protection Standard). 
 
Time use limitations:  
Replace cartridges in accordance with an established change schedule or earlier if 
smell, taste or irritation from contaminants is detected and, in any case, prior to the 
expiry date indicated on the label affixed to the cartridge. 

 (See also label and User’s Instructions packed with filter). 

 

IN CASE OF DOUBT REGARDING THE TYPE OR EFFICIENCY OF THE 
CARTRIDGES/FILTERS AND CARTRIDGES CONTACT KASCO AT 

[email protected]

 

 

3.  OPERATION 

3.1  The  blower  unit,  powered  by  rechargeable  battery,  takes  in  air  through  the 

cartridges/filters and sends it, via hose, to the inside of the helmet. The helmet goes 
into slight positive over pressure and the wearer breathes filtered air only. Expired air 
is expelled through the diaphragm valves. 

 

4.  USE 

4.1 For the protection of the eyes and respiratory system of the wearer while working in 

non I.D.H.L. environments containing dusts, fumes, mists and organic vapors.

 

 

4.2  LIMITATIONS (FOR RESPIRATORS EQUIPPED WITH ZA2P3 (HE/OV) 
CARTRIDGES) 

a) Do not use in atmospheres immediately dangerous to life or health. 
b) Do not wear for protection against organic vapors with poor warning properties. 
c) Do not wear for protection against organic vapors which generate high heats of 
reaction. 
d) Max. use concentration shall be lower than the max. concentrations listed on the 
User’s  Instructions  sheet  packed  with  the  filter,  where  that  concentration  produces 
atmospheres immediately dangerous to life or health. 
e) Do not use with fumigants. 
f) Do not use in closed environments (tanks, silos etc.). 
g) Do not use in atmospheres containing less than 19.5 % oxygen. 
h) Do not use for protection against Carbon monoxide (Co) or natural gas. 
i)  Do not use in explosive atmospheres. 

4.3  LIMITATIONS (FOR RESPIRATORS EQUIPPED WITH ZP3 (HE) FILTERS 

a) Do not use in atmospheres immediately dangerous to life or health. 
b) Do not use for protection against vapors, gas and pesticides. 
c) Do not use in closed ambient (tanks, silos etc.). 
d) Do not use for fire fighting. 
e) Do not use in atmospheres containing less than 19.5% oxygen. 
f) Do not use in explosive atmospheres. 
 

5.  OPERATING INSTRUCTIONS 

5.1   6V6Ah BATTERY RECHARGING: 

 

Plug the battery charger into mains. 

 

Connect battery charger outlet plug to the discharged battery. 

 

Battery recharging is automatic (RED Led).

 

Led turns GREEN when about 90% 

charged. 

 

The battery charger may remain plugged into the fully charged battery with no 
overcharge risk provided it is energized. 

CHARGE BATTERY WITH THE SUPPLIED BATTERY CHARGER ONLY. 
 
 
 

5.2  BATTERY AND BLOWER UNIT SET-UP 

Отзывы: