SELF-CONTAINED BREATHING APPARATUS (CTS-IB-PPE-01)
©Chlorine Tech Services (Pty) Ltd
–
CIPC Reg # 2018/101848/07
Rev # 01/2020/10/15
P a g e
| 11
Step 7 (Method 1)
•
Holding the facemask as shown, place
over head with centre plate at the back
•
Place chin in facemask chin cup
•
Tighten chin (lower) straps
•
Tighten cheek (upper) straps
•
Tighten centre (head) strap if necessary.
Step 7 (Method 2 - preferred)
•
Holding the facemask as shown
•
Place chin in facemask chin cup and pull
head harness over the head
•
Tighten chin (lower) straps
•
Tighten cheek (upper) straps
•
Tighten centre (head) strap if necessary.
Step 8
•
First breathe will switch on LDV to positive
pressure mode
•
Inhale and hold breath
– there must be no
leak (audible)
•
Breathe normally and expelled air should
pass free through exhalation valve
•
Check supplementary air supply is
working by pressing centre button on LDV
– then release
Step 9
•
Check that a strong air flow is heard
when two fingers are inserted between
the sealing edge and face
•
Check that the pressure on the pressure
gauge reads full