Chapter 5
Maintenance and Checkup
CMN015-005
原本
(Original instructions)
59
5.1.3
Maintenance of primary filter
(When everything is pulled up together
)
1.
Pull out the primary filter chamber.
When the handle of the filter attachment
plate is lifted, you can remove the filter
mounting plate and the primary filter
sets.
2.
Clean the upper section of the seal and
the area of the filter mounting plate in
contact with the seal.
5.1.4
Cleaning the dust tray
IMPORTANT
Do not let dust accumulate in the dust tray. It may cause clogging of the primary
filter.
Dispose of dust after use.
1.
Release two latches only of the dust tray.
(
There are also latches on the other
side.
)
2.
Attach the wrench and raise the main unit
above the dust tray by more than 30mm.
3.
Pull out the dust tray and clean it.