The malfunction code:
P7
(
The
outdoor unit DC generatrix voltage is abnormal)
The malfunction code
:
P8
(lack the refrigerant or reverse valve fault)
2、
check whether module temp sensor’resistance is
normal (the normal value range:1~40KΩ);
3、
check whether the module and radiator are firm;
4、
check whether the disperse heat silica gel is
short or dry;
5、
check whether the module has been damaged.
N
1、Change the temp sensor;
2、Firm the module and radiator;
3 、 Append anew the disperse heat
silica gel;
4、Change the module。
Y
Please change the outdoor PCB
Turn off the supply
Check whether the power voltage is in the
normal voltage range “150V~270V”。
N
Ensure the power voltage is in the
normal voltage range“150V~270V”
Y
The IPM basic board hardware has been
damaged
,
pls change the IPM basic board
。
Turn off the power
Check whether the high and low pressure
valve are open
N
Open the high and low
pressure valve
正常
Check whether the system pressure is normal
(
the normal value
:
high pressure3.06Mpa low
pressure1.6Mpa
)
N
Due to refrigerant leakage
,
kook for the leak to weld it
,
then
charge anew the refrigerant to
the system.Fig.9
~
17
Pls change it if the sensor wire is short circuit
or open circuit.
Y
Y
The faulty cause
:
1
、
The power voltage is abnormal
2
、
The IPM basic board hardware
has been damaged
The faulty cause
1
、
the high and low pressure valve are closed
2
、
the refrigerant leaks from the A/C system
3
、
the indoor and outdoor pipe temp sensor are
loose or hang in the air.
4
、
the indoor and outdoor pipe temp sensor has
been damaged.
Содержание CMV-50V9A-S
Страница 1: ...DC Inverter Split Air Condition Unit SERVICE MANUAL ...
Страница 6: ......
Страница 8: ...The compressor s condensing pressure graph ...
Страница 12: ...Capacity Correction Factor Due to Tubing Length One Way Cooling Heating ...
Страница 13: ...Pressure Curve Suction Pressure Curve Discharge Pressure Curve ...
Страница 15: ...4 OUTLINE DIMENSION OF OUTDOOR AND INDOOR 4 1 Outline dimension of outdoor Units CMV 50V9A S CMV V64T9AD ...
Страница 18: ...5 The outdoor unit structure exploded view 5 1 The structure exploded view for CMV 50V9A S ...
Страница 19: ......
Страница 20: ...5 2 The structure exploded view for CMV V64T9AD ...
Страница 21: ......