N
Check whether the indoor and outdoor pipe
temp sensor are loose or hang in the air.
Pls arrange the indoor and
outdoor sensor correctly and
change it if the probe spring
piece is damaged.
Refer to Fig.18~25
Y
Fig. 11
、
the bell-mouth
should aim at the valve
port
Fig. 12
、
the bell-mouth
should aim at the valve
port
Fig. 9
、
please make
sure
that
there
is
enough soap bubble.
Warning
:
please connecting the indoor and outdoor units according to the correct installing method
,
Fig. 11~15
show the right operating way
;(
Note
:
the indicator pictures aren’t the real photos about the DC inverter dual
zone unit
)
Fig. 10
、
Pls daub the bubble to
four terminals, then observe them
for five minutes! If there are
some bubbles that grow slowly
and broke around the terminal,. it
shows the leakage