The 67
th
style indoor lamp panel
The timing lamp The turbo lamp The running lamp
The indoor unit faulty display:
Faulty contents
Trouble display
Communication fault
The running lamp lightens all the time,the turbo lamp
lightens 2 times ,and then extinguish 2 seconds。
Indoor fan fault
The running lamp lightens all the time,the turbo lamp
lightens 5 times,and then extinguish 2 seconds。
Indoor temp. sensor fault
The running lamp lightens all the time,the turbo lamp
lightens 3 times ,and then extinguish 2 seconds。
Indoor coil outlet temp. sensor fault
The running lamp lightens all the time,the turbo lamp
lightens 4 times,and then extinguish 2 seconds。
Indoor coil inlet temp. sensor fault
The running lamp lightens all the time,the turbo lamp
lightens 4 times ,and then extinguish 2 seconds。
Indoor coil middle temp. sensor fault
The running lamp lightens all the time,the turbo lamp
lightens 4 times ,and then extinguish 2 seconds。
Mode conflict
The running lamp lightens 1 time ,and then extinguish
1 second。
Defrosting or anti cold air
The timing lamp lightens 1 time ,and then extinguish
1 second。
The outdoor unit faulty display:
Faulty contents
Trouble display
the outdoor unit transducer module
protection faulty
The timing lamp lightens all the time,the turbo lamp
lightens 2 times ,and then extinguish 2 seconds。
over current of outdoor unit
The timing lamp lightens all the time,the turbo lamp
lightens 3 times ,and then extinguish 2 seconds。
discharge temp. of compressor too high,
outside ambient temp. too high, switch
temp. of compressor crust cut off, temp.
of module too high
The timing lamp lightens all the time,the turbo lamp
lightens 4 times ,and then extinguish 2 seconds。
The outdoor unit DC busbar voltage is
abnormal
The timing lamp lightens all the time,the turbo lamp
lightens 7 times ,and then extinguish 2 seconds。
lack refrigerant or reverse valve fault
The timing lamp lightens all the time,the turbo lamp
lightens 8 times ,and then extinguish 2 seconds。
outdoor sensor fault
The running lamp lightens all the time,the turbo lamp
lightens 7 times ,and then extinguish 2 seconds。
outdoor unit drive fault, start compressor
failure
The running lamp lightens all the time,the turbo lamp
lightens 6 times ,and then extinguish 2 seconds。
Содержание CMV-50V9A-S
Страница 1: ...DC Inverter Split Air Condition Unit SERVICE MANUAL ...
Страница 6: ......
Страница 8: ...The compressor s condensing pressure graph ...
Страница 12: ...Capacity Correction Factor Due to Tubing Length One Way Cooling Heating ...
Страница 13: ...Pressure Curve Suction Pressure Curve Discharge Pressure Curve ...
Страница 15: ...4 OUTLINE DIMENSION OF OUTDOOR AND INDOOR 4 1 Outline dimension of outdoor Units CMV 50V9A S CMV V64T9AD ...
Страница 18: ...5 The outdoor unit structure exploded view 5 1 The structure exploded view for CMV 50V9A S ...
Страница 19: ......
Страница 20: ...5 2 The structure exploded view for CMV V64T9AD ...
Страница 21: ......