6
Ampere and volt parameters are synergically adjusted by
means of knob
2
.
B
To carry out the gas test and the wire test se-
lect the corresponding symbol.
When you press the key
(test gas), the gas is released
from the welding torch for a
time period that is adjusted by
means of the key
30
; the
value is adjusted by means of
the knob
2
, from 1 to 60 sec-
onds. To interrupt the gas release press the key
again.
When you press the button
(wire test), the wire comes
out of the welding torch at a speed that can be adjusted by
means of the key
8.0
; the speed value, 1 to 22 meters/min-
ute, can be set using the knob
2
, and the key
must be
pressed for the whole duration of the test.
To return to the previous menu, press the key
.
C
Start stop.
To choose the welding start mode,
2T
,
4T
or
3L
, select
the corresponding symbol.
Mode 2T
.
The machine begins welding when the torch trigger is
pressed, and stops when released. With mode
2T
, you
can also choose the parameter
HSA
(Automatic Hot Start)
and the parameter
CRA
(Final Crater filler).
The 2 parameters
HSA
and
CRA
can be enabled at the
same time, or individually.
Once the parameter
HSA
has been enabled, the opera-
tor can adjust the
Start current
from 10 to 200% of the
welding current.
The
Current time
can also be adjusted from 0.1 to 10
seconds. The
Connection time
between the Start cur-
rent and the welding current can also be adjusted from 0.1
to 10 seconds. To adjust
Start current
values,
Current
time
and
Connection time
, enter
Main Menu
by select-
ing the key
F
MENU
and using the key
PARAMETERS
enter
the
process parameters menu
. Turn knob
2
to select
the parameter, press it to enter the regulation screen and
turn it to adjust the value.
Press that key
DEF
to reset
the manufacturer set parame-
ters.
After activating the param-
eter
CRA
, the operator can
adjust the
connection time
between the welding current
and the
crater filling current
(Crater Current) from 0.1 to
10 seconds. The operator can also adjust the
crater filling
current
from 10 to 200% of the welding current.
The duration of this current can also be adjusted from 0.1 to
10 seconds of the
Crater filling time
.
To adjust the values of
connection time
,
crater filling cur
-
rent
and
crater filling time
enter the main menu by select-
ing key
F
MENU
and enter the
process parameters
menu.
Turn knob
2
to select the parameter, press it to enter the
regulation screen and turn it to adjust the value.
Press the key
DEF
to reset the
factory set parameters.
Mode 4T.
To begin welding press and release the torch trigger; to
stop welding press and release it again. Together with
mode 4T
you may also select function
HSA
(automatic
hot start) and function
CRA
(final crater filling). (See
2T
Mode
).