background image

Installation Instructions

MSP-WRTIDSKY1 Skybox Kit

5

FLAT PANEL DISPLAY AND H BOX
INSTALLATION PROCUEDURES 

Flat Panel Display

WARNING:  Improper installation can cause serious per-
sonal injury!  Make sure that the structural members can 
support a redundant weight factor 

five times

 the total 

weight of the equipment you intend to support overhead.  
The structure must be reinforced before you install the Kit 
if the structure cannot support a redundant weight factor 

five times

 the total weight of the equipment.

NOTE:

  Items in parentheses () refer to parts shown in 

“PARTS” on page 6.

1. Install flat panel display on LCD mount brackets (20) and 

secure using four M4 X 10mm Phillips pan head screws (80) 
(see Figure 9).

2. With four screws securing LCD mount bracket and four screws 

securing display to LCD mount bracket loose, position display 
to desired location and height.

3. Tighten four screws securing LCD mount bracket and four 

screws securing display to LCD mount bracket.

H Box (Not Included)

1. Install H box bracket (not included) on LCD mount 

brackets (20) and secure using four 10-32 X 3/8” button-head 
cap screws (70) (see Figure 10).

  2. Install H box (not included) on H box bracket (not included) 

secure using four screws (not included) (see Figure 11).

button-head

 cap screws

 cap screws

button-head

Figure 9.  Flat Panel Display Installation

Figure 10.  H Box Bracket Installation

Figure 11.  H Box Installation

Содержание MSP-WRTIDSKY1

Страница 1: ... Kit which could affect or void the Factory warranty and to the equipment that will be attached to it thoroughly study all instructions and illustrations before you begin the installation Pay particu lar attention to the Important Precautions on Page 1 The maximum weight to be installed on the MSP WRTIDSKY1 is 40 pounds 18 14 Kg The spanning brackets are designed to fit above a conventional suspen...

Страница 2: ... is responsible for verifying that the structure to which the MSP WRTIDSKY1 s reinforcing plate is anchored will safely support the combined load of all attached components or other equipment WARNING The weight of the LCD displays must not exceed 40 lbs 18 14 kg the maximum load capacity of the rein forcing plate CAUTION To avoid personal injury or damage to the suspended ceiling kit be sure that ...

Страница 3: ...2 Installation Instructions MSP WRTIDSKY1 Skybox Kit DIMENSIONAL DRAWING ...

Страница 4: ...ee 1 4 split lock washers 60 and three 1 4 20 hex nuts 50 Do not tighten at this time see Figure 1 2 Remove the tiles from the area where mounting the kit 3 Install the span bracket assembly between the suspended ceil ing tile rails grid and expand the span bracket assembly until the brackets are flush with the rails see Figure 2 4 Tighten three 1 4 20 hex nuts 50 to secure span bracket assembly b...

Страница 5: ...le and loop its upper end around the ceiling truss Pull the tie wire tight and twist it around itself at least four times No additional anchor is required see Figure 7 Anchoring Procedure 1 Cut the 20 ft 6 1 m tie wire into four pieces of equal length WARNING Make sure the tie wire will not become loose Thread the end of the wire back through the first loop clos est to the eyebolt and bend the end...

Страница 6: ... panel display on LCD mount brackets 20 and secure using four M4 X 10mm Phillips pan head screws 80 see Figure 9 2 With four screws securing LCD mount bracket and four screws securing display to LCD mount bracket loose position display to desired location and height 3 Tighten four screws securing LCD mount bracket and four screws securing display to LCD mount bracket H Box Not Included 1 Install H...

Страница 7: ... Carriage 1 4 20 X 5 8 3 40 WASHER Flat 1 4 3 50 NUT hex 1 4 20 3 60 WASHER lock split 1 4 3 70 SCREW button head 10 32 X 3 8 16 80 SCREW Panhead M4 7 X 10mm 8 90 WIRE 14 gage 20 ft 6 1 m 1 100 ANCHOR concrete 4 110 SCREW lag eye 4 120 TURNBUCKLE 1 4 20 with hook and loop 4 130 KEY hex 1 8 1 10 20 30 40 50 60 70 80 90 100 110 120 130 ...