32
33
STERILISER WITH FEEDING
BOTTLE RACK
STERILISER WITHOUT
FEEDING BOTTLE RACK
STEP UP LINE
150 ML
-
4
250 ML
-
4
330 ML
-
4
WELLBEING LINE
150 ML
6
6
250 ML
6
6
330 ML
6
6
ANGLED
4
6
Note: DURING THE DISINFECTION CYCLE IT IS RECOMMENDED TO PLACE THE TEAT INSIDE ITS CAP RING, it is possible to use
the accessory rack by lying it against the WellBeing feeding bottles. The number of feeding bottles indicated in the chart refers to
bottles together with their rings and teats (cups are not included)
Chicco steriliser is guaranteed free of manufacturing faults for a pe-
riod of up to two years from the date of purchase (i.e. from the date
indicated on the retail receipt, or on other documents proving the
date of purchase).
This guarantee does not apply to components subject to normal
wear and tear.
ARTSANA reserves the right to modify at ant time and without prior
notice the contents of these instructions.
The reproduction, transmission, copying, as well as the translation
into another language, of any part of these instructions, are ab-
solutely forbidden without the previous written authorization by
ARTSANA.
IMPORTANT: If none of the solutions indicated above solves the problem, please contact Artsana Customer Service.
= Equipment certified and approved by IMQ (Ita-
lian Quality Brand)
= Equipment in compliance with the essential requi-
rements laid down in the EC Directives in force.
= WARNING!
= WARNING! Hot Steam.
= Please read the instructions booklet.
= Warning! Hot surface.
= Instructions for Use.
= Do not dispose of this product as a normal urban
refuse. Dispose of it at an appropriate differen-
tiated refuse collection point, as required by law
in force.
TROUBLE SHOOTING
Problem
Possible Cause
Solution
The steriliser does not switch ON.
There is no power.
Check that there is power in the mains.
The cable plug or cable connector has not
been plugged in correctly, or they are da-
maged.
Check that the plug and connector have
been plugged in correctly, and that they are
in good condition.
Should the product still not work, contact a
qualified technician.
The feeding bottles are stained at the end of
the sterilisation cycle.
In the appliance there are scale deposits.
Carry out a descaling cycle as indicated in
point IV.
NOTE: There may still be a tendency to
the formation of stains, depending on the
level of calcium contained in the drinking
water used for operating the steriliser.
Noise – Incomplete cycle.
Excessive scale deposits on the heating
plate.
Carry out a descaling cycle as indicated in
point IV.
The display shows the jug symbol.
The display shows the jug symbol.
I n -
complete cycle or the cycle does not start
due to: lack of water or insufficient water to
carry out the cycle, excessive scale residues
on the heating plate.
The water valve on the stopper of the tank
is blocked.
Switch off the appliance and
fill the tank with water or, if necessary, de-
scale the plate.
Check that the stopper does not have ex-
cessive scale residues. In this case, descale
the stopper.
Содержание SterilNaturalDigit
Страница 2: ...2 ...
Страница 23: ...23 a b c e f g d c1 d1 e1 e2 d2 c2 b1 b2 b3 ...
Страница 24: ...24 1 3 5 6 7 4A 4B 2 ...
Страница 25: ...25 7 8 10 12 9 11 13 ...
Страница 94: ...94 AR ...
Страница 95: ...95 ...
Страница 96: ...96 IV تنبيه اجلاري املاء حتت اجلهاز تضع ال املاء في اجلهاز تغمر ال ...
Страница 97: ...97 IV IV ...
Страница 98: ...98 CN ...
Страница 99: ...99 请勿将产品浸入水中 请勿将产品置于流水下 ...
Страница 104: ...Artsana S p A Via Saldarini Catelli 1 22070 Grandate CO Italy www chicco com Rev 01 1407 Cod 46 067288 100 000 ...