Every 100 hours of
operation (or monthly)
Shock absorbers
Check the condition of the shock absorbers located
on either side of the vibrator at regular intervals.
Every 25 hours (3 months)
Clean the air filter.
Every 100 hours (yearly)
♦
Clean and adjust the spark plug.
♦
Check the fuel filter.
♦
Clean the fuel tank.
Every 300 hours (second year)
Replace the spark plug.
Storage
♦
Clean the machine properly before storage, in
order to avoid hazardous substances. See section
“Dust and fume hazard”.
♦
Always store the machine in a dry place.
Disposal
A used machine must be treated and disposed in
such way that the greatest possible portion of the
material can be recycled and any negative influence
on the environment is kept as low as possible, and
in accordance with local restrictions.
Always send used filters and drained oil remnants
to environmentally correct disposal.
The electronic and electrical devices may contain
potentially hazardous substances. Do not dispose
of them in the nature. Dispose them according to
local laws and regulations for the country of use.
According to the European directives 2002/95/EC
and 2002/96/EC.