32
10.3
Manual lubrication without or upon failure of CP−Lube
M
anual lubrication is necessary if the automatic lu
brication fails. For manual lubrication, stand the hy
draulic breaker upright on the working tool and apply
contact pressure.
L
ubricating inter
v
als
:
appro
x
imately e
v
ery 2
5 hours.
5 to
1
0 shots from a grease gun are sufficient.
For preference, only genuine chisel paste should be
used for lubrication.
G
enuine chisel paste is a
v
ailable in fully self
−
empty
ing standard cartridges. Fully emptied cartridges can
be recycled.
CP−Lube
rear side
CP 750
rear side
CP−Lube
CP 1150
CP−Lube
rear side
CP 1650
C
L
CP−Lube
rear side
CP 2250
CP 3050
CP 4250
10.3.1 Filling device for the chisel paste
The Chicago Pneumatics offers a filling de
v
ice to re
fill emptied cartridges, which is fitted on a 45 kg
grease container and allows empty cartridges to be
refilled as re
q
uired.
500 g cartidges for CP
−L
ube
in a carton of 30 pieces,
part ident. no. 33
6
3 0
9
4
9
1
0
M
anual grease gun for cardridges
:
part ident. no. 33
6
3 0345
6
7
1
5 kg grease container
:
part ident. no. 33
6
2 2
6
3
9
00
45 kg grease container
:
part ident. no. 33
6
2 2
6
32 75
For further information on this subject please contact
the Chicago Pneumatic Customer Center
/
dealer in
your region.