Chiappa Arredamenti 120765 SLB RD Скачать руководство пользователя страница 1

BARIATRIC BED 120765 SLB RD

CHIAPPA ARREDAMENTI S.r.l.

Via Monte Rosa 15,

20014 Nerviano (MI) ITALY

www.chiappaarredamenti.com

Instructions for Use

BARIATRIC BED 120765 SLB RD

IFU-120765-SLB-RD-Chiappa-Arredamenti-11/2017#ed04

1

Содержание 120765 SLB RD

Страница 1: ...D 120765 SLB RD CHIAPPA ARREDAMENTI S r l Via Monte Rosa 15 20014 Nerviano MI ITALY www chiappaarredamenti com Instructions for Use BARIATRIC BED 120765 SLB RD IFU 120765 SLB RD Chiappa Arredamenti 11...

Страница 2: ...CHIAPPA ARREDAMENTI 2017 As our policy is one of continuous improvement we reserve the right to modify designs without prior notice The content of this publication may not be copied either wholly or...

Страница 3: ...ult in death injury or other serious adverse reactions Caution Indicates possible hazards in procedures or conditions which if not correctly followed could result in equipment damage or failure Explai...

Страница 4: ...d Fixed Width Foot board 13 Side Rails 13 Electric connection 14 Cable storage 15 Potential equalisation terminal 15 Mattress 17 4 Operation 19 Brakes and steering 19 Side Rails 20 Extendable Head boa...

Страница 5: ...ng the mattress platform 37 Under bed light 38 Patient Handset 38 Attendant Control Panel ACP 40 Function lockout 41 Backup battery 42 Duty cycle lockout 43 5 Product Care 44 Decontamination 44 Preven...

Страница 6: ...General Warnings Continued on next page IFU 120765 SLB RD Chiappa Arredamenti 11 2017 ed04 6...

Страница 7: ...IFU 120765 SLB RD Chiappa Arredamenti 11 2017 ed04 7...

Страница 8: ...ent panels Adjustable length mattress platform Electric CPR function Lithium battery backup Bedstripper linen shelf Underbed light Full width brake bar at foot side steering swivelling braked Patient...

Страница 9: ...SLB RD and serial number of the bed X X X X X X can be found on the specification label located on the bed trolley frame lef side Refer to the SN serial number to identify the bed for assistance purpo...

Страница 10: ...ble Backrest section P Electric set control box battery F Expandable Seat section Q Expandable sections operating knob G Expandable Thigh section R Extendable head board operating knob H Expandable Ca...

Страница 11: ...3 Long term care in a medical area where medical supervision is required and monitoring is provided if necessary e g nursing homes and geriatric facilities Indications The bed is appropriate for high...

Страница 12: ...weight Mattress Accessories including attached loads TOTAL 450kg 12kg 38kg 500kg The recommended patient height is between 146cm and 190cm At the discretion of the carer patients taller than 190cm ma...

Страница 13: ...external rail mounts into the bed frame nylon mounting points pull the upper operating knob and slide the central chrome plated rail mount too until the operating knob makes an audible click To remov...

Страница 14: ...accessible so it can be disconnected quickly in an emergency When the bed is connected to the electricity supply a GREEN indicator will light on the control box The electric set is located underneath...

Страница 15: ...n the black socket at head side To isolate the bed from the electricity supply disconnect the mains plug from the socket outlet Potential equalisation terminal A potential equalisation terminal is loc...

Страница 16: ...Recommended positioning from rear wall at least 8cm from the corner roller buffer IFU 120765 SLB RD Chiappa Arredamenti 11 2017 ed04 16...

Страница 17: ...ndicates the correct mattress size The numbers 1 2 on the label indicate different mattress platform widths and 1 2 3 different mattress platform lengths refer to Bed length adjustment in Chapter 4 IF...

Страница 18: ...t mattresses will typically envelop the patient when loaded and can generally be deeper than a foam mattress without compromising safety Other makes of specialist mattress replacement must be assessed...

Страница 19: ...raight line FREE all four castors are free to rotate and swivel BRAKE brakes are applied on all four castors Using the steering castor Position the bed so that all the castors line up in the direction...

Страница 20: ...drop split side rails adjustable height and detachable They can be adjusted on three different height levels First level all down mattress level Second level mid Third level all up IFU 120765 SLB RD C...

Страница 21: ...e To lower the side rail Hold the top side rail handle third level and pull the UPPER blue operating knob push down the side rail which will slide at the second level mid of height IFU 120765 SLB RD C...

Страница 22: ...then pull the LOWER blue operating knob and push down the side rail at the first level all down mattress level IFU 120765 SLB RD Chiappa Arredamenti 11 2017 ed04 22...

Страница 23: ...so that the side rail folds down below the mattress platform To raise the side rail Grab the top side rail handle and pull it up IFU 120765 SLB RD Chiappa Arredamenti 11 2017 ed04 23...

Страница 24: ...l with an audible click When the side rail is raised at its maximum top height third level then you can adjust it at the second level of height see how to lower the side rail at page 20 or leave it at...

Страница 25: ...EXTENSION Head board is extendable This is needed whenever the mattress platform sections are extended The gap between the head board and the safety side rail must be less than 6 cm EN60601 2 52 The h...

Страница 26: ...h them inside until the lower tube locks with an audible click To remove the head foot board grab the upper frame and lif the board up To put them back in place grab the upper frame and place the two...

Страница 27: ...fied by this symbol Keep hands and fingers away from these areas Extendable mattress platform sections The bariatric bed is supplied with extendable mattress platform sections from 90cm to 105cm and t...

Страница 28: ...he corresponding RED operating knob underneath that section and pull out the section with your hand pull out the extension frame release the RED operating knob until it locks with an audible click The...

Страница 29: ...the backrest and all other platform sections plus levelling and lowering the bed This enables cardio pulmonary resuscitation to be carried out From its top height with maximum profile and tilt electr...

Страница 30: ...plastic laminate panel to release it it will slide for 1 cm and then remove it Egress handle This accessory can be used in place of the standard side rail to make the egress of the patient from the be...

Страница 31: ...ngth adjustment The length of the bed is adjustable to an extended position 20 cm to accommodate very tall patients Operation Locate the lef and right black knobs showed below in the red circle at foo...

Страница 32: ...il the pin of the knob is locked the foot extension now is securely fastened Pull out the mattress retainer panel at foot end item T at page 10 turn it over and position it flat with the metal insert...

Страница 33: ...tate them of 90 and release them now the foot extension is free push it back to its original closed position rotate the knobs back until the pin of the knob is locked see page 31 now the foot extensio...

Страница 34: ...Lifting pole is supplied with two IV hooks on top IV hooks on top safe working load is 5kg each Lifting pole socket Operation Lifing pole socket is located at head end behind the extendable head board...

Страница 35: ...letely inside the socket The two black nylon sockets placed at head end behind the head board can be used for I V pole fixed height and or for oxygen bottle holder Oxygen bottle holder Oxygen bottle h...

Страница 36: ...is completely inside the socket DIN accessory rails The bed may also be fitted with DIN accessory rails right and lef on the second section of the bed Safe working load is 5kg Urine bag holder Urine...

Страница 37: ...panel with locks ACP for use by the carer The functions on both handsets are described separately over the next few pages To adjust the mattress platform press and hold the appropriate button until t...

Страница 38: ...ely 50 above the horizontal 62 if supplied with electrically operated retracting backrest MATTRESS PLATFORM HEIGHT these buttons raise and lower the mattress platform Highest position 39cm 43cm if sup...

Страница 39: ...e mattress platform to a flat position UNDER BED LIGHT this button switches ON the under bed light located at lef side under the trolley frame To switch the light OFF just push the button again The pa...

Страница 40: ...H SECTION These buttons raise and lower the thigh section lower button to raise upper button to lower When the thigh section is raised from the flat position 32 the calf section will be in the Fowler...

Страница 41: ...rged FUNCTION LOCKOUT LOCKOUT INDICATOR LIGHT Function lockout can be used to prevent operation of the controls e g when inadvertent movement of the mattress platform could injure the patient The indi...

Страница 42: ...make a warning when a button on the ACP or Patient Handset is pressed and the battery capacity is low Recharging the backup battery Charging time Approx 10 hours To recharge the battery connect the be...

Страница 43: ...Duty Cycle Lockout IFU 120765 SLB RD Chiappa Arredamenti 11 2017 ed04 43...

Страница 44: ...suitable protective clothing clean all surfaces with a disposable cloth moistened in hand hot water and a neutral detergent Start by cleaning the upper sections of the bed and work along all horizonta...

Страница 45: ...rly neutral pH Many other disinfectants are used in healthcare facilities and it is not possible for CHIAPPA ARREDAMENTI S r l to test each one to determine whether it may affect the appearance or per...

Страница 46: ...r linen shelf remains in its closed position when maximum foot down tilt is applied Check that the bed operates correctly using the backup battery as described in the next section Battery test Check o...

Страница 47: ...lt Trendelenburg 6 Return the mattress platform to the level position 7 Apply maximum foot down tilt reverse Trendelenburg If this test is not completed successfully connect the bed to the electricity...

Страница 48: ...box is not working afer it worked for more than 2 minutes continuously Duty cycle of electrical system exceeded Refer to section Duty cycle lockout in Chapter 4 ACP and Patient Handset are flashing An...

Страница 49: ...00376 Urine bag holder 500960 Electrically operated retracting backrest AVAILABLE ONLY WHEN ORDERED WITH THE BED 500937 Built in scale AVAILABLE ONLY WHEN ORDERED WITH THE BED 500650 Egress handle 500...

Страница 50: ...DEVICES CLASS I and further modifications 2007 47 EC Electric shock protection Class I EMC Complies with EN 60601 1 2 2002 and 2007 Potential equalisation terminal Complies with EN 60601 1 2001 and 2...

Страница 51: ...on 2 Medium 105cm Position 3 Extended 120cm Height of mattress platform centre of seat section to floor STANDARD 39cm to 75cm with INTEGRATED SCALE 43cm to 79cm Head down tilt angle 12 Foot down tilt...

Страница 52: ...mation on correct disposal Transportation and storage Handle with care Do not drop Avoid shock or violent impact This equipment should be stored in a clean dry and well ventilated area which meets the...

Страница 53: ...nufacture Complies with the European Medical Device Directive 93 42 EEC Waste Electrical and Electronic Equipment WEEE do not dispose of this product in general household or commercial waste Serial nu...

Страница 54: ...consent of CHIAPPA ARREDAMENTI S r l or non original components and or non original accessories have been mounted on the bed CHIAPPA ARREDAMENTI S r l also declines any responsibility for Civil Liabil...

Страница 55: ...uipment consider in working cycle meet the EN 60601 1 2 requirement Flicker measurement The result indicate that the equipment consider in working cycle meet the EN 60601 1 2 requirement Fast transien...

Страница 56: ...er frequency magnetic field The result indicate that the equipment consider in working cycle meets the EN 60601 1 2 requirements Dips and voltage interruption immunity test The result indicate that th...

Страница 57: ...and CHIAPPA ARREDAMENTI continuity of future Presence and Service CHIAPPA ARREDAMENTI S r l Via Monte Rosa 15 20014 Nerviano MI ITALY T 0039 0331 587504 E web chiappaarredamenti com W www chiappaarre...