![Chetco Digital Instruments SeaGauge Remote G2 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/chetco-digital-instruments/seagauge-remote-g2/seagauge-remote-g2_user-manual_2596724023.webp)
SeaGauge-Remote G2
User’s Manual
version 031119
Brookings, OR 97415
23
www.chetcodigital.com
Connectors
The SeaGauge-Remote unit has four Deutsch terminal blocks for attachment of power,
pulse, sensor and indicator inputs. Each 12 pin plug is keyed with locking tabs for reliable
connection. The individual crimp style pins accept up to 18 gauge wire and can be inserted
without tools.
The two rear connectors provide for NMEA 2000/J1939 CAN Bus and USB/Serial ports.
NMEA 2000/J1939 use the 5-pin M12 connector. Indicator LED show CAN Bus activity
for transmit and receive and both flash about 1 per second.
Direct attachment to PC USB ports requires a pair of custom USB cables (provided) which
mate with the 8 pin connector. The White USB cable is used for normal calibration
programming with vDash and the Black USB cable is used only for special firmware updates
of the CAN Bus interface