background image

AXXYS

®

 Stairparts 

Fitting Instructions

Newel Posts & Newel Base Connector

Important;

Before you start, slide the AXXYS

®

 newel post into the AXXYS

®

 

newel base connector to make sure it fits snug.  

If the newel is too tight, the spigot on the bottom of the newel 
must be eased so it slides into the base connector, this is 
done by using sandpaper to reduce the taper on the spigot.  
Please DO NOT try to force the newel post into the base 
connector.  
All drilling operations should be accurate, straight and level.

The Newel Base Connector can now be fitted to the 

AXXYS

®

 

newel, slide the connector onto the bottom spigot up to the 

stop, then pre drill and secure using fixings provided (fig. 9). 

Before inserting the bottom newel post, mark and cut the 
newel to a length of 565mm measured from the top of the 
spigot.  
Once cut to length insert the newel post making sure the collar 

meets with the newel base, secure using a PU glue (fig. 9).

Repeat this step for the top newel assembly, but the newel must 
be cut to 750mm to the top of the spigot.

Repeat this step for the Intermediate newel assembly (if you 
require one) the newel must be cut to 590mm to the top of the 
spigot.

Handrail Length & End Brackets

Please Note;

The bottom newel connector is a three part assembly, 
consisting of a newel connector, a handrail connector and a 

handrail cap, with various fixing screws, bolts and washers. 
It must be fitted with the angles in the same orientation as 

the rake of the stairs.

The following is a job best done by two people. 
First you must fit the newel connector onto the top of the 

bottom newel and secure by pre drilling and using the 
two 30mm screws provided, remembering to align the 

connector with the handrail (fig. 10)

29

1/2

Top 750mm

22

1

/

4

Bottom: 

565mm

23

1/4

Intermediate

590mm

Содержание B&Q AXXYS Series

Страница 1: ...ish Freephone 0800 085 3464 AXXYS Stairparts Fitting Instructions Fitting Instructions for AXXYS Stairparts These Fitting Instructions are for use with the AXXYS range with metal balusters within B Q...

Страница 2: ...spindles have also been tested in accordance with BS610 AXXYS is a contemporary range of stair balustrade designed to inspire As a modular system AXXYS provides the flexibility to blend components fr...

Страница 3: ...lie the baserail on top of the tread nosings and push it up against the newel bases mark against the vertical lines of the newel posts and cut achieving a good finish See fig 1 Rest the cut baserail...

Страница 4: ...e making sure to intersect the baserail line Now measure up 175mm from the intersecting point and mark a horizontal line fig 6 Then finally measure the remaining distance to the top of the newel and r...

Страница 5: ...te Newel Base If your staircase is longer than 3 9m measured between inside newel faces then you will require an intermediate newel for added strength This will require an additional newel base to be...

Страница 6: ...top of the spigot Once cut to length insert the newel post making sure the collar meets with the newel base secure using a PU glue fig 9 Repeat this step for the top newel assembly but the newel must...

Страница 7: ...ottom connector Next slide the Bottom connector onto up the handrail line up both the intermediate and the bottom connector into their relevant newels post brackets and drop into place ensure the bolt...

Страница 8: ...the baluster brackets should be pre drilled The bottom baluster should be fixed vertically no more than 99mm from the narrowest part of the newel post in the same way as the top baluster was previous...

Страница 9: ...provided making sure you have lined it up with your landing baserail It is now ready for you to insert the handrail and secure using the two 30mm screws provided fig 16 The handrail can terminate to...

Страница 10: ...You can also rotate it any angle between 90o to 180o to suit a multitude of configurations Now measure the handrail lengths you require from newel to newel including connector and cut to suit Slide b...

Страница 11: ...e your balusters exactly the same way as for the rake The landing balusters should be fixed vertically no more than 99mm from the narrowest part of the newel posts or wall in the same way as the rake...

Отзывы: