3
HOW TO USE THE G689
Select the pulling head for the correct shank diameter and head style of CherryLOCK® rivet and attach it securely to
the G689. For proper installation of the pulling head, see the pulling head tool sheet. Connect the air line to the tool.
Insert the rivet into the application. Place the pulling head over the rivet stem, pushing the tool until the pulling head is
in contact with the rivet head. This will ensure full engagement between the jaws and the rivet stem. When pushing
down on the rivet stem, make certain the tool is perpendicular to the application.
After activating the trigger, the tool will cycle, installing the rivet. After the stem breaks, point the tool toward an
appropriate receptacle and release the trigger. The stem will eject from the front of the tool with a moderate force.
MAINTENANCE AND REPAIR
The G689 has been manufactured to give maximum service with minimum care. In order that this may be accom-
plished, the following recommendations should be followed:
1.
The hydraulic system should be full of oil and free from air at all times.
2.
Keep excessive moisture and dirt out of air supply to prevent wear of air valve, air cylinder and air piston.
3.
Tool should be routinely inspected for oil leaks. Oil leaking around screws (39) indicates that a screw is loose
or a Stat-O-Seal (38) needs replacing. Oil leaking around the small by-pass hole near the base of the handle
grip (61) indicates worn or damaged O-Rings (64).
Use automatic transmission fluid Type “A” (no substitutes). CHERRY® Aerospace recommends using ATF, Dexron III.
DEXRON III OIL SAFETY DATA
FIRST AID
Skin:
Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention. If
irritation develops, consult a physician.
Ingestion:
Seek medical attention immediately. DO NOT INDUCE VOMITING.
Eyes:
Flush with copious amounts of water. If irritation develops, consult a physician.
Inhalation:
No significant adverse health effects are expected to occur on short term exposure. Remove from contaminated area.
Apply artificial respiration if needed. If unconscious, consult physician.
FIRE
Suitable extinguishing media:
CO
2
, dry powder, foam or water fog. DO NOT use water jets.
ENVIRONMENT
Waste Disposal:
In accordance with local, state and federal regulations.
Spillage:
Prevent entry into drains, sewers and water courses. Soak up with diatomaceous earth or other inert material. Store in
appropriate container for disposal.
HANDLING
Eye protection required. Protective gloves recommended. Chemically resistant boots and apron recommended. Use in well ventilated area.
COMBUSTIBILITY
It is slightly combustible when heated above flash point.
It will release flammable vapor which can burn in open or be explosive in confined spaces if exposed to source of ignition.
STORAGE
Avoid storage near open flame or other sources of ignition.
PROPERTIES
Specific gravity
0.863
Weight per gallon
7.18 lbs.
Open flash point
>200°C (392°F)