background image

 

HOW TO USE THE G689 

Select the pulling head for the correct shank diameter and head style of CherryLOCK® rivet and attach it securely to 
the G689. For proper installation of the pulling head, see the pulling head tool sheet. Connect the air line to the tool. 

Insert the rivet into the application. Place the pulling head over the rivet stem, pushing the tool until the pulling head is 
in contact with the rivet head. This will ensure full engagement between the jaws and the rivet stem. When pushing 
down on the rivet stem, make certain the tool is perpendicular to the application. 

After activating the trigger, the tool will cycle, installing the rivet. After the stem breaks, point the tool toward an 
appropriate receptacle and release the trigger. The stem will eject from the front of the tool with a moderate force. 

MAINTENANCE AND REPAIR 

The G689 has been manufactured to give maximum service with minimum care. In order that this may be accom-
plished, the following recommendations should be followed: 

1. 

The hydraulic system should be full of oil and free from air at all times. 

2. 

Keep excessive moisture and dirt out of air supply to prevent wear of air valve, air cylinder and air piston. 

3. 

Tool should be routinely inspected for oil leaks. Oil leaking around screws (39) indicates that a screw is loose 
or a Stat-O-Seal (38) needs replacing. Oil leaking around the small by-pass hole near the base of the handle 
grip (61) indicates worn or damaged O-Rings (64). 

Use automatic transmission fluid Type “A” (no substitutes). CHERRY® Aerospace recommends using ATF, Dexron III. 

 

DEXRON III OIL SAFETY DATA 

FIRST AID 

Skin: 

Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention. If 

irritation develops, consult a physician. 

Ingestion: 

Seek medical attention immediately. DO NOT INDUCE VOMITING. 

Eyes: 

Flush with copious amounts of water. If irritation develops, consult a physician. 

Inhalation: 

No significant adverse health effects are expected to occur on short term exposure. Remove from contaminated area. 

Apply artificial respiration if needed. If unconscious, consult physician. 

FIRE 

Suitable extinguishing media: 

CO

2

, dry powder, foam or water fog. DO NOT use water jets. 

ENVIRONMENT 

Waste Disposal: 

In accordance with local, state and federal regulations. 

Spillage: 

Prevent entry into drains, sewers and water courses. Soak up with diatomaceous earth or other inert material. Store in 

appropriate container for disposal. 

HANDLING 

Eye protection required. Protective gloves recommended. Chemically resistant boots and apron recommended. Use in well ventilated area. 

COMBUSTIBILITY 

It is slightly combustible when heated above flash point.  
It will release flammable vapor which can burn in open or be explosive in confined spaces if exposed to source of ignition. 

STORAGE 

Avoid storage near open flame or other sources of ignition. 

PROPERTIES 

Specific gravity 

0.863 

Weight per gallon 

7.18 lbs. 

Open flash point 

>200°C (392°F) 

Содержание G-689

Страница 1: ...ORIGINAL INSTRUCTIONS G 689 Hydro Shift CherryLOCK Riveter 1224 E Warner Ave Santa Ana CA 92705 www cherryaerospace com...

Страница 2: ...le Shooting 4 Overhaul 5 Air Valve Sub Assembly 5 Head Sub Assembly 5 6 Handle Sub Assembly 7 Adjustment Instructions 8 Shift Point Setting 8 9 Shift Piston Check 9 G689 Pulling Heads 10 Tool Capacity...

Страница 3: ...e operated in any posi tion with one hand The H681 Series pulling heads fit directly on this tool to install both bulbed and standard NAS type 2000 Series CherryLOCK Rivets With the proper adapters an...

Страница 4: ...es are always in good condition Excessive contact with the hydraulic oil should be avoided to minimize the possibility of rashes Care should be taken to wash thoroughly Operating air pressure should n...

Страница 5: ...ll by pass hole near the base of the handle grip 61 indicates worn or damaged O Rings 64 Use automatic transmission fluid Type A no substitutes CHERRY Aerospace recommends using ATF Dexron III DEXRON...

Страница 6: ...need replacing If oil should leak through the by pass hole at the base of the handle 61 the O rings 64 are worn or damaged Oil leaking from the front of the head 13 indicates that O rings 5 and 11 ar...

Страница 7: ...sleeve 72 unless the ports in the sleeve have become plugged from contaminated air The O rings on this sleeve are static and therefore do not wear If it is suspected that the ports are plugged use nee...

Страница 8: ...bly into the large hole of clamp wrench 680A48 49 locating on a polished surface Tighten the wrench s cap screws securely so that the shift piston sub assembly cannot turn in the clamp Place the clamp...

Страница 9: ...to the handle see Fill and Bleed Instructions Also make sure to place O rings 40 on top of adapter 86 O ring 87 and gasket 88 on the top of the handle and that they are properly oriented Tighten the f...

Страница 10: ...ylinder tool 530A88 push air piston 49 with quad ring 48 and back up rings 47 into air cylinder until it engages threaded end of power piston and rod sub assembly 92 Using piston rod wrench 530A86 tig...

Страница 11: ...ockwise Gage point C should now be flush with the front of tool head as shown in sketch CAUTION Always release the tool trigger before turning knob and never back off more than 12 turns or the shift s...

Страница 12: ...C 4 ALL ALL ALL ALL ALL ALL H681 5C 5 ALL ALL ALL ALL ALL ALL H681 6C 6 ALL ALL ALL ALL ALL ALL OTHER PULLING HEADS THAT WILL FIT THIS TOOL ARE SHOWN ON THE CHART BELOW PULLING HEAD TYPE ADAPTER RIVET...

Страница 13: ...11 CROSS SECTION DRAWING G689...

Страница 14: ...2 43 P 213 RING BACK UP 676 500 088 4 44 P 215 RING QUAD 693 487 103 2 45 P 196 O RING 1 574 1 296 139 1 46 530B14 PLUG PACKING 1 PART LIST FOR THE G689 689D1 HYDRO SHIFT RIVETER ITEM NO PART NUMBER...

Страница 15: ...13 EXPLODED VIEW OF G689...

Страница 16: ...tive or nonconforming goods or installation of replacement goods shall be Buyer s responsibility SELLER S WARRANTY DOES NOT APPLY WHEN ANY PHYSICAL OR CHEMICAL CHANGE IN THE FORM OF THE PRODUCT IS MAD...