GS8536-EX
GYB18.1155
IECEx
CQM14
.
0048
CZ.GS8536-EX.11(S)E-5.1/18.01
5
4
1
2
3
M3
8.0
XK06-014-00557
(1)
(2).
(3).
(4).
.
This
barrier
adopts
knock
-
down
connector
with
screw
terminals
.
The
intrinsically
safe
(
IS
for
short
)
terminals
(
blue
plugs
)
should
be
connected
to
hazardous
area
devices
and
the
non
-
IS
ones
(
green
plugs
)
to
the
safe
area
devices
.
Choose
for
the
harzardous
area
the
blue
-
marked
wires.
Its
minimum
2
cross
section
area
should
be
0
.
5
mm
,
and
minimum
d
i
electric
strength
should
be
500V
.
The
wirings
in
safe
area
and
hazardous
area
must
be
separated
,
and
both
have
protection
bushes.
A
length
of
8mm
bared
wire
is
locked
by
the
M3
bolt
.
See
as
shown
below
.
(
1
).
Insert
a
screwdriver
(
its
edge
length
≤
6mm
)
into
the
downside
metal
lock
of
the
barrier;
(
2
).
Push
the
screwdriver
upwards
,
then
prize
the
metal
lock
downwards;
(
3
).
Take
the
barrier
out
of
the
guide
rail
.
(
1
).
Before
using
,
please
check
again
whether
the
module’s Ex-proof
rating accords to the operation conditions, and
also
wiring
and
polarity
are
correct
.
(
2
).
It
is
disallowable
to
test
insulativity
among
the
terminals
with
a
megameter
.
If
necessary
,
the
wires
must
be
cut
off
before
testing
,
or
the
internal
fuse
would
blow
.
(
3
).
Every
product
has
been
test
strictly
before
leaving
factory
.
If
users
find
any
abnormality
in
the
module
,
please
contact
the
nearest
agent
or
our
company
.
(
4
).
In
5
yeras
from
the
delivery
date
,
if
the
product
works
improperly
during
normal
operation
,
we
will
repair
or
replace
it
without
payment
.
Non
-
intrinsically safe terminals
Intrinsically safe terminals
Add: Building 6, 201 Minyi Road, Caohejing Hi-Tech Park
Songjiang New Industrial Park, Shanghai 201612, P.R. China
Tel : +86-21-64513350 Fax : +86-21-64846984
Email
:
chenzhu
@
chenzhu
-
inst
.
com
http://www.chenzhu-inst.com
Caution
Please check whether the product type on the package accords
to the ordering contract;
Read this manual carefully before installation or using. If there is
something unclear, please dial technic support hotline-400 881 0780;
Isolated barrier should be located in the safe area;
Supply voltage is 24VDC, 220VAC is forbidden;
Users are not allowed to dismantle or repair the barrier otherwise
it will induce malfunction.
Please read the instruction manual carefully before use the product,
and please safekeeping.
YEAR
YEAR
WARRANTY
WARRANTY
3
2
1
The
isolated
barrier
should
be
located
at
safe
area
,
according
to
the
related
requirements
in
IEC60079
-
14
(
EN60079
-
14
)
,IEC60079
-
17
(
EN60079
-
17
)
,IEC60079
-
19
(
EN60079
-
19
)
,IEC60079
-
25
(
EN60079
-
25
),
GB15577
,
GB12476 and GB50257.
GS8500
-
EX
series
isolated
barrier
are
designed
for
mounting
on
35mm
DIN
guide
rail
.
Installation
according
to
the
following
steps
:
(
1
).
First
make
the
bus
-
powered
outlet
locked
into
the
guide
rail;
(
If
no
bus
-
powered
function
,
omit
this
step
)
;
(
2
).
Make
the
upside
of
the
barrier
locked
into
the
guide
rail;
(
3
).
Push
the
downside
of
the
barrier
in
the
rail
.