Relay Output Cards 

 

 

Features 

 

The  Mxp-007  and  Mxp-008  are  internal  peripherals  for  use  with  the  MxPro  4  panels.    The  units  connect 
directly to the panel’s motherboard and provide either 2 or 8 individually programmable 1-Amp rated, volt free, 
clean contact outputs. 

Each output can be individually assigned to an output group  to provide full support for the MxPro 4 

system’s 

DynamiX  zoning  facilities.    In  addition,  each  output  has  a  number  of  programmable  operational  parameters 
including fail-safe, can-silence, allow walk test and delayed operation.   

These features not only aid commissioning and cut down on expensive ancillary hardware but also allow the 
system  to  be  easily  configured  to  provide  full  support  for  the  more  complex  cause  and  effect  configurations 
using standard products. 

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Mxp-007

Page 1: ...ndividually assigned to an output group to provide full support for the MxPro 4 system s DynamiX zoning facilities In addition each output has a number of programmable operational parameters including...

Page 2: ...r Mx 4400 control panel Up to two 2 Way or 8 Way Relay Output Cards can be fitted to an Mx 4800 control panel Compatibility The Mxp 007 is fully compatible with the Mx 4100 Mx 4200 Mx 4400 and Mx 4800...

Page 3: ...4 1 2 INSTALLING THE MXP 007 IN THE MX 4200 MX 4400 MX 4800 4 1 2 1 Mounting the Card 4 1 2 2 Internal Wiring 4 1 3 INSTALLING THE MXP 008 IN THE MX 4200 MX 4400 MX 4800 5 1 3 1 Mounting the Card 5 1...

Page 4: ...hed header PL2 to the 4 way latched header on the base card 1 2 Installing the Mxp 007 in the Mx 4200 Mx 4400 Mx 4800 1 2 1 Mounting the Card Base Card M3 Fixing Screws Mxp 007 The card mounts on 4 pi...

Page 5: ...uts are required on the Mx 4200 or Mx 4400 then use the deeper back box Mxm 020 or use the Termination Enclosures Mxm 028 or Mxm 029 as appropriate RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5 RELAY 6 RELA...

Page 6: ...Mxp 008 By default the relays are all in the same Output Group 199 but this can be changed as required In the example below the relays have been assigned to groups 180 to 187 These output groups can b...

Page 7: ...ill be normally energised in its quiescent state and de energised when its Output Group setting is activated 2 3 May Walk Test If this parameter is ticked the relays assigned with this parameter will...

Page 8: ...www advancedco com 8 This page is intentionally left blank...

Page 9: ...www advancedco com USER NOTES...

Page 10: ...dco com Advanced Electronics Ltd Moorland Way Cramlington Northumberland NE23 1WE UK Tel 44 0 1670 707 111 Fax 44 0 1670 707 222 Email sales advancedco com Web www advancedco com Doc Number 680 028 Re...

Reviews: