Press
退针
EJECT BWD
button, and the ejector retraction is back to the end after 4
seconds running of Timer TIM20 with warning signal disappearing. The
actual position of ejector is automatically changed to preset position
with setting value of 0.5mm, and the initial point reset is completed.
In case the ejector retraction is not back to the end, reset ejector initial
point again.
(3) Injection
In the event of injection and plasticizing, the computer power supply is
suddenly cut off. The screen prompts warning signal “Reset initial point,
please press INJECT key until warning signal disappears” while
restarting the computer.
The reset method of injection initial point is as follows:
Press
INJ
射胶
key, and the injection touched the end after 4 seconds running of
Timer TIM20. The actual injection position is automatically changed to
preset position with setting value of 0.5mm, and the warning signal
disappears. Then the initial reset is completed.
In case the ejector retraction is not back to the end after 4 seconds
running of Timer TIM20, reset ejector initial point again.
5.54 Initial position setting of decoder
(1)
In the initial setting interface (61), there are mould clamping presetting, mould
clamping initial point, injection presetting, injection initial point and ejector presetting
and ejector initial point.
(i)
Function of presetting is to alter the current value of decorder position
and manually adjust initial point position.
(ii)
Function of initial point is to reset the position of decorder.
(2)
Preset operation method (method to alter actual position of decoder)(mould
clamping ):
Move the cursor to preset position DD of mould clamping, and input the position
required to set, and preset input key, then move the cursor back to the preset
position of mould clamping, and preset input key, at this time, the screen will
show”?”, then, press confirm key, to complete setting, and the current mould
clamping position is the preset position of mould clamping.
(The operation method of injection presetting is the same as the ejector
prospecting’s).
Содержание Ai-02
Страница 7: ...Ai 02 Operation Manual 4 Introduction on each Part of Computer s Panel 4 1 Computer s Panel 7...
Страница 48: ...5 24 Time monitor Time monitor interface 27 Time monitor interface 28 Time monitor interface 29...
Страница 49: ...Time monitor interface 30...
Страница 59: ...5 33 Help Help interface 40 Help interface 41 Help interface 42...
Страница 110: ...6 4 Ai 02 circuit diagram 6 4 1 Ai 02 Input Connection Encoder Version...
Страница 113: ...6 4 4 Ai 02 Motor Power Control Circuit SVP...
Страница 115: ...6 4 6 Ai 02 Input Point Connection Diagram of Computer I O Board...
Страница 116: ...6 4 7 Ai 02 Output Point Connection Diagram of Computer I O Board...
Страница 117: ...6 4 8 Ai 02 extension I O board Connection Diagram...
Страница 119: ......
Страница 120: ......
Страница 121: ......
Страница 122: ......
Страница 123: ......
Страница 124: ......