2
)
By pressing
key, select item to be input, input corresponding
value, and
(
3
)
press
key to complete setting.
Of which,
"AA"
:
Set mould thickness
"BB"
:
Minimum of mould clamping position
"CC"
:
Maximum of mould clamping position
"DD"
:
Preset of mould clamping position
"EE"
:
Preset of ejector position
"FF"
:
Preset of injection position
"GG"
:
Original value of mould clamping
"HH"
:
Original value of ejector
"II"
:
Original value of injection
Setting of origin data for potentiometer
,
move the potentiometer by hand up to
the minimum position
,
copy the
actual position data to the
origin
,
then press
key to complete setting. Again move the potentiometer by
hand up to the maximum position
,
copy
actual position data to
maximum location and then press
key to complete the setting
。
Cyliner length
=(
maximum position
-
minimum origin
)
/10
。
Others data on the screen
:
"A1"
:
mold thickness
,
After clamping end, measure the current thickness of the
mold and input the data
。
"A2"
:
During auto mold adjustment, the correspond position for adjusting half
of maximum clamping force
。
"A3"
:
During auto mold adjustment, the correspond position for adjusting
maximum clamping force
。
Those data are adjusted or preset before shipment
。
It is recommend not to
be adjusted by customer. Please consult service department.
Содержание Ai-02
Страница 7: ...Ai 02 Operation Manual 4 Introduction on each Part of Computer s Panel 4 1 Computer s Panel 7...
Страница 48: ...5 24 Time monitor Time monitor interface 27 Time monitor interface 28 Time monitor interface 29...
Страница 49: ...Time monitor interface 30...
Страница 59: ...5 33 Help Help interface 40 Help interface 41 Help interface 42...
Страница 110: ...6 4 Ai 02 circuit diagram 6 4 1 Ai 02 Input Connection Encoder Version...
Страница 113: ...6 4 4 Ai 02 Motor Power Control Circuit SVP...
Страница 115: ...6 4 6 Ai 02 Input Point Connection Diagram of Computer I O Board...
Страница 116: ...6 4 7 Ai 02 Output Point Connection Diagram of Computer I O Board...
Страница 117: ...6 4 8 Ai 02 extension I O board Connection Diagram...
Страница 119: ......
Страница 120: ......
Страница 121: ......
Страница 122: ......
Страница 123: ......
Страница 124: ......