16000 Appliances Hardware
16000 Appliances Getting Started Guide | 39
Item
Component
Description
4
Grounding
lugs
Used to connect grounding.
5
LED indicator
for each
power supply
unit
n
Off - No power cord is connected to any of the PSUs in the system
n
Green - System on
n
Blinking green - Power cords are connected to all PSUs, but system is
off
n
Amber - No power cord is connected to the PSU, but other PSUs in the
system have a power cord connected
n
Blinking amber - Warning about a hardware issue (high temperature,
high power, high current, slow fan) might lead to an issue with the PSU
n
Blinking fast green - PSU in Firmware update
6
Power supply
units
Dual redundant power supplies that you can hot swap. Each power supply unit
connects to an electric outlet.
You can use the cable restraints to avoid accidental removal of the power
supply cable.
In 16000/16200 appliances - The PSUs are numbered from top to bottom in
the OS as Power Supply #1 and Power Supply #2.
In 16600HS appliances - The PSUs are numbered from left to right in the
OS as Power Supply #1 and Power Supply #2.
Note
- 16000/16200 Base appliances that use AC PSUs, contain one AC PSU
and one dummy filler.
See
"PSU Configuration and Monitoring" on page 43
7
Thumb
screws for
cooling fan
unit
Loosen screws to remove cooling fan unit from the appliance.
8
Cooling fan
units
Numbered from right to left:
1
,
2
,
3
,
4
.
9
Location LED
n
Off - Location beacon is turned off
n
Blinking blue - Location beacon is turned on through the
Gaia Portal
or
Gaia Clish
n
Solid blue - Location beacon is turned on through the
Locator
button
Note - Turn off the Location LED the same way you turned it on.
10
Main power
switch
When the appliance is turned off, turns the appliance on.
When the appliance is turned on, pressing and releasing the switch will start an
orderly shutdown process. Alternatively, holding the switch for 4 seconds will
force a machine shut down.