DMX Channel Values 

Channel 

Value 

Function 

000 

 031 

032 

 063 

064 

 095 

096 

 127 

128 

 159 

160 

 191 

191 

 223 

224 

 255  

Color Wheel

 

Open 
Red 
Blue 
Green 
Yellow 
Orange 
Magenta 
UV (Purple) 

000 

 004 

005 

 249 

250 

 255 

Dimmer

 

No Output 
Closed > Open 
Full Output (100%) 

Gobos 

Maintenance 

To maintain optimum performance and minimize wear fixtures should be cleaned frequently.  Usage 

and environment are contributing factors in determining frequency. As a general rule, fixtures should 

be cleaned at least twice a month. Dust build up reduces light output performance and can cause 

overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off 

fixture before conducting maintenance. 

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust 

collected on external vents and internal components.  Clean all glass when the fixture is cold with a 

mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply 

solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical 

surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil 

and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or 

becomes dirty, clean the lamps with an alcohol wipe.  

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: 

damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on th

e unit’s 

optics. Clean with soft cloth using normal glass cleaning fluid.  Always dry the parts carefully. Clean 

the external optics at least every 20 days. Clean the internal optics at least every 30/60 days. 

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). 

Products returned without an RMA # will be refused. Call CHAUVET® and request RMA # prior to 

shipping the fixture. Be prepared to provide the model number, serial number and a brief description 

of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from 
inadequate packaging is the customer’s responsibility. CHAUVET® reserves the right to use its own 

discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is 

always a safe method to use. 

Содержание TFX-FS360

Страница 1: ... chauvetlighting com 2010 07 20 14 53 TFX FS360 Followspot 400G Ask your dealer about the specially designed tripod stand with casters for the TFX FS360 Model Number CH W28 READ FIRST To start using as a Followspot press the FUNCTION button until the Manual LED turns on USER MANUAL ...

Страница 2: ...PRODUCT OVERVIEW 4 SETUP 5 LAMP 5 Lamp installation 5 POWER 5 GOBO HOLDER 5 MOUNTING 6 Orientation 6 Static Mount 6 Tripod Stand with Casters CH W28 optional 6 OPERATING INSTRUCTIONS 7 OPERATING MODES 7 Followspot Mode 7 DMX Mode 8 Setting the starting address 8 APPENDIX 9 DMX PRIMER 9 Fixture Linking 9 DMX CHANNEL VALUES 10 GOBOS 10 MAINTENANCE 10 RETURNS PROCEDURE 10 CLAIMS 11 GENERAL TROUBLESHO...

Страница 3: ...eep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do no...

Страница 4: ... mechanical iris Variable mechanical focus Additional Features Followspot stand CH W28 Options Single gobo slot with 4 free gobos DMX Channel Summary CHANNEL FUNCTION 1 Color 2 Dimmer Product Overview Gobo holder Located and inserted on the bottom side of the followspot Iris Control panel Lamp access Focus Focus handles Yoke Control panel Gobos included DMX Input Output Optional CH W28 Tripod w ca...

Страница 5: ...ady optimized inside the reflector Power Warning Verify that the power on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Ground To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating is its average curre...

Страница 6: ... both knobs When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables should always be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation TRIPOD STAND WITH CASTERS CH W28 OPTIONAL The CH W28 is a multipurpose followspot speaker stand with casters As...

Страница 7: ... LED is turned on BUTTONS FUNCTION DIMMER Min and Max buttons adjust the intensity of the light output respectively SHUTTER The electronic shutter provides instant lights on or shuts all light output off for a blackout state Color Buttons The following colors can be immediately selected by pressing each individual button UV Magenta Orange Yellow Green Blue red and White FUNCTION Press FUNCTION but...

Страница 8: ...tart address For example a fixture that occupies or uses 6 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addresses so that the channels used do not overlap and notate the start address selected for future reference If this is your first time addressing a fixture using the DMX 512 control protocol than I suggest ...

Страница 9: ...y Chain A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male ...

Страница 10: ... touch the lamp glass when cleaning fixture Oil and dirt can cause damage and premature aging of the lamp In the event that the lamp is touched or becomes dirty clean the lamps with an alcohol wipe The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates ...

Страница 11: ...oad placed on device Chase is too slow Check users manual for speed adjustment Device has no power Check for power on Mains Check device s fuse internal and or external Fixture is not responding Check DMX Dip switch settings for correct addressing Check DMX cables Check polarity switch settings Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life L...

Страница 12: ...75 hr PHOTO OPTIC Luminance 1 m 48 420 lux Beam Angle 2 12 THERMAL Maximum ambient temperature 40 C 104 F CIRCUIT BREAKER Main 120 V 7 A Main 230 V 5 A CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 2 ORDERING INFORMATION Followspot 400G TFX FS360 Tripod St...