background image

 

 

 

 

Page 18 of 18 

SlimPAR™ Tri IRC series User Manual (Rev. 5) 

6.

 

T

ECHNICAL 

S

PECIFICATIONS

 

 

 

Dimensions and 

Weight

 

Length (Tri 12) 

Width (Tri 12) 

Height (Tri 12) 

Weight (Tri 12) 

9.5 in (235 mm) 

4.6 in (115 mm)  

11.5 in (292 mm) 

5.7 lbs (2.6 kg) 

Length (Tri 7) 

Width (Tri 7) 

Height (Tri 7) 

Weight (Tri 7) 

7.7 in (195 mm) 

4.6 in (118 mm) 

8.5 in (215 mm) 

3.8 lbs (1.7 kg) 

 

Note: 

Dimensions in inches rounded to the nearest decimal digit 

Note:

 Unless otherwise indicated, all specifications are applicable to both the SlimPAR™ Tri 7 IRC 

and the SlimPAR™ Tri 12 IRC.

 

 

 

 

 

Power

 

Power Supply Type 

Range 

Voltage Selection 

Switching (internal) 

100~240 V, 50/60 Hz 

Auto-ranging 

 

 

 

SlimPAR™ Tri 12 IRC

 

120 V, 60 Hz 

230 V, 50 Hz 

Consumption 

64 W 

67 W  

Operating 

0.5 A 

0.3 A 

Power linking current (units) 

8 A (15 units) 

8 A (26 units) 

Fuse 

F 1 A, 250 V 

F 1 A, 250 V 

SlimPAR™ Tri 7 IRC

 

120 V, 60 Hz 

230 V, 50 Hz 

Consumption 

42 W 

47 W 

Operating 

0.3 A 

0.2 A 

Power linking current (units) 

8 A (23 units) 

8 A (39 units) 

Fuse 

F 1 A, 250 V 

F 1 A, 250 V 

 

 

 

 

 

Power I/O 

US/Worldwide 

UK/Europe 

Power input connector 

IEC 

IEC 

Power output connector 

Edison 

IEC 

Power Cord plug 

Edison (U.S.) 

Local plug 

 

 

 

 

Light Source

 

Type 

Power 

Lifespan 

LED 

1 W 

50,000 hours 

 

 

 

 

 

Parameter 

SlimPAR™ Tri 12 IRC 

SlimPAR™ Tri 7 IRC 

Color 

Tri-color 

Tri-color 

Quantity 

12 

Current 

350 mA (x 3) 

350 mA (x 3) 

 

 

 

 

Photo Optic

 

Parameter 

SlimPAR™ Tri 12 IRC 

SlimPAR™ Tri 7 IRC 

Illuminance @ 2 m 

2,662 lux 

1,073 lux 

Beam angle 

20º 

20º 

Field angle 

34º 

34º 

 

 

 

 

Thermal

 

Maximum External Temp. 

Cooling System 

 

104° F (40° C) 

Convection 

 

 

 

 

 

DMX

 

I/O Connectors 

Connector Type 

Channel Range 

3-pin XLR 

Sockets 

3, 7 

 

 

 

 

Ordering

 

Product Name 

Item Code 

Item Number 

SlimPAR™ Tri 12 IRC 

03030405 

SLIMPARTRI12IRC 

SlimPAR™ Tri 7 IRC 

03030404 

SLIMPARTRI7IRC 

 

 

 

 

 

 

 

Содержание Slim PAR TRI 12 IRC

Страница 1: ...User Manual ...

Страница 2: ...ensions SlimPAR Tri 7 IRC 8 3 Setup 9 AC Power 9 Fuse Replacement 9 Power Linking 10 Mounting 11 Orientation 11 Rigging 11 4 Operation 12 Control Panel Operation 12 Menu Map 12 Configuration DMX 13 Starting Address 13 Configuration Standalone 13 Automatic Mode 13 Static Color Mode 13 Custom Static Color Mode 13 Master Slave Mode 14 Infrared Control 14 IRC Infrared Remote Control Operation 15 DMX C...

Страница 3: ...nu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the product s control panel ON A value to be entered or selected Symbols Symbol Meaning Critical installation configuration or operation information Not following these instructions may make the product not work cause damage to the product or cause harm to the operator Important instal...

Страница 4: ...ng because it may be very hot Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from a...

Страница 5: ...SlimPAR Tri IRC series User Manual Rev 5 Page 5 of 18 2 INTRODUCTION Product Overview SlimPAR Tri 12 IRC LED Display Power In DMX Out Safety Loop DMX In Bracket Adjustment Knob Fuse Holder Power Out ...

Страница 6: ...Page 6 of 18 SlimPAR Tri IRC series User Manual Rev 5 Product Overview SlimPAR Tri 7 IRC LED Display Power In DMX Out DMX In Bracket Adjustment Knob Fuse Holder Power Out Safety Loop ...

Страница 7: ...SlimPAR Tri IRC series User Manual Rev 5 Page 7 of 18 Product Dimensions SlimPAR Tri 12 IRC ...

Страница 8: ...Page 8 of 18 SlimPAR Tri IRC series User Manual Rev 5 Product Dimensions SlimPAR Tri 7 IRC ...

Страница 9: ...e electrical ground to avoid the risk of electrocution or fire Never connect the product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement Disconnect the product from the power outlet before replacing the fuse 1 Disconnect the product from power 2 Wedge the tip of a flat head screwdriver into the slot of the f...

Страница 10: ... Tri 7 IRC units on 230 VAC You can power link up to 15 SlimPAR Tri 12 IRC units on 120 VAC or up to 26 SlimPAR Tri 12 IRC units on 230 VAC The power linking diagram shown above corresponds to the North American version of the product ONLY If using the product in other markets you must consult with the local CHAUVET distributor as power linking connectors and requirements may differ in your countr...

Страница 11: ...roduct securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss you should use a mounting clamp of appropriate weight capacity When power linking multiple products you must always consider the length of the power linking cable and mount the products close enough for the cable to reach The bracket adjustment knobs allow for directional adjustment whe...

Страница 12: ...oll down the list of options or to find a lower value ENTER Press to activate a menu option or a selected value Menu Map Mode Programming Steps Description 3 CH d001 512 3 channel DMX mode RGB 7 CH d001 512 7 channel DMX mode C C1 Red Static color C2 Green C3 Blue C4 Cyan C5 Magenta C6 Yellow C7 White P P1 7 color program switching P2 7 color program fading P3 3 color program switching P4 3 color ...

Страница 13: ... Connect the product to a suitable power outlet 2 Turn the product on Never connect a product that is operating in any standalone mode either Static or Automatic to a DMX string connected to a DMX controller Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller Automatic Mode To enable the Automatic Mode follow the instructions below 1 P...

Страница 14: ... the previous slave unit 6 Finish setting and connecting all the slave units Master unit 1 Set the master unit to operate in either Automatic or Static Color mode 2 Make the master unit the first unit in the DMX daisy chain Configure all the slave units before connecting the master unit to the DMX daisy chain Never connect a DMX controller to a DMX string configured for Master Slave operation beca...

Страница 15: ...ontrol To choose a specific color with the IRC 1 Press MANUAL on the IRC 2 Press any number between 0 9 to choose your color To manually control the RGB percentage 1 Press MANUAL on the IRC 2 Press R G or B to choose your color 3 Press or to increase or decrease the percentage of each color Miscellaneous Operation To adjust the strobe rate of the program 1 Press STROBE on the IRC 2 Press or to inc...

Страница 16: ...ld up reduces light output performance and can cause overheating This can lead to reduction of the light source s life and mechanical wear To maintain optimum performance and minimize wear clean the product at least twice a month However usage and environmental conditions contribute to increased cleaning frequency To clean the product follow the instructions below Unplug the product from power Wai...

Страница 17: ...T will refuse any product returned without an RMA number Write the RMA number on a properly affixed label DO NOT write the RMA number directly on the box Before sending the product clearly write the following information on a piece of paper and place it inside the box Your name Your address Your phone number The RMA number A brief description of the problem Be sure to pack the product properly Any...

Страница 18: ...A 15 units 8 A 26 units Fuse F 1 A 250 V F 1 A 250 V SlimPAR Tri 7 IRC 120 V 60 Hz 230 V 50 Hz Consumption 42 W 47 W Operating 0 3 A 0 2 A Power linking current units 8 A 23 units 8 A 39 units Fuse F 1 A 250 V F 1 A 250 V Power I O US Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison U S Local plug Light Source Type Power Lifespan LED 1 W 50...

Отзывы: