background image

 

J-Six™ User Manual 

Rev. 4

 

1.

 

B

EFORE 

Y

OU 

B

EGIN

 

What is Included 

Ø

 

1 x J-Six™ 

Ø

 

1 x Power Cord 

Ø

 

1 x Warranty Card 

Ø

 

1 x User Manual 

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

Manual Conventions 

CHAUVET® manuals use the following conventions to differentiate certain types of information from 

the regular text. 

C

ONVENTION

 

M

EANING

 

[10] 

A DIP switch to be configured  

<Menu> 

A key to be pressed on the fixture’s control panel 

1~512 

A range of values 

50/60 

A set of values of which only one can be chosen 

Settings 

A menu option not to be modified (for example, showing the operating mode/current status) 

MENU >

 

Settings

 

A sequence of menu options to be followed 

ON 

A value to be entered or selected 

Icons 

This manual uses the following icons to indicate information that requires special attention on the part 

of the user. 

I

CON

 

M

EANING

 

 

This paragraph contains critical installation, configuration or operation information. Failure 
to comply with this information may render the fixture partially or completely inoperative, 
cause damage to the fixture or cause harm to the user. 

 

This paragraph contains important installation or configuration information. Failure to 
comply with this information may prevent the fixture from functioning correctly. 

 

This paragraph reminds you of useful, although not critical, information. 

 

AC Power 

This fixture has power switch that can accommodate 120 V and 230 V, 50/60 Hz. The only thing 

necessary to do before powering on the unit is to make sure the power switch is set to the appropriate 

line voltage. All fixtures must be powered directly off a switched circuit and cannot be run off a 

rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for 

a 0–100% switch. 

 
 

All fixtures must be connected to circuits with a suitable Earth Ground.  

Содержание J-Six

Страница 1: ...User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave 120 V 230 V Switchable Replaceable Fuse User Serviceable ...

Страница 2: ... AC POWER 3 Power Linking 4 CONTACT US 5 SAFETY INSTRUCTIONS 5 2 INTRODUCTION 6 FEATURES 6 PRODUCT OVERVIEW 6 MOUNTING 7 Orientation 7 Rigging 7 Fuse Replacement 7 3 OPERATING INSTRUCTIONS 7 STANDALONE MODE SOUND ACTIVE 7 4 APPENDIX 8 GENERAL MAINTENANCE 8 RETURNS PROCEDURE 8 CLAIMS 8 GENERAL TROUBLESHOOTING 9 TECHNICAL SPECIFICATIONS 9 ...

Страница 3: ... showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This manual uses the following icons to indicate information that requires special attention on the part of the user ICON MEANING This paragraph contains critical installation configuration or operation information Failure to comply with this information may...

Страница 4: ...re contains power linking via the edison outlet located next to the power input cable Please see the diagram below for further explanation The maximum quantity of fixtures that may be linked is 36 Additional power link out Fixture 1 Fixture 2 Fixture 3 ...

Страница 5: ...lled in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots are blocked Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by ...

Страница 6: ...ds rotate separately together and or against each other Built in sound activated programs Additional power output max 36 units Product Overview Hanging bracket Bracket adjustment knob Microphone sensitivity adjustment knob Voltage selection switch Power Out Microphone Power In Fuseholder ...

Страница 7: ...be exposed to rain high humidity extreme temperature changes or restricted ventilation Fuse Replacement 1 With a flat head screwdriver wedge the fuse holder out of its housing 2 Remove the damaged fuse from its holder and replace with exact same type fuse 3 Insert the fuse holder back in its place and reconnect power 3 OPERATING INSTRUCTIONS Standalone Mode Sound Active This mode allows a single u...

Страница 8: ...fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET ...

Страница 9: ...l and or external ü ü ü No light output Call service technician ü If you still have a problem after trying the above solutions please contact CHAUVET Technical Support Technical Specifications WEIGHT DIMENSIONS Length 11 3 in 287 mm Width 11 1 in 281 mm Height 7 2 in 182 mm Weight 6 9 lbs 3 2 kg POWER Manual Power Switch 100 V 230 VAC 50 60 Hz Power Consumption 120 V 16 W 0 2 A max 0 2 A inrush Po...