General Troubleshooting 

Symptom 

Solution(s) 

Applies to 

Lights 

Foggers 

& Snow 

Controllers 

Dimmers

& Chaser 

Breaker/Fuse keeps 
blowing 

Check total load placed on device 

 

 

 

ü

 

Device has no power 

Check for power on Mains. 
Check device’s fuse. (internal and/or external) 

ü

 

 

ü

 

ü

 

No light output 

Call service technician 

ü

 

 

 

 

 

If you still have a problem after trying the above solutions, please contact CHAUVET® 
Technical Support. 

 
 
Technical Specifications 

WEIGHT & DIMENSIONS 

Length ............................................................................................................................................. 11.3 in (287 mm) 
Width ............................................................................................................................................... 11.1 in (281 mm) 
Height ............................................................................................................................................... 7.2 in (182 mm) 
Weight................................................................................................................................................. 6.9 lbs (3.2 kg) 
 

POWER 

Manual Power Switch..................................................................................................... 100 V / 230 VAC, 50/60 Hz 
Power Consumption @ 120 V .................................................................................. 16 W, 0.2 A max, 0.2 A inrush 
Power Consumption @ 230 V .................................................................................. 15 W, 0.1 A max, 0.2 A inrush 
Fuse ........................................................................................................................................................ F 1 A, 250 V 
 

 
LIGHT SOURCE 

LED (per pod) ..................................................................................... 112 (32 red, 48 green, 32 blue) 100,000 hrs 

 

PHOTO OPTIC 

Coverage Angle..................................................................................................................................................... 63° 
 

THERMAL 

Maximum ambient temperature ......................................................................................................... 104° F (40° C) 

 
ORDERING INFORMATION 

J-Six™ ................................................................................................................................................................ JSIX 
 

WARRANTY INFORMATION 

Warranty ................................................................................................................................ 1-year limited warranty 

Содержание J-Six

Страница 1: ...User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave 120 V 230 V Switchable Replaceable Fuse User Serviceable ...

Страница 2: ... AC POWER 3 Power Linking 4 CONTACT US 5 SAFETY INSTRUCTIONS 5 2 INTRODUCTION 6 FEATURES 6 PRODUCT OVERVIEW 6 MOUNTING 7 Orientation 7 Rigging 7 Fuse Replacement 7 3 OPERATING INSTRUCTIONS 7 STANDALONE MODE SOUND ACTIVE 7 4 APPENDIX 8 GENERAL MAINTENANCE 8 RETURNS PROCEDURE 8 CLAIMS 8 GENERAL TROUBLESHOOTING 9 TECHNICAL SPECIFICATIONS 9 ...

Страница 3: ... showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This manual uses the following icons to indicate information that requires special attention on the part of the user ICON MEANING This paragraph contains critical installation configuration or operation information Failure to comply with this information may...

Страница 4: ...re contains power linking via the edison outlet located next to the power input cable Please see the diagram below for further explanation The maximum quantity of fixtures that may be linked is 36 Additional power link out Fixture 1 Fixture 2 Fixture 3 ...

Страница 5: ...lled in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots are blocked Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by ...

Страница 6: ...ds rotate separately together and or against each other Built in sound activated programs Additional power output max 36 units Product Overview Hanging bracket Bracket adjustment knob Microphone sensitivity adjustment knob Voltage selection switch Power Out Microphone Power In Fuseholder ...

Страница 7: ...be exposed to rain high humidity extreme temperature changes or restricted ventilation Fuse Replacement 1 With a flat head screwdriver wedge the fuse holder out of its housing 2 Remove the damaged fuse from its holder and replace with exact same type fuse 3 Insert the fuse holder back in its place and reconnect power 3 OPERATING INSTRUCTIONS Standalone Mode Sound Active This mode allows a single u...

Страница 8: ...fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET ...

Страница 9: ...l and or external ü ü ü No light output Call service technician ü If you still have a problem after trying the above solutions please contact CHAUVET Technical Support Technical Specifications WEIGHT DIMENSIONS Length 11 3 in 287 mm Width 11 1 in 281 mm Height 7 2 in 182 mm Weight 6 9 lbs 3 2 kg POWER Manual Power Switch 100 V 230 VAC 50 60 Hz Power Consumption 120 V 16 W 0 2 A max 0 2 A inrush Po...

Отзывы: