background image

Technical Support 

 
Address: Service Dept. 
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) 
Support (Email): [email protected] 
Telephone: (954) 929-1115 - (Press 4) 
Fax: (954) 929-5560 - (Attention: Service) 
Website: http://www.chauvetlighting.com 

5.

 

A

PPENDIX

 

DMX Primer 

There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A 
fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user 
must assign a starting address on the fixture that indicates the first channel reserved in the controller. 
There are many different types of DMX controllable fixtures and they all may vary in the total number 
of channels required. Choosing a start address should be planned in advance. Channels should 
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is 
set incorrectly. You can however, control multiple fixtures of the same type using the same starting 
address as long as the intended result is that of unison movement or operation. In other words, the 
fixtures will be slaved together and all respond exactly the same.  

DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is 
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which 
the fixtures are connected is not important and has no effect on how a controller communicates to 
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures 
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The 
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET 
carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’) 

GrafXpress Basic Rackmount 

13 

1/11/2008 3:18 PM

 

Содержание GrafXpress

Страница 1: ...Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle GrafXpress USER MANUAL GrafXpress Basic Rackmount 1 1 11 2008 3 18 PM ...

Страница 2: ...NEL SUMMARY 5 PRODUCT OVERVIEW 6 4 SETUP 7 Quick Start 7 5 OPERATING INSTRUCTIONS 8 USB CONTROL 8 OPERATION 9 Sound Active Mode 9 DMX Mode 9 DMX CHANNEL VALUES 10 GENERAL TROUBLESHOOTING 12 TECHNICAL SUPPORT 13 6 APPENDIX 13 DMX PRIMER 13 GENERAL MAINTENANCE 14 RETURNS PROCEDURE 14 CLAIMS 14 TECHNICAL SPECIFICATIONS 15 GrafXpress Basic Rackmount 2 1 11 2008 3 18 PM ...

Страница 3: ...before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100V and 240V AC 50 60 Hz All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Warning Dam...

Страница 4: ...on slots are blocked Always disconnect from power source before connecting to computer Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to...

Страница 5: ...by Pangolin Includes Windows based user interface and software to create custom animations and or text Pull in bitmaps behind the tracing window Creates custom text and graphics cues Access to quick animations Change geometry and laser settings RCA audio input and ILDA DB 25 quad output female connections Easy animations in minutes DMX Channel Summary CHANNEL FUNCTION 1 Mode 2 Page 3 Scene 4 Speed...

Страница 6: ...tch DMX Signal Indicator Power Switch X Y Gain Knobs Rear Panel Status Indicator Lights USB Jack DMX Out ILDA Output 1 2 DB9 Interlock Connection ILDA Output 1 2 Invert Y Axis DMX In Invert X Axis Memory card slot Power Input RCA Sound Switch switch between audio input and internal microphone for sound activation Audio Input GrafXpress Basic Rackmount 6 1 11 2008 3 18 PM ...

Страница 7: ...r switch to the On position User interface will read GrafXpress 6 Verify that the Laser Ready indicator is lit If not lit press interlock button to sync 7 Insert the DB 9 connector into the DB 9 interlock connection applies to lasers with greater than a 5mW output and DB 9 interlock input 8 Clear area in front of laser 9 Turn laser projector power to the On position 10 Turn key switch to the On po...

Страница 8: ...nnect the USB cable from your PC to the GrafXpress Basic Remote 4 Power on the controller 5 A pop up window will appear requesting drivers 6 Select Install from a specific location 7 In the next screen click the Browse button and locate the folder titled USB Driver select that folder and click OK Once you click OK Windows will finish the plug n play installation and inform you if your device is re...

Страница 9: ... is present playback will end and the current playing cue will fade out until a new trigger is sent via the audio input and the sound source DMX Mode The GrafXpress functions can be accessed through multiple DMX modes All functions except emergency stop and sound activation can be controlled via DMX 512 In DMX mode the memory card page and cues are accessible in the same manner that gobos and colo...

Страница 10: ... 071 072 Ù 075 076 Ù 079 080 Ù 083 084 Ù 087 088 Ù 091 092 Ù 095 096 Ù 099 100 Ù 103 104 Ù 107 108 Ù 111 112 Ù 115 116 Ù 119 120 Ù 123 124 Ù 127 128 Ù 131 132 Ù 135 136 Ù 139 140 Ù 143 144 Ù 147 148 Ù 151 152 Ù 155 158 Ù 161 164 Ù 167 168 Ù 171 172 Ù 175 176 Ù 179 180 Ù 183 184 Ù 187 188 Ù 191 192 Ù 195 196 Ù 199 200 Ù 203 204 Ù 207 208 Ù 211 212 Ù 215 216 Ù 219 Cue Blackout Cue 1 Cue 2 Cue 3 Cue ...

Страница 11: ...ze Negative full size Positive Full Size 8 000 Ù 255 Y Size Negative full size Positive Full Size 9 000 Ù 255 Z Angle 0 360 10 000 Ù 255 X Position Left Center Right 11 000 Ù 255 Y Position Down Center Up 12 000 Ù 255 Visible Points None All points visible 13 000 Ù 031 032 Ù 255 Scan Rate Default 25 200 14 000 Ù 031 032 Ù 255 Z Angle Off Slow Fast 15 000 Ù 255 Reserved GrafXpress Basic Rackmount 1...

Страница 12: ...ts life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up 9 Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights 9 9 9 9 Moves slow Check 220 110v switch for proper setting 9 No flash Re ...

Страница 13: ...ixtures whose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain connection is wher...

Страница 14: ...he external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture B...

Страница 15: ... Height 3 5 in 89 mm Weight 2 lbs 0 9 kg CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 15 ORDERING INFORMATION GrafXpress GrafXpress WARRANTY INFORMATION Warranty 2 year limited warranty ...