Intimidator™ 2.0 HTI User Manual
6
2006-10-03/14:48
Lamp
exposed
Remove both thumbscrews
Lamp Installation
S1
S2
S
ETUP
Lamp
You will need to install a lamp prior to the initial operation of the fixture. An HTI-150W high intensity
discharge lamp is included.
Warning!
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp
with alcohol and wipe it with a lint free cloth before installation.
L A M P I N S T A L L A T I O N
1. Remove screws labeled (S1) and pull out
lamp socket plate.
2. If replacing the lamp, remove old lamp first.
3. Holding the new lamp by its base, align the
pins on the lamp with the small hole in the
socket and insert the lamp squarely until the
retaining clips on the lamp socket secure the
lamp tightly.
4. Clean the glass/envelope of the bulb with an
alcohol wipe or equivalent.
5. Holding the lamp socket plate, insert the tip of
the lamp into the fixture with extreme care.
Navigate the lamp all the way until it reaches
the reflector and the lamp base plate touches
the bottom plate of the fixture.
6. Align the screw holes and fasten the screws
back onto the lamp socket plate.
7. Turn the fixture on and adjust the lamp
alignment screws (S2) until the brightest most
even area of the beam is in the center of your
spot. It may be necessary for you to use a
controller in order to command the fixture to
display a white beam on a flat surface with no
colors.
Maximizing the life of your lamp
To ensure the longest and most efficient use of the lamp always wait
between 10 and 15 minutes before re-applying power after a shutdown.
Failure to do so could result in premature aging of the lamp and failure to
the electronics that drive it.