background image

 

Chauvet, 3000 N 29

th

 Ct, Hollywood, FL 33020 U.S.A  

(800) 762-1084 – (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com

 

2006-10-03/14:48 

 

 

 

Intimidator™ 2.0 HTI

DMX-616

USER MANUAL

Intimidator™ 2.0 HTI 

Содержание DMX-616 Intimidator 2.0 HTI

Страница 1: ...Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 10 03 14 48 Intimidator 2 0 HTI DMX 616 USER MANUAL Intimidator 2 0 HTI ...

Страница 2: ... installation 6 POWER 7 MOUNTING 8 Orientation 8 Rigging 8 MANUAL FOCUSING 8 FUSE REPLACEMENT 8 OPERATING INSTRUCTIONS 9 OPERATING MODES 9 Stand Alone 9 Master Slave 9 Master Slave settings 9 DMX Mode 9 Setting the starting address 9 CA 9 EASY CONTROLLER OPTIONAL 11 APPENDIX 12 DMX PRIMER 12 Fixture Linking 12 DMX CHANNEL VALUES 13 MAINTENANCE 13 RETURNS PROCEDURE 14 CLAIMS 14 PHOTOMETRIC 14 GENER...

Страница 3: ... this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not e...

Страница 4: ...in beat activated and automatic programs stand alone Double bracket yoke doubles as floor stand Surface coated mirror for optimum luminosity Automatically enters stand alone when no DMX signal is present Linkable via Master Slave Linkable with ELC models DMX 610A Insignia 2 0 DMX 605A Intimidator 2 0 Micro stepping motors Thermal switch Fan cooled Options Wired remote controllers CA 9 Easy Control...

Страница 5: ...timidator 2 0 HTI Mirror Scanner Hanging Yoke double bracketed for floor positioning Double bracketed yoke used for floor positions Lamp access cover Power Fuse compartment Microphone Sound Sensitivity Knob Voltage Switch Remote Controller Input DMX connectors Dipswitches ...

Страница 6: ...rt the lamp squarely until the retaining clips on the lamp socket secure the lamp tightly 4 Clean the glass envelope of the bulb with an alcohol wipe or equivalent 5 Holding the lamp socket plate insert the tip of the lamp into the fixture with extreme care Navigate the lamp all the way until it reaches the reflector and the lamp base plate touches the bottom plate of the fixture 6 Align the screw...

Страница 7: ...t up or down within the reflector 4 As you move in and out of optimum lamp focus you will see the hot spot either gets wider or narrower The goal is to either totally diminish the hot spot by having it widen and spread across the entire spot or moving the hot spot so that it covers as much of the beam spot area as possible Power Your product is equipped with switch selectable AC power setting Warn...

Страница 8: ...nce o Safety cables should always be used o Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Manual Focusing To adjust the focus please follow the instructions below 1 If operating in stand alone mode turn the music down so that the unit temporarily stops any activity 2 In DMX control mode create a static scene with...

Страница 9: ...elow MASTER SLAVE SETTINGS 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the ...

Страница 10: ...provide the start address Determining which switches to toggle ON given a specific start address can be accomplished in the following manner By subtracting the largest switch value possible from the selected start address which does not cause a negative number Example Starting Address Address 10 Pin 4 8 Pin 2 2 Total 10 Address 24 Pin 5 16 Pin 4 8 Total 24 Resolving address using simple math Addre...

Страница 11: ...utton Tap the Function button to step through the 11 colors then once more to step to the next gobo Blackout LED OFF Fast Mode The unit s movement Pan Tilt and Gobo Color is sound activated Press and hold the Function button to achieve the following results a Strobe in different colors and gobos b Synchronous strobe in white c Two light strobe in white color CA 9 Easy Controller Optional ...

Страница 12: ... of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 wh...

Страница 13: ...Yellow Green Pink UV Cyan Orange Magenta Tri Color Red White Blue Quad Color Color Spin Slow Fast 4 000 Ù 255 Pan 0 180 5 000 Ù 255 Tilt 0 90 Maintenance To maintain optimum performance and minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up redu...

Страница 14: ...ure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be ...

Страница 15: ...le bad lamp or fixture is overheating Lamp may be at end of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up 9 Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights 9 9 9 9 Motor...

Страница 16: ...IC Illuminance 1 800fc or 19 368lux 1 meter Beam Angle 12 THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 5A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 5 ORDERING INFORMATION Intimidator 2 0 HTI DMX 616 CA 9 Easy Controller C...