background image

 

DMX-355 User Manual 

2005-12-15/10:45

 

AC Voltage Switch 

 

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

 

1 x Oceana

 (DMX-355) 

 

Power cord with plug 

 

800w S120V800W or S230V800W lamp 

 

Warranty Card & Manual

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of 

the fixture or refer to the fixture

s specifications chart. A fixture

s listed current rating is its average 

current draw under normal conditions. All fixtures must be powered directly off a switched circuit and 

cannot be run off a rheostat (variable resistor) or dimmer circuit, 

even if the rheostat or dimmer channel is used solely for a 0% to 

100% switch. Before applying power to a fixture, check that the 

source voltage matches the fixture

s requirement. Check the fixture 

or device carefully to make sure that if a voltage selection switch 

exists that it is set to the correct line voltage you will use. 

Warning! 

Verify that the power select switch on your unit 
matches the line voltage applied. All fixtures must be connected to circuits with a 
suitable Earth Ground.  

Safety Instructions 

 

Please keep this User Guide for future consultation. If you 
sell the unit to another user, be sure that they also receive 
this instruction booklet. 

 

Always make sure that you are connecting to the proper 
voltage and that the line voltage you are connecting to is 
not higher than that stated on decal or rear panel of the 
fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to 
rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 

 

The unit must be installed in a location with adequate 
ventilation, at least 50cm from adjacent surfaces. Be sure 
that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or 
replacing lamp or fuse and be sure to replace with same 
lamp source. 

 

Secure fixture to fastening device using a safety chain. 
Never carry the fixture solely by its head. Use its carrying 
handles. 

 

Maximum ambient temperature is Ta: 40

°

. Do not operate 

fixture at temperatures higher than this.  

 

In the event of serious operating problem, stop using the 
unit immediately. Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to 
damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the 
same type spare parts. 

 

Don

t connect the device to a dimmer pack.

 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on the 
cord. 

 

Avoid direct eye exposure to lamp while it is on.  

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET. 

 

 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance? 

 

 

Содержание DMX-355

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 12 15 10 45 DMX 355 Oceana DMX Effect Light USER MANUAL ...

Страница 2: ...Y 4 PRODUCT OVERVIEW 5 SETUP 6 LAMP 6 Lamp installation 6 MOUNTING 7 Orientation 7 Rigging 7 FUSE REPLACEMENT 7 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 Master Slave settings 8 DMX Mode 8 Setting the starting address 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 MAINTENANCE 11 RETURNS PROCEDURE 12 CLAIMS 12 GENERAL TROUBLESHOOTING 13 TECHNICAL ...

Страница 3: ...ease keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock...

Страница 4: ...t blue and 20 dark blue Projects a wave like pattern of blue multi rays due to an exclusive S shaped linear lamp rotating on a horizontal axis Built in sound activated programs Automatically enters stand alone when no DMX signal is present Linkable via Master Slave Fan cooled Optional programmable controller Any universal DMX 512 controller DMX Channel Summary CHANNEL FUNCTION 1 Gobo Color 2 Strob...

Страница 5: ...ew Hanging Bracket Fan ventilation Lamp access DMX Address Dipswitches DMX Input Connector DMX Output Connector Sound sensitivity knob Wired remote controller Built in Microphone IEC power connector fuse compartment Safety Hook 115V 230V AC Voltage Switch ...

Страница 6: ...th bare hands If this happens clean the lamp with alcohol and wipe it with a lint free cloth before installation LAMP INSTALLATION 1 Remove all top cover screws located on the top outer edge lip which covers the fixture and lens housing 2 The linear lamp is held in place by tension provided by springs inside of both ceramic socket ends It is important to proceed with lamp removal and replacement v...

Страница 7: ...g the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables should always be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Fuse Replacement With a flat head screwdriver wedge t...

Страница 8: ...d all other units following The programs are constructed based on the control of four units An optional CH X controller connected to the first unit in the chain will allow a blackout function Connecting the DMX 355 for Master Slave operation does not require any menu or setting selections Simply connect each unit in a daisy like fashion using qualified 3 pin DMX cables as described below MASTER SL...

Страница 9: ...ing a fixture using the DMX 512 control protocol than I suggest jumping to the Appendix Section and read the heading DMX Primer It contains very useful information that will help you understand its use Set the start address using the group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each switch in the ON position will provide...

Страница 10: ...e fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while pi...

Страница 11: ...or and a soft brush to remove dust collected on external vents and internal components Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens Gently polish optical surfaces until they are free of haze and lint Do not ...

Страница 12: ...ping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise...

Страница 13: ...ible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor movements...

Страница 14: ... Hz AC input 3 prong IEC 60320 C14 male socket LAMPS S120V800W 800W 120V S230V800W 800W 230V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 7A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 2 ORDERING INFORMATION Oceana DMX 355 ...

Отзывы: