DMX-355 User Manual
6
2005-12-15/10:45
DMX-355 Lamp Installation
Remove top cover
screws to expose lamp.
Lamp exposed
Screws also located
on opposite side.
S
ETUP
Lamp
You will need to install a lamp prior to the initial operation of the fixture. An 800W halogen lamp is
included.
Warning!
When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp
with alcohol and wipe it with a lint free cloth before installation.
L AM P I N ST AL L AT I O N
1)
Remove all top cover screws located
on the top outer edge lip which covers
the fixture and lens housing.
2)
The linear lamp is held in place by
tension provided by springs inside of
both ceramic socket ends. It is
important to proceed with lamp
removal and replacement very
delicately.
3)
Hold linear lamp with a napkin and
push in the direction of either of the
two ends to relieve tension on the
opposite end. Then pull end of lamp
upwards to remove from socket.
4)
To replace lamp, follow the same
procedure as above to insert lamp into
the socket.
5)
Replace top cover.