Product at a 

Glance 

Use on Dimmer 

 

Auto Programs 

 

Outdoor Use 

 

Auto-ranging Power Supply 

 

Sound Activated 

 

Replaceable Fuse 

 

DMX 

 

User Serviceable 

 

Master/Slave 

 

Duty Cycle 

 

 

 

Safety Notes 

Please read the following notes carefully 

before 

starting to work with this product. They 

include important safety information about its installation, usage, and maintenance. 

 

 

 

  Always connect this product to a grounded circuit to avoid the risk of electrocution. 

  Always disconnect this product from the power source before cleaning it or replacing 

the fuse. 

  Avoid direct eye exposure to the light source while the fixture is on. 

  Make sure the power cord is not crimped or damaged. 

  Never disconnect this product from power cord by pulling or tugging on the cord. 

  If mounting this product overhead, always secure it to a fastening device using a 

safety cable. 

  Make sure there are no flammable materials close to the unit while operating. 

  Do not touch this product’s housing when operating because it may be very hot.  

 

 

 

  Always make sure that the voltage of the outlet to which you are connecting this 

product is within the range stated on the decal or rear panel of the fixture. 

  This product is for indoor use only! (IP20) To prevent risk of fire or shock, do not 

expose this fixture to rain or moisture. 

  Always install this product in a location with adequate ventilation, at least 20 in (50 

cm) from adjacent surfaces.  

  Be sure that no ventilation slots on the unit’s housing are blocked. 

  Never connect this product to a dimmer pack. 

  Make sure to replace the fuse with another of the same type and rating. 

  Never carry this product from the power cord or any moving part. Always use the 

hanging/mounting bracket or the handles. 

  The maximum ambient temperature (Ta) is 104° F (40° C). Do not operate this 

product at higher temperatures.  

  In the event of a serious operating problem, stop using the unit immediately.  

  Never try to repair this product. Repairs carried out by unskilled people can lead to 

damage or malfunction. Please contact the nearest authorized technical assistance 

center. 

 

 

 

  Keep this User Manual for future consultation. If you sell this product to another user, 

be sure that they also receive this document. 

 

 

Содержание DMF-10

Страница 1: ...User Manual ...

Страница 2: ... Orientation 9 Rigging 9 4 Operation 10 Control Panel Operation 10 Menu Map 10 Configuration DMX 11 Starting Address 11 DMX Channel Assignments and Values 11 6 CH 11 Configuration Standalone 12 Sound Active Mode 12 Automatic Mode 12 Master Slave Mode 12 5 Technical Information 13 Fixture Maintenance 13 General Troubleshooting 14 Contact Procedure 15 CHAUVET Contact Information 15 Returning Product...

Страница 3: ...ption not to be modified for example showing the operating mode current status Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the fixture s control panel ON A value to be entered or selected Icons Icon Meaning This paragraph contains critical installation configuration or operation information Failure to comply with this information may render the fixture part...

Страница 4: ...use it may be very hot Always make sure that the voltage of the outlet to which you are connecting this product is within the range stated on the decal or rear panel of the fixture This product is for indoor use only IP20 To prevent risk of fire or shock do not expose this fixture to rain or moisture Always install this product in a location with adequate ventilation at least 20 in 50 cm from adja...

Страница 5: ...DMF 10 User Manual Rev 01e Page 5 of 18 2 INTRODUCTION Product Overview Power Out Safety Microphone DMX Out DMX In Power In Microphone Sensitivity Knob Fuse Holder LED Screen ...

Страница 6: ...Page 6 of 18 DMF 10 User Manual Rev 01e Product Dimensions ...

Страница 7: ...ectrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement This fixture uses an F 2 A 250 V fuse Follow the instructions below to change it in case it blows Disconnect this product from the power outlet before replacing the fuse 1 Wedge the tip of a flat head screwdriver i...

Страница 8: ...m You can power link up to 24 DMF 10 units on 120 VAC or up to 44 DMF 10 units on 230 VAC The power linking diagram shown above corresponds to the North American version of this product ONLY If using this product in other markets you must consult with the local CHAUVET distributor as power linking connectors and requirements may differ in your country or region 1 st Fixture 2nd Fixture 3 rd Fixtur...

Страница 9: ...of this manual for weight information When mounting this product overhead always use a safety cable Mount the fixture securely to a rigging point whether an elevated platform or a truss When rigging this product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When power linking multiple fixtures you must...

Страница 10: ...ction MENU Press to find an operation mode or to back out of the current menu option UP Press to scroll up the list of options or to find a higher value DOWN Press to scroll down the list of options or to find a lower value ENTER Press to activate a menu option or a selected value Menu Map Mode Programming Steps Description DMX Mode D001 512 512 Selects the DMX starting address Automatic Mode AUTO...

Страница 11: ... to 6 DMX channels in DMX mode which defines the highest configurable address to 507 If you are not familiar with the DMX protocol you may refer to the DMX Primer section in the Technical Information chapter To select the starting address do the following 1 Press MENU repeatedly until 512 shows on the display 2 Press ENTER 3 Use UP or DOWN to select the starting address 4 Press ENTER DMX Channel A...

Страница 12: ...ws a single DMF 10 unit the master to control the actions of one or more DMF 10 units the slaves without the need of a DMX controller The master unit will be set to operate in either Automatic or Sound Active mode while the slave units will be set to operate in Slave Mode Once set and connected the slave units will operate in unison with the master unit Configure the units as indicated below Slave...

Страница 13: ... contributing factors to increase the cleaning frequency To clean this fixture follow the instructions below Unplug the fixture from power Wait until the fixture is cold Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents Clean the lens with a mild soap solution ammonia free glass cleaner or isopropyl alcohol Apply the solution directly to a s...

Страница 14: ...ight fader s on the controller Wrong DMX personality on the fixture Set the correct DMX fixture s personality Assign the faders accordingly Wrong polarity setting on the DMX controller Change the signal polarity on the controller Loose or damaged DMX cable Check the DMX cable before the faulty unit Internal problem Send product for repair Intermittent DMX Problems Signal cables are not DMX compati...

Страница 15: ...e US United Kingdom or Ireland contact your distributor of record and follow their instructions on how to return CHAUVET products to them Visit our Web site for contact details Returning Products to CHAUVET Call the corresponding CHAUVET Tech Support office and request a Return Merchandise Authorization RMA number before shipping the fixture Be prepared to provide the model number serial number an...

Страница 16: ...control fixture A This means that the user should assign the starting address of fixture B to 005 or higher For a starting address of 005 the DMX controller would use channels 005 to 010 to control fixture B It is possible to control multiple fixtures of the same type by assigning each one of them the same starting address In this case all the fixtures would respond in unison synchronized to the s...

Страница 17: ... on the other end The DMX protocol indicates that the XLR connectors must have five pins However most lighting fixtures use the 3 pin XLR connector The pin assignment of the 3 pin and 5 pin XLR connectors in a DMX cable is as follows Male Plug Female Plug Signal 3 Pin 5 Pin 5 Pin 3 Pin Signal Common 1 1 1 1 Common Data 2 2 2 2 Data Data 3 3 3 3 Data Not used 4 4 Not used Not used 5 5 Not used You ...

Страница 18: ... 2 A Power linking current units 8 A 24 units 8 A 44 units Fuse F 2 A 250 V F 2 A 250 V Power I O US Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison US Local plug Light Source Type Power Lifespan 1 quad color LED 27 W 50 000 hours Color Quantity Current Red 1 2 2 A Green 1 2 1 A Blue 1 2 2 A White 1 1 2 A Photo Optic Parameter Value Covera...

Отзывы: