background image

 

 

 

 

DMF-10 User Manual (Rev. 01e) 

Page 17 of 18 

DMX Cabling 

The  DMX  protocol  requires  using  special  data  cables  to  accommodate  for  the  high 

speed  digital  signals  it  uses.  Despite  their  apparent  similarities,  data  cables  are 

electrically  different  from  standard  microphone  cables  because  they  can  carry  high 

frequency  digital  signals  and  have  better  protection  against  electromagnetic 

interference.  You  can  purchase  CHAUVET®  certified  DMX  cables  directly  from  a 

dealer/distributor or make your own DMX cable.  
If you choose to make your own DMX cable, you must use a data-grade cable such as 

the Belden 9841, which has the following electrical characteristics: 

Type: 

shielded, 2-conductor twisted pair 

Maximum capacitance between conductors: 

30 pF/ft 

Maximum capacitance between conductor and shield: 

55 pF/ft 

Maximum resistance: 

20 ohms/1000 ft 

Nominal impedance: 

100~140 ohms 

 

 

 

DMX Connectors 

Each  DMX  cable  must  have  a  male  XLR  connector  on  one  end  and  a  female  XLR 

connector on the other end. The DMX protocol indicates that the XLR connectors must 

have five pins. However, most lighting fixtures use the 3-pin XLR connector. The pin 

assignment of the 3-pin and 5-pin XLR connectors in a DMX cable is as follows: 

 

Male Plug 

 

Female Plug 

Signal 

3-Pin 

 

5-Pin 

 

5-Pin 

 

3-Pin 

Signal 

Common 

 

 

 

Common 

 

 

 

Data - 

 

 

 

Data - 

 

 

 

Data + 

 

 

 

Data + 

 

 

 

Not used 

 

 

 

 

 

Not used 

 

 

 

Not used 

 

 

 

 

 

Not used 

 

 

 

 

 

 

 

 

 

 

 

 

You can use the above table to create a 3-pin/3-pin cable, a 5-pin/5-pin cable, or a 3-

pin to 5-pin adapter. 
The  DMX  daisy  chain  uses  a  terminator  to  reduce  signal  transmission  problems, 

especially with long cables. The terminator consists of either a 3-pin or 5-pin XLR male 

plug with a 120 Ω, ¼ W resistor connected to the wire side of pins 2 and 3, as shown 

below.  

 

 

 

 

 

 

 

 

 

 

 

 

The  terminator  plug  connects  to  the  DMX  Out  socket  of  the  last  DMX  fixture  in  the 

daisy chain. 

 

 

 

Do not allow the common wire of the DMX cable to touch the fixture’s chassis 

ground.  This  could  cause  a  ground  loop,  which  may  affect  your  fixtures’ 

performance. Test all DMX cables with an ohmmeter to verify the correct polarity 

of  the  wires,  and  to  make  sure  that  they  are  not  touching  the  shield  or  each 

other. 

Содержание DMF-10

Страница 1: ...User Manual ...

Страница 2: ... Orientation 9 Rigging 9 4 Operation 10 Control Panel Operation 10 Menu Map 10 Configuration DMX 11 Starting Address 11 DMX Channel Assignments and Values 11 6 CH 11 Configuration Standalone 12 Sound Active Mode 12 Automatic Mode 12 Master Slave Mode 12 5 Technical Information 13 Fixture Maintenance 13 General Troubleshooting 14 Contact Procedure 15 CHAUVET Contact Information 15 Returning Product...

Страница 3: ...ption not to be modified for example showing the operating mode current status Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the fixture s control panel ON A value to be entered or selected Icons Icon Meaning This paragraph contains critical installation configuration or operation information Failure to comply with this information may render the fixture part...

Страница 4: ...use it may be very hot Always make sure that the voltage of the outlet to which you are connecting this product is within the range stated on the decal or rear panel of the fixture This product is for indoor use only IP20 To prevent risk of fire or shock do not expose this fixture to rain or moisture Always install this product in a location with adequate ventilation at least 20 in 50 cm from adja...

Страница 5: ...DMF 10 User Manual Rev 01e Page 5 of 18 2 INTRODUCTION Product Overview Power Out Safety Microphone DMX Out DMX In Power In Microphone Sensitivity Knob Fuse Holder LED Screen ...

Страница 6: ...Page 6 of 18 DMF 10 User Manual Rev 01e Product Dimensions ...

Страница 7: ...ectrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement This fixture uses an F 2 A 250 V fuse Follow the instructions below to change it in case it blows Disconnect this product from the power outlet before replacing the fuse 1 Wedge the tip of a flat head screwdriver i...

Страница 8: ...m You can power link up to 24 DMF 10 units on 120 VAC or up to 44 DMF 10 units on 230 VAC The power linking diagram shown above corresponds to the North American version of this product ONLY If using this product in other markets you must consult with the local CHAUVET distributor as power linking connectors and requirements may differ in your country or region 1 st Fixture 2nd Fixture 3 rd Fixtur...

Страница 9: ...of this manual for weight information When mounting this product overhead always use a safety cable Mount the fixture securely to a rigging point whether an elevated platform or a truss When rigging this product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When power linking multiple fixtures you must...

Страница 10: ...ction MENU Press to find an operation mode or to back out of the current menu option UP Press to scroll up the list of options or to find a higher value DOWN Press to scroll down the list of options or to find a lower value ENTER Press to activate a menu option or a selected value Menu Map Mode Programming Steps Description DMX Mode D001 512 512 Selects the DMX starting address Automatic Mode AUTO...

Страница 11: ... to 6 DMX channels in DMX mode which defines the highest configurable address to 507 If you are not familiar with the DMX protocol you may refer to the DMX Primer section in the Technical Information chapter To select the starting address do the following 1 Press MENU repeatedly until 512 shows on the display 2 Press ENTER 3 Use UP or DOWN to select the starting address 4 Press ENTER DMX Channel A...

Страница 12: ...ws a single DMF 10 unit the master to control the actions of one or more DMF 10 units the slaves without the need of a DMX controller The master unit will be set to operate in either Automatic or Sound Active mode while the slave units will be set to operate in Slave Mode Once set and connected the slave units will operate in unison with the master unit Configure the units as indicated below Slave...

Страница 13: ... contributing factors to increase the cleaning frequency To clean this fixture follow the instructions below Unplug the fixture from power Wait until the fixture is cold Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents Clean the lens with a mild soap solution ammonia free glass cleaner or isopropyl alcohol Apply the solution directly to a s...

Страница 14: ...ight fader s on the controller Wrong DMX personality on the fixture Set the correct DMX fixture s personality Assign the faders accordingly Wrong polarity setting on the DMX controller Change the signal polarity on the controller Loose or damaged DMX cable Check the DMX cable before the faulty unit Internal problem Send product for repair Intermittent DMX Problems Signal cables are not DMX compati...

Страница 15: ...e US United Kingdom or Ireland contact your distributor of record and follow their instructions on how to return CHAUVET products to them Visit our Web site for contact details Returning Products to CHAUVET Call the corresponding CHAUVET Tech Support office and request a Return Merchandise Authorization RMA number before shipping the fixture Be prepared to provide the model number serial number an...

Страница 16: ...control fixture A This means that the user should assign the starting address of fixture B to 005 or higher For a starting address of 005 the DMX controller would use channels 005 to 010 to control fixture B It is possible to control multiple fixtures of the same type by assigning each one of them the same starting address In this case all the fixtures would respond in unison synchronized to the s...

Страница 17: ... on the other end The DMX protocol indicates that the XLR connectors must have five pins However most lighting fixtures use the 3 pin XLR connector The pin assignment of the 3 pin and 5 pin XLR connectors in a DMX cable is as follows Male Plug Female Plug Signal 3 Pin 5 Pin 5 Pin 3 Pin Signal Common 1 1 1 1 Common Data 2 2 2 2 Data Data 3 3 3 3 Data Not used 4 4 Not used Not used 5 5 Not used You ...

Страница 18: ... 2 A Power linking current units 8 A 24 units 8 A 44 units Fuse F 2 A 250 V F 2 A 250 V Power I O US Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison US Local plug Light Source Type Power Lifespan 1 quad color LED 27 W 50 000 hours Color Quantity Current Red 1 2 2 A Green 1 2 1 A Blue 1 2 2 A White 1 1 2 A Photo Optic Parameter Value Covera...

Отзывы: