background image

 

COLORmist

 System User Manual 

12 

 

2005-10-10/18:36

 

132 feet (40.2m) length (MAXIMUM LENGTH) 

MIST-CBL33 
33

 (10m) cables 

MIST-PS8 
Power Unit 

MIST-PAR80 or MIST-PANEL 

120 feet (36.5m) length 

MIST-CBL15 
15

 (4.5m) cables 

MIST-PS8 
Power Unit 

MIST-PAR80 or MIST-PANEL 

60 feet (18.2m) length (MAXIMUM QUANTITY) 

MIST-CBL5 
5

 (1.5m) cables 

MIST-PS8 
Power Unit 

MIST-PAR80 or MIST-PANEL 

12 

11 

10 

Any combination of cables and LED fixtures can be sought so long as the run does not 
exceed 132 feet with a maximum of 4 fixtures or a maximum of 12 fixtures at no longer 
length than 60 feet. 

MIST-PS8 (Power Unit) Configurations 

The MIST-PS8 provides power to both the Panel and Par LED fixtures. The diagram below illustrates 
the number of fixtures along with the cable length the power unit is capable of accommodating.  

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products 
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the 
fixture. Be prepared to provide the model number, serial number and a brief description of the cause 
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate 
packaging is the customer

s responsibility. CHAUVET reserves the right to use its own discretion to 

repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe 
method to use. 

Claims 

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and 
submit claims with the shipper in the event that a fixture is damaged due to shipping.  Any other claim 
for items such as missing component/part, damage not related to shipping, and concealed damage, 
must be made within seven (7) days of receiving merchandise.  

Содержание COLORMIST MIST-CON

Страница 1: ... 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 10 10 18 36 COLORmist System MIST PAR80 COLORmist Par MIST PANEL COLORmist Panel MIST CON COLORmist Controller MIST PS8 COLORmist Power Unit USER MANUAL ...

Страница 2: ...IST PAN 6 OPERATING INSTRUCTIONS 7 CONTROL PANEL 7 MENU DIAGRAM 7 SYSTEM SETUP 7 Initial Setup 7 Re initialization 7 SINGLE ACTION PROGRAMS 8 Choosing Single Action Programs 8 DMX CONTROL MODE 9 Setting the DMX address 9 Running in DMX Mode 9 Daisy Chain Connection 9 SYSTEM CONFIGURATION CONNECTION 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 MIST PS8 POWER UNIT CONFIGURATI...

Страница 3: ...tage selection switch exists that it is set to the correct line voltage you will use Warning If applicable verify that the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground Safety Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive...

Страница 4: ... 24 Ultra bright LED s Stand alone color change programs using COLORmist Power unit 7 static colors 13 color pattern chase programs with adjustable speeds auto run sound active mode and RGB Mix via MIST CON COLORmistTM Controller Low power consumption and heat generation No infra red or UV emissions Up to 100 000 hour LED life span Master Slave mode requires COLORmist Power unit MIST PAR80 and MIS...

Страница 5: ...X input connector C Power and Signal output D DC input External Power Supply C D COLORmist Controller Rear Panel COLORmist Hanging yoke Input and Output 4 conductor connectors Used for both power and signal COLORmist Power 8 AC Voltage Switch Power connector Fuse compartment 4 conductor connectors provide signal and power continuation for daisy chained fixtures COLORmist Rear Panel COLORmist Power...

Страница 6: ...ure check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATIONAL BROWN Live L BLUE Neutral N YELLOW GREEN Earth EG Ground Mounting MIST PAR80 Orientation This fixture can be mounted on a truss using a clamp in any position or on a strut system for track style lighting Riggin...

Страница 7: ...he display shows M System Setup 2 Press the SETUP button then the UP button once It will show 3 Lamp Amount 3 Press the SETUP button to enter the function A number will now appear to the right of the text as shown here in an example 3 Lamp Amount 34 4 Use the UP and DOWN buttons to locate a number between 0 and 250 This represents the number of fixtures connected 5 Press the MODE button to set thi...

Страница 8: ...Run Speed Flash Speed Select Color Combination 1 20 2 Color Flow Auto Run Speed Flash Speed Select Color Combination 1 21 Any Color RGB Color Mix Red Green Blue 22 Color Fade Auto Run Speed 23 Auto Run Auto Run Speed runs all built in programs 1 Refer to DMX Channel Values for Color Combinations Table Choosing Single Action Programs 1 Press the MODE button until the display shows M System Setup 2 ...

Страница 9: ...nnel values The next step may require you to create a device profile within your lighting controller Proceed to section DMX Channel Values for a detailed chart of the control values for each channel of DMX Running in DMX Mode If the control panel menu displays 1 Dmx Ch press SETUP to activate DMX control mode For instructions on arriving at this menu item repeat the instructions Setting the DMX ad...

Страница 10: ...f one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whil...

Страница 11: ...cond 2 000 255 Any Color Active Red Intensity 0 100 000 002 003 249 250 255 Flash Speed Always On Slow Fast Blackout 3 000 255 Any Color Active Green Intensity 0 100 000 012 013 025 026 038 039 051 052 064 065 077 078 090 091 103 104 116 117 129 130 142 143 155 156 168 169 181 182 194 195 207 208 220 221 233 234 246 247 255 Color Combinations Red Green Red Yellow Red Blue Red Purple Red Cyan Red W...

Страница 12: ...nd in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack fixture any shipping dama...

Страница 13: ...8 38 in Height 47 63 mm 1 88 in Weight 0 70 Kgs 1 55 lbs Power 12V DC 800mA Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT Channels 4 ORDERING INFORMATION COLORmist MIST PAR80 COLORmist Panel MIST PANEL COLORmist Power 8 MIST PS8 COLORmist Controller MIST CON COLORmist Power Signal Cable 3...

Отзывы: