background image

 

COLORmist

 System User Manual 

 

2005-10-10/18:36

 

M System Setup 

M Single Action 

Main Menu 

1 DMX Ch 

(0 

 508) 

2 Set Address  (N / A) 
3 Lamp Amount  (0 

 250) 

For a detailed listing of Single 

Action programs proceed to the 

next page. 

O

PERATING 

I

NSTRUCTIONS

 

Control Panel 

 
On the control panel you can set the controller for single action mode where preset programs are run 
either statically, automatically or by sound-activation or assign a starting DMX channel address.   

Menu Diagram 

System Setup 

 
You will need to let the controller be aware of the number of par cans and/or panels connected in 
series. This is essential in order for the chase and flow programs to perform correctly through out the 
entire stretch of fixtures.  

I n i t i a l   S e t u p  

1.  Press the MODE button until the display shows 

M System Setup

2.  Press the SETUP button then the UP button once. It will show 

3 Lamp Amount

3.  Press the SETUP button to enter the function. A number will now appear to the right of the text as 

shown here in an example. 

3 Lamp Amount  34

4.  Use the UP and DOWN buttons to locate a number between 0 and 250. This represents the 

number of fixtures connected.  

5.  Press the MODE button to set this function. 

R e - i n i t i a l i z a t i o n  

Whenever a fixture is removed, replaced or exchanged please follow the following instructions. 
 
1.  Press the MODE button until the display shows 

M System Setup

2.  Press the SETUP button then the UP button twice. It will show 

2 Set Address

3.  Press the SETUP button to re-initialize. 

4.  Proceed to prior instruction 

Initial Setup

 and re-do. 

 

 
 
 

MENU 

SETUP 

UP 

DOWN 

[MENU] Returns to Main menu or step backward through functions 

[SET UP] Enters menu selection 

[UP] Steps backward through menu selection 

[DOWN] Steps forward through menu selection 

Содержание COLORMIST MIST-CON

Страница 1: ... 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 10 10 18 36 COLORmist System MIST PAR80 COLORmist Par MIST PANEL COLORmist Panel MIST CON COLORmist Controller MIST PS8 COLORmist Power Unit USER MANUAL ...

Страница 2: ...IST PAN 6 OPERATING INSTRUCTIONS 7 CONTROL PANEL 7 MENU DIAGRAM 7 SYSTEM SETUP 7 Initial Setup 7 Re initialization 7 SINGLE ACTION PROGRAMS 8 Choosing Single Action Programs 8 DMX CONTROL MODE 9 Setting the DMX address 9 Running in DMX Mode 9 Daisy Chain Connection 9 SYSTEM CONFIGURATION CONNECTION 9 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 MIST PS8 POWER UNIT CONFIGURATI...

Страница 3: ...tage selection switch exists that it is set to the correct line voltage you will use Warning If applicable verify that the power select switch on your unit matches the line voltage applied All fixtures must be connected to circuits with a suitable Earth Ground Safety Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive...

Страница 4: ... 24 Ultra bright LED s Stand alone color change programs using COLORmist Power unit 7 static colors 13 color pattern chase programs with adjustable speeds auto run sound active mode and RGB Mix via MIST CON COLORmistTM Controller Low power consumption and heat generation No infra red or UV emissions Up to 100 000 hour LED life span Master Slave mode requires COLORmist Power unit MIST PAR80 and MIS...

Страница 5: ...X input connector C Power and Signal output D DC input External Power Supply C D COLORmist Controller Rear Panel COLORmist Hanging yoke Input and Output 4 conductor connectors Used for both power and signal COLORmist Power 8 AC Voltage Switch Power connector Fuse compartment 4 conductor connectors provide signal and power continuation for daisy chained fixtures COLORmist Rear Panel COLORmist Power...

Страница 6: ...ure check that the source voltage matches the fixture s requirement All fixtures must be connected to circuits with a suitable Earth Ground Power Cable Configuration CABLE PIN INTERNATIONAL BROWN Live L BLUE Neutral N YELLOW GREEN Earth EG Ground Mounting MIST PAR80 Orientation This fixture can be mounted on a truss using a clamp in any position or on a strut system for track style lighting Riggin...

Страница 7: ...he display shows M System Setup 2 Press the SETUP button then the UP button once It will show 3 Lamp Amount 3 Press the SETUP button to enter the function A number will now appear to the right of the text as shown here in an example 3 Lamp Amount 34 4 Use the UP and DOWN buttons to locate a number between 0 and 250 This represents the number of fixtures connected 5 Press the MODE button to set thi...

Страница 8: ...Run Speed Flash Speed Select Color Combination 1 20 2 Color Flow Auto Run Speed Flash Speed Select Color Combination 1 21 Any Color RGB Color Mix Red Green Blue 22 Color Fade Auto Run Speed 23 Auto Run Auto Run Speed runs all built in programs 1 Refer to DMX Channel Values for Color Combinations Table Choosing Single Action Programs 1 Press the MODE button until the display shows M System Setup 2 ...

Страница 9: ...nnel values The next step may require you to create a device profile within your lighting controller Proceed to section DMX Channel Values for a detailed chart of the control values for each channel of DMX Running in DMX Mode If the control panel menu displays 1 Dmx Ch press SETUP to activate DMX control mode For instructions on arriving at this menu item repeat the instructions Setting the DMX ad...

Страница 10: ...f one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whil...

Страница 11: ...cond 2 000 255 Any Color Active Red Intensity 0 100 000 002 003 249 250 255 Flash Speed Always On Slow Fast Blackout 3 000 255 Any Color Active Green Intensity 0 100 000 012 013 025 026 038 039 051 052 064 065 077 078 090 091 103 104 116 117 129 130 142 143 155 156 168 169 181 182 194 195 207 208 220 221 233 234 246 247 255 Color Combinations Red Green Red Yellow Red Blue Red Purple Red Cyan Red W...

Страница 12: ...nd in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RA Products returned without an RA will be refused Call CHAUVET and request RA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack fixture any shipping dama...

Страница 13: ...8 38 in Height 47 63 mm 1 88 in Weight 0 70 Kgs 1 55 lbs Power 12V DC 800mA Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT Channels 4 ORDERING INFORMATION COLORmist MIST PAR80 COLORmist Panel MIST PANEL COLORmist Power 8 MIST PS8 COLORmist Controller MIST CON COLORmist Power Signal Cable 3...

Отзывы: