WEIGHT & DIMENSIONS 
Length................................................................................................................... 247.65 mm (9.75 in) 
Width................................................................................................................... 260.35 mm (10.25 in) 
Height ................................................................................................................... 215.90 mm (8.50 in) 
Weight................................................................................................................... 9.04 Kgs (19.75 lbs) 
 
POWER 
Switch selectable power................................................................................115V 60Hz or 230V 50Hz 
AC input .......................................................................................................... 3-prong IEC 60320 C14 
 
DUTY CYCLE (RECOMMENDED) 
1. Fixture ON............................................................................................... (not to exceed) 15 minutes 
2. Fixture OFF............................................................................................. (cool down for) 15 minutes 
 
LAMPS 
EHJ...................................................................................................................................... 250W 24V 
 
THERMAL 
Maximum ambient temperature ......................................................................................... 40

° (104° F)

 

 
FUSE 
Main ................................................................................................... 20mm Glass 3A 250V Fast Blow 
PCB1 ................................................................................................. 20mm Glass 3A 250V Fast Blow 
PCB2 ................................................................................................. 20mm Glass 3A 250V Fast Blow 
 
ORDERING INFORMATION 
Scrambler

. ............................................................................................................................ CH-244 

Fuse 3A ........................................................................................................................ P170FUSE003 

Technical Support 

Address: 

Service Dept. 

 

3000 N 29

th

 Ct, Hollywood, FL 33020 (U.S.A.) 

Support (Email):  

[email protected]

 

Telephone: 

(954) 929-1115 - (Press 4) 

Fax: 

(954) 929-5560 - (Attention: Service) 

Website: 

http://www.chauvetlighting.com 

 
 

Содержание CH-244

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 11 15 13 03 CH 244 Scrambler USER MANUAL ...

Страница 2: ...ER 3 SAFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 PRODUCT OVERVIEW 4 SETUP 5 LAMP 5 Lamp installation 5 MOUNTING 5 Orientation 5 Rigging 5 FUSE REPLACEMENT 5 OPERATING INSTRUCTIONS 6 Duty Cycle recommended 6 APPENDIX 7 GENERAL MAINTENANCE 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 8 TECHNICAL SPECIFICATIONS 9 TECHNICAL SUPPORT 9 ...

Страница 3: ... to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flam...

Страница 4: ...d active zones comprised of 2 dishes each with independent sound sensitivity knobs Built in microphone Efficient use of 1 bulb to produce 4 moonflowers Safety hook Fan cooled Product Overview Remove these two screws and pull out lamp plate to change lamp Hanging Yoke Safety hook Zone 1 Sound sensitivity knob Built in microphone Power Fuse Zone 2 Sound sensitivity knob Voltage select switch ...

Страница 5: ...pull out of the lamp socket located inside the reflector 5 Replace with a new lamp 6 Replace lamp plate align the screw holes and fasten the screws Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp Adjust the angle of...

Страница 6: ... the Scrambler and any other non dimmable effect light from a switch panel Make sure to use a cable of at least 25 feet to provide ample distance between the control panel and the switch pack for most mobile lighting applications If you would prefer to control it directly from your DMX lighting console then we suggest a DMX compatible relay switch pack These devices are an extremely affordable sol...

Страница 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Страница 8: ...ly in order to measure correctly check to see if perhaps it is stuck Fogger or Snow output has dropped Clean with distilled water and vinegar Replace hose Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick st...

Страница 9: ...not to exceed 15 minutes 2 Fixture OFF cool down for 15 minutes LAMPS EHJ 250W 24V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 3A 250V Fast Blow PCB1 20mm Glass 3A 250V Fast Blow PCB2 20mm Glass 3A 250V Fast Blow ORDERING INFORMATION Scrambler CH 244 Fuse 3A P170FUSE003 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetli...

Отзывы: