background image

 

CH-244 User Manual 

2005-11-15/13:03 

S1 

Lamp plate 

 Hanging Clamp 

 The fuse is located 
inside this 
compartment. 
Remove using a flat 
head screwdriver. 

S

ETUP

 

Lamp 

You may need to install a lamp prior to the initial operation of the fixture. An EHJ 250W halogen lamp 

is included. This lamp is used for both the 115V and 230V settings. 

Warning!  When replacing the lamp, please wait 15 minutes after powering down to allow the unit to 

cool down! Always disconnect from main power prior to lamp replacement.  

Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp 

with alcohol and wipe it with a lint free cloth before installation. 

L AM P   I N ST AL L AT I O N  

1) 

Remove the two (S1) screws located in front 
of the fixture as shown in the image.  

2) 

Pull the lamp plate out exposing the lamp 
and socket. (not shown)  

3) 

If replacing the lamp, remove old lamp first. 

4) 

Using a cloth or napkin hold the bulb and 
pull out of the lamp socket located inside the 
reflector. 

5) 

Replace with a new lamp. 

6) 

Replace lamp plate, align the screw holes 
and fasten the screws. 

Mounting 

O R I E N T AT I O N  

This fixture may be mounted in any position provided there is adequate room for ventilation.  

R I G G I N G    

It is important never to obstruct the fan or vents pathway. Mount the fixture using, a suitable 

C

 or 

O

 

type clamp. Adjust the angle of the fixture by loosening both knobs and tilting the fixture. After finding 

the desired position, retighten both knobs. 

 

When selecting installation location, take into consideration lamp 
replacement access and routine maintenance.  

 

Safety cables should always be used.  

 

Never mount in places where the fixture will be exposed to rain, high 
humidity, extreme temperature changes or restricted ventilation. 

Fuse Replacement 

Disconnect the power cord before replacing a fuse and always replace with the same type fuse. 

With a flat head screwdriver wedge the fuse 
holder out of its housing. Remove the damaged 
fuse from its holder and replace with exact 
same type fuse. Insert the fuse holder back in 
its place and reconnect power.  

Содержание CH-244

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 11 15 13 03 CH 244 Scrambler USER MANUAL ...

Страница 2: ...ER 3 SAFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 PRODUCT OVERVIEW 4 SETUP 5 LAMP 5 Lamp installation 5 MOUNTING 5 Orientation 5 Rigging 5 FUSE REPLACEMENT 5 OPERATING INSTRUCTIONS 6 Duty Cycle recommended 6 APPENDIX 7 GENERAL MAINTENANCE 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 8 TECHNICAL SPECIFICATIONS 9 TECHNICAL SUPPORT 9 ...

Страница 3: ... to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flam...

Страница 4: ...d active zones comprised of 2 dishes each with independent sound sensitivity knobs Built in microphone Efficient use of 1 bulb to produce 4 moonflowers Safety hook Fan cooled Product Overview Remove these two screws and pull out lamp plate to change lamp Hanging Yoke Safety hook Zone 1 Sound sensitivity knob Built in microphone Power Fuse Zone 2 Sound sensitivity knob Voltage select switch ...

Страница 5: ...pull out of the lamp socket located inside the reflector 5 Replace with a new lamp 6 Replace lamp plate align the screw holes and fasten the screws Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp Adjust the angle of...

Страница 6: ... the Scrambler and any other non dimmable effect light from a switch panel Make sure to use a cable of at least 25 feet to provide ample distance between the control panel and the switch pack for most mobile lighting applications If you would prefer to control it directly from your DMX lighting console then we suggest a DMX compatible relay switch pack These devices are an extremely affordable sol...

Страница 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Страница 8: ...ly in order to measure correctly check to see if perhaps it is stuck Fogger or Snow output has dropped Clean with distilled water and vinegar Replace hose Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick st...

Страница 9: ...not to exceed 15 minutes 2 Fixture OFF cool down for 15 minutes LAMPS EHJ 250W 24V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 3A 250V Fast Blow PCB1 20mm Glass 3A 250V Fast Blow PCB2 20mm Glass 3A 250V Fast Blow ORDERING INFORMATION Scrambler CH 244 Fuse 3A P170FUSE003 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetli...

Отзывы: