Содержание Intelect HPL15

Страница 1: ...1 EN User Manual Intelect HPL7 and HPL15 ...

Страница 2: ...splay C Emergency stop button D Multi function knob E Calibration socket F Label showing laser data G Product identification label H Main switch I 2x2AT Fuses J 100 240 V 50 60 Hz socket K Cooling fan L Interlock M Footswitch socket N Interlock for patient button Optional ...

Страница 3: ...3 EN Accessories Laser handpiece Footswitch 4930 Safety glasses 4800 3 pole interlock 4900 Power cable 4910 Ø 38 mm Applicator Magnetic attachment 207902 Ø 26 mm Applicator Magnetic attachment 207901 ...

Страница 4: ...ply Symbology on label and device 0 I Obligation to follow instruction for use Laser stop 0473 WEEE Mark European Directive 2012 19 EU Indicates separate treatment from general waste at end of life Within the European Union EU wide legislation as implemented in each Member State requires that the waste electrical and electronic products carrying this mark must be disposed of separately from normal...

Страница 5: ...indications 9 1 7 General warning 9 2 Quick use guide 11 2 1 How to use the handpiece 14 3 Instructions for use 15 3 1 Start up 15 3 2 Mode 16 3 2 1 Continuous mode 16 3 2 2 Interrupted mode 17 3 2 3 Pulsed mode 17 3 2 4 Single Pulse mode 18 3 2 5 Burst mode 18 3 2 6 Stochastic mode 19 3 2 7 Anti Inflam mode 19 3 3 CPS 20 3 4 Favorites 22 3 5 Guide 22 3 6 Programming 22 3 7 Calibration 23 3 8 Sett...

Страница 6: ... 26 5 Standards and safety 28 5 1 Laser standards 28 5 2 Safety features 28 5 3 Classification 30 6 Maintenance 32 6 1 Ordinary maintenance 32 6 2 Troubleshooting and periodical maintenance 33 6 3 Alarms 34 7 Labels 35 8 Warranty 36 9 Technical data 37 10 EMC tables 38 ...

Страница 7: ...latter allows therapeutic results to be maximized in complete safety limiting the thermal effects on tissue Intelect HPL 7 and HPL15 are highly innovative therapeutic lasers The equipment has been designed with a range of important features Real Time operating system and 7 touch screen Interactive library with over 60 therapeutic protocols Various power configurations up to 7W effective Intelect H...

Страница 8: ...nel Physical Therapist Rehabilitation Therapist Athletics Therapist Physical Therapist Assistant or Chiropractor Assistant under supervision of a Licensed Physical Therapist or Chiropractor Sub acromial conflicts Cuff injuries Arthrosis Epicondylitisi Epitrocleitis Bursitis Fracture aftereffects Tendinitis Carpal tunnel syndrome Pubalgia Gonarthrosis Reconstruction of anterior cruciate ligament Cr...

Страница 9: ...ents 1 6 Contraindications Before application the user must read the user manual completely and attentively including the treatment method indications and contra indications the warnings and the operation instructions To avoid the risk of electric shock this equipment must only be connected to a mains supply with protective ground The device must be used with the power cable supplied The power cab...

Страница 10: ...us gas Poor function of the ray absence or deviation may indicate incorrect operation of the emission Fixing electric circuits must be carried about by authorised and skilled personnel with a document from the manufacturer We recommend contacting the manufacturer of the device in the event of breakage to avoid loss of warranty conditions Do not use other accessories than the ones provided by DJO O...

Страница 11: ... 7 and HPL15 please contact DJO contact list at the end of this User Manual Connect the pneumatic footswitch cable to the appropriate socket on the back of the machine Connect the interlock to the appropriate central socket on the back of the machine After connecting the interlock to the machine Intelect HPL 7 and HPL15 is fully functional the connection to the treatment room door switch must be c...

Страница 12: ...dpiece Make sure that those present operator and patient wear certified protective glasses After the welcome screen a keyboard will be displayed Enter the password to start up the machine The password is 1 2 3 4 Select the mode to start the therapy ...

Страница 13: ...ll automatically adjust the therapy time top left square To set the chosen power click on the laser power icon and turn the knob clockwise The parameter is displayed in the lower left of the screen Laser emission starts by pressing play on the bottom right area of the screen and pressing the pneumatic footswitch During the emission the sound output signal intensity adjustable gets activated and th...

Страница 14: ...applicator supplied We recommend performing the calibration procedure prior to every treatment To switch the device off securely complete the treatment and stop emitting from the laser turn the unit off with the button at the back of the machine ensure it is positioned at 0 To complete the disconnection for optimal safety remove the power cable from the device 2 1 How to use the handpiece ...

Страница 15: ...witch to activate laser emission The handpiece must always be held perpendicular to the patient you can increase or decrease the power by turning the knob clockwise counter clockwise The lower part of the screen shows the actual power delivered the time the amount of energy transferred and the temperature of the laser head 3 1 Start up After the device is switched on and the welcome screen has app...

Страница 16: ... effect increasing the production of ATP Output is delivered in a constant way The continuous output mode is fundamental to trigger a tissue regeneration process it is indicated for deep injury pathologies To start the treatment choose continuous emission mode set power parameter by pressing laser power and energy quantity by pressing Joule take out the handpiece from its holder put on the handpie...

Страница 17: ...rmal impact This mode enables the laser emission optimization depending on the skin type By choosing the duration of the impuls 500ms it is possible to change the frequency by selecting the appropriate option on the screen After setting the parameters of frequency and pulse duration by clicking on laser power you can change the working power while clicking joules in the upper right of the screen a...

Страница 18: ...e The lower part of the screen shows the actual power delivered the time the amount of energy transferred and the temperature of the laser head This mode lets you set the pulse frequency and the duration of each pulse Selecting the pulse duration 500ms allows you to change the frequency 10Hz max by making the appropriate selections After setting the parameters of frequency and pulse duration by cl...

Страница 19: ... lodging putting on the applicator pressing Start and acting on the pneumatic footswitch you can begin the therapy session The lower part of the screen shows the actual power delivered the time the amount of energy transferred and the temperature of the laser head 3 2 7 Anti Inflam mode Pulsed emission mode is designed to allow to obtain an anti inflammatory effect by limiting the thermal effect d...

Страница 20: ... to treat It is possible to select the anatomical area from the displayed human body figure pressing on the chosen area accesses the respective treatment protocols 3 3 CPS For each anatomical district there are therapeutic protocols for the treatment of specific pathologies of the musculoskeletal system Once a pathology has been selected you will be invited to specify Patient s age Patient s photo...

Страница 21: ...s holder putting on the applicator pressing Start and acting on the pneumatic footswitch you can begin the therapy session The lower part of the screen shows the actual power delivered the time the amount of energy transferred and the temperature of the laser head By pressing inside the left square the one next to treatment time you can see the protocol for the pathology ...

Страница 22: ...is possible to start treatment after selecting a protocol This section displays the therapeutic indications and contraindications and some information on the proper use of the device In this section you can set favorite protocols first selecting the output mode and then the treatment parameters time power joules etc following the previous instructions ...

Страница 23: ...nt if necessary For this reason Intelect HPL 7 and HPL15 features a Calibration function Using this test it is possible to measure the real power emitted allowing the operator to check correct laser emission 1 Remove the magnetic spacer from the handpiece 2 Check that the lens fitted in the end of the handpiece is perfectly clean if it is dirty clean it 3 Insert the handpiece into the calibration ...

Страница 24: ...g the use of the product treatment Beep In Beep it is possible to switch touchscreen button sounds on or off Maintenance Add a password for the internal management of the device reserved section BackLight it is possible to adjust the brightness of the screen using the dial Therapy hours the effective number of hours of therapy carried out Operation hours the time in hours that the machine has been...

Страница 25: ...to the machine any damage could stop the machine working correctly Never pull the machine using the cable Pay attention to the location of the Intelect HPL 7 and HPL15 avoid trapping the cable in doors between treatment bed and trolley or in other pinching hazards such as drawers Pay attention to the positioning of the Intelect HPL 7 and HPL15 and avoid treading on the cable when moving around it ...

Страница 26: ... the tissue the thickness of the fat layer the depth and area of the pathology and the sensitivity of the patient The emission of the laser is the result of pressure applied to the footswitch and the power value shown on the touch screen display The exposure of tissue to laser radiation must be done using an applicator possibly in contact with the skin The applicator must be positioned so that it ...

Страница 27: ...the applicator will be positioned Ensure that the surface of the skin is clean and most importantly is not wet or sweaty Remember that thermal sensitivity varies from patient to patient and from area to area on the same person and that the level of pigmentation greatly influences the absorption of energy and therefore the emission times at equal power will not remain constant The perpendicular ang...

Страница 28: ...k Through a special button patient button connected to the machine it is possible to interrupt the treatment at any time Connection interlock Intelect HPL 7 and HPL15 features an interlock connector positioned above the footswitch connector on the back of the machine This acts as a series contact for the footswitch and is connected to the door switch fitted to the door of the treatment room The co...

Страница 29: ...asses supplied cod 651 do not shield from or prevent the visibility of light signals We recommend to use the laser glasses supplied by DJO The operator must constantly and carefully monitor the safety of the patient during the treatment taking necessary steps to avoid injury Protective glasses DJO accepts no responsibility for damage or injury to persons or property due to the incorrect use of its...

Страница 30: ...ratus unsuitable for use in the presence of a mix of flammable anesthetic and air or oxygen or with nitrogen protoxide Apparatus for continuous function Based upon laser emission characteristics IEC 60825 1 2014 paragraph d table 4 the apparatus is classified as Class IV Intelect HPL 7 and HPL15 conforms with RoHS specifications and uses recycled materials General description Intelect HPL 7 and HP...

Страница 31: ...ems due to the distance between circuit boards and ventilation grills The recommended environments for use are hospital clinic and private center The recommended environments for use have to have the following environmental and electrical requirements electrical system that respects the standards of the installation country no reflective surface like mirror laser attention symbol red light outside...

Страница 32: ...socket use a cotton bud moistened with liquid detergent Dry immediately with a clean cotton bud To clean the laser protection window use a jet of dry compressed air If the window is very dirty a cotton bud moistened with ethyl alcohol can be used dry immediately with a jet of dry compressed air To clean the screen and the case use a professional microfiber wipes for screen cleaning Careful cleanin...

Страница 33: ...tre Pressing a button does not have the desired effect A Probable button fault B Probable control circuit fault A Contact the DJO Assistance Centre The calibration check shows FAULT A Probable optical fibre breakage B Degraded laser emission C Calibration check system deteriorated or dirty A Clean the laser protection window B Clean the calibration unit C Contact the DJO Assistance Centre Checking...

Страница 34: ... Probable cause Solution CHECK MACHINE HOURS The laser electronics should be checked Contact the DJO Assistance Centre TEMPERATURE ALARM The working temperature is high Cool the laser keeping the machine switched on If the problem persists contact the DJO Assistance Centre In the case of malfunction the following warnings may be shown on the Intelect HPL 7 and HPL15 display 6 3 Alarms ...

Страница 35: ...tor for optical fibre B Laser hazard C Laser data plate D Product identification plate Intelect HPL 7 E Sticker showing footswitch connection F Sticker showing interlock connection for patient button Optional G Interlock connection F G ...

Страница 36: ...chase If these Products fail to function during the two year warranty period due to a defect in material or workmanship at the Company s option Company or the selling dealer will repair or replace the respective Product without charge within a period of thirty 30 days from the date on which the Product is returned to the Company or the dealer Malfunctions failures or problems caused by improper us...

Страница 37: ...for laser emission at handpiece exit in accordance with standard IEC 60825 1 Display Colour TFT 7 Touch screen Supply 100 240V 50 60Hz Absorption power 160 VA Dimensions 390 x 282 x 170 mm Weight 3 8 kg HPL 7 3 9 kg HPL 15 Laser Class IV Beam divergence 25 Puls Width 1 1000 ms IP Classification IPX0 device IPX0 handpiece IPX4 pneumatic footswitch Terms operating 10 30 C 30 75 humidity non condensi...

Страница 38: ...38 EN 10 EMC tables ...

Страница 39: ...39 EN ...

Страница 40: ...40 EN ...

Страница 41: ...41 EN ...

Страница 42: ...866 5032 E canada orders DJOglobal com CHINA T 8621 6031 9989 F 8621 6031 9709 E information_china DJOglobal com DENMARK FINLAND NORWAY SWEDEN T Denmark 89 88 48 57 T Finland 46 40 39 40 00 T Norway 23 96 09 27 T Sweden 040 39 40 00 E info nordic DJOglobal com FRANCE T 33 0 5 59 52 86 90 F 33 0 5 59 52 86 91 E sce cial DJOglobal com GERMANY T 49 761 4566 01 F 49 761 456655 01 E infoservice DJOglob...