background image

21

Product Manual - VaporMan 125

®

 Manifold Vaporizer System

Warranty Policy

Chart Inc  (“Chart”) warrants to the Purchaser that the Bulk 

CO

2

 Storage Systems equipment (the “Equipment”) shall 

be free from any defects in workmanship and materials; 

provided, however, that this warranty shall be limited to 

Equipment found to be defective within a period of one (1) 

year from initial use or eighteen (18) months from the date of 

shipment, whichever expires first, except that parts sold as a 

spare or for replacement are warranted for ninety (90) days 

from the date of shipment  Chart also warrants the vacuum 

in the Equipment for five (5) years from the date of the 

original Chart invoice  Chart warrants that its services will 

be performed in a professional and workmanlike manner  All 

Chart services are warranted for a period of ninety (90) days 

from the date of their completion 

Purchaser agrees that as a pre-condition to any Chart liability 

hereunder, Purchaser or its appointed agents shall fully 

inspect all Equipment immediately upon delivery and shall 

give Chart written notice of any claim or purported defect 

within ten (10) days after discovery of such defect 

As a further pre-condition to any Chart liability hereunder, 

an approved Chart service company must supply both parts 

replacement and labor and Purchaser must strictly adhere 

to the Warranty Claims Procedure set forth below  Chart’s 

sole and exclusive liability under this limited warranty is to 

the original Purchaser only and is, at Chart’s sole option: (1) 

repair or replacement of the defective Equipment or parts 

thereof; or (2) refund the net purchase price of the defective 

Equipment or parts thereof paid by the original Purchaser; or 

(3) in the case of nonconforming services, provide equivalent 

services or refund the net price paid by the original 

Purchaser for such services  Chart shall not be responsible 

for providing working access to the defect, including 

disassembly and reassembly of Equipment or for providing 

transportation to and from Chart’s repair or factory facility, 

all of which shall be at Purchaser’s risk and expense 

This limited warranty does not apply to Equipment that Chart 

determines to have been caused by the effects of normal 

wear and tear, erosion, corrosion, fire, flood, explosion or 

other excessive external forces, misuse, abuse, negligence or 

accident  Alterations or repairs by any party other than those 

designated and approved in writing by Chart, or installation, 

storage, maintenance or operation of such Equipment in a 

manner inconsistent with Chart accepted practices, normal 

operating instructions, specifications and drawings, or 

outside the specified design conditions, unless pre-authorized 

in writing by Chart, shall void this limited warranty  

Modifications in any way to the Equipment without Chart’s 

prior written approval shall render this warranty void  This 

limited warranty does not apply to Equipment comprised 

of materials provided or a design stipulated by Purchaser 

or to Equipment purchased used  Negligent handling of the 

vacuum by the Purchaser or others, or testing of the vacuum 

levels by any party other than Chart designated and approved 

party shall render the vacuum warranty void 

Repairs or replacements made pursuant to warranty shall 

not renew or extend the applicable original warranty period; 

provided however, that any such repairs or replacement of 

Equipment or parts thereof shall be warranted for the time 

remaining in the original warranty period or thirty days, 

whichever is longer 

Individual parts replacements under warranty and with a 

component list price less than $50 00 will be replaced at no 

charge  Individual components costs exceeding $50 00 that 

are replaced under warranty will be invoiced to the Purchaser 

and the Purchaser will be issued credit based on results of 

Chart’s evaluation of the returned component(s)  The Return 

Material Authorization (RMA) process must be initiated 

prior to shipment of any replacement parts 

Chart is not liable for component replacement labor 

exceeding two hours for actual replacement and two hours 

travel time (four hours @ 65 00/hour maximum) 

Chart specifically makes no warranties or guarantees, 

expressed or implied, including the warranties of 

merchantability of fitness for a particular purpose or use, 

or warranties arising from course of dealing or usage of 

trade, which are all expressly disclaimed, other than limited 

warranties expressly specified herein.

In no event shall Chart be liable for any special, indirect, 

incidental or consequential damages, including but not 

limited to loss of profits, lost opportunity, loss of use of 

the equipment, CO

2

 loss, cost of capital, cost of substitute 

equipment, downtime costs, costs of delays nor for any 

penalties, whether any such claim for the same is based 

on contract, warranty, tort, negligence, strict liability or 

otherwise, Chart’s liability for any such claims whether 

in contract, warranty, negligence, tort, strict liability, or 

otherwise or for any loss or damage arising out of, connected 

with, or from any design, sale, installation, operation or use 

of the equipment or performance of any services rendered 

by Chart, shall in no event exceed the purchase price paid to 

Chart by purchaser for the specific equipment or part thereof 

or for the services giving rise to the claim  Purchaser agrees 

to defend, indemnify and hold Chart harmless from any 

third party claims arising out the use, sale, or lease of the 

equipment 

This warranty policy is not intended to replace or supersede 

the warranties, limitations, exclusive remedy and disclaimers 

set forth in Chart’s Terms and Conditions of Sale  In the 

event of a conflict between Chart’s Terms and Conditions 

Warranty

Содержание VaporMan 125

Страница 1: ...Part Number 20749848 Rev B 2018 Chart Inc Designed and Built by Chart Inc 407 7th Street NW New Prague MN 56071 USA 800 400 4683 Product Manual VaporMan 125 Manifold Vaporizer System...

Страница 2: ......

Страница 3: ...ow Regulator 6 Operations 7 Initial Inspections 7 Filling Procedures 7 Installing the VaporMan 125 Unit 7 Plumbing Procedures 8 Carbo Max 1000 Bulk CO2 System Parts to be Added 8 Carbo Max 1000 Bulk C...

Страница 4: ...aporMan 125 Unit with Carbo Max 750 Bulk CO2 System 19 VaporMan 125 Unit with Carbo Max 1000 Bulk CO2 System 19 VaporMan 125 Unit with Perma Cyl MicroBulk Storage System 20 Warranty 21 Warranty Policy...

Страница 5: ...ls and kits provided by Chart This manual contains information regarding the safe operation and handling of liquid carbon dioxide with the cylinder and the vaporizer manifold system It should be thoro...

Страница 6: ...f a condition that can result in equipment or component damage Note A statement that contains information that is important enough to emphasize or repeat Acronyms Abbreviations The following acronyms...

Страница 7: ...ith liquid CO2 cold pipes and equipment or cold gas exists Safety goggles or a face shield should be worn at all times when connecting to fill connections while filling the tank and during disconnecti...

Страница 8: ...Monitoring Systems The Analox 50 and Ax 50 Carbon Dioxide Analyzers are precision instruments that provide continuous accurate monitoring of CO2 levels to ensure a safe working environment for your em...

Страница 9: ...a plug and play assembly The vaporizers are connected in a specific order and the vaporizer selection was intentional The parallel vaporizer is used to vaporize the liquid into cold gas The gas is th...

Страница 10: ...bo Max 1000 Bulk CO2 System tanks or who have one Perma Cyl MicroBulk Storage System tank there are two optional kits that will need to be purchased as well The kit names are KIT CARBOMAX VAPORMAN 100...

Страница 11: ...ns A place that has circulation is recommended to aid in melting the ice that might build up on the vaporizers during operation The VaporMan 125 unit will then need to be connected to the tank or tank...

Страница 12: ...in the following illustrations you will remove the Economizing sections Gas Use sections and the Pressure Building sections The parts to be reused are shown on top as well as the parts to be added Car...

Страница 13: ...9 Operations Product Manual VaporMan 125 Manifold Vaporizer System Carbo Max 750 Bulk CO2 System Parts to be Added Carbo Max 750 Bulk CO2 System Parts to be Removed...

Страница 14: ...not connected the tanks may not distribute CO2 to the VaporMan 125 unit equally The check valves are in place to prevent any back flow into each tank The check valves also ensure that the tanks equal...

Страница 15: ...dy VaporMan 125 system pressure is too low or does not build pressure at a sufficient rate VaporMan 125 unit or system is leaking If the pressure does not build and stays at a setting lower than desir...

Страница 16: ......

Страница 17: ...re Designation Description Function PG 1 PG 2 DIAL 0 400 PSI 1 4 MPT CBM PN 13321014 PRESSURE GAUGE TANK PRESSURE ECON PRESSURE R 1 REGULATOR 250 NPT 150 PSI ECON PN 13154842 ECONOMIZER REGULATOR RV 2...

Страница 18: ...13154842 ECONOMIZER REGULATOR R 2 REGULATOR 250 NPT 200 PSI SF PN 13154834 SURE FILL REGULATOR RV 1 RV BRS 1 2MPT 300 PSI PN 11708400 PRIMARY SAFETY RELIEF VALVE RV 2 RV BRS 1 2MPT 450 PSI PN 1170845...

Страница 19: ...4 MPT CBM PN 11940305 R 1 REGULATOR 250 NPT 150 PSI ECON PN 13154842 R 2 REGULATOR 250 NPT 200 PSI SF PN 13154834 R 3 REGULATOR 250 NPT 125 PSI PB PN 14743180 RV 1 RV BRS 1 2MPT 300 PSI PN 11708400 R...

Страница 20: ...16 Specifications Product Manual VaporMan 125 Manifold Vaporizer System VaporMan 125 Unit with Perma Cyl MicroBulk Storage System...

Страница 21: ...DICATOR PI 1 PRESSURE INDICATOR R 1 PRESS BUILDING REG R 2 SUREFILL REG RV 1 RELIEF VALVE RV 2 LINE RELIEV BD 1 BURST DISC Piping Ref No Description A TOP FILL B LIQUID WITHDRAWAL C PRESSURE BUILDING...

Страница 22: ...18 Specifications Product Manual VaporMan 125 Manifold Vaporizer System Set up and Dimensions VaporMan 125 Unit...

Страница 23: ...19 Specifications Product Manual VaporMan 125 Manifold Vaporizer System VaporMan 125 Unit with Carbo Max 750 Bulk CO2 System VaporMan 125 Unit with Carbo Max 1000 Bulk CO2 System...

Страница 24: ...20 Specifications Product Manual VaporMan 125 Manifold Vaporizer System VaporMan 125 Unit with Perma Cyl MicroBulk Storage System...

Страница 25: ...fications in any way to the Equipment without Chart s prior written approval shall render this warranty void This limited warranty does not apply to Equipment comprised of materials provided or a desi...

Страница 26: ...Or by writing to Chart Inc 407 7th Street NW New Prague MN 56071 2 Authorization must be obtained from Chart prior to shipping any Equipment to Chart facilities In order to process the return of a tan...

Отзывы: