background image

Issue K

19

®

charnwood

BISHOPS   WAY,   NEWPORT,   ISLE   OF   WIGHT     PO30   5WS,   UNITED   KINGDOM

T:+ 4 4 (0 )19 8 3 5 377 9 9 • F :+ 4 4 (0 )19 8 3 5 377 8 8 • SPA RE S@C H A RN WO O D .C O M • WWW.C H A RN WO O D .C O M

®

C-FOUR

PARTS LIST

Item

Part No.

Description

1#

002/BR001/A

Door Assembly

2

008/FFW026

1/4 Heavy Brass Washer

3

006/PV19

Glass (inc seal)

4

008/BR014

Handle Pivot Pin

5

004/BW23

Glass Retainer

6

008/FFS018

M6x16 C'sunk Skt Hd Screw

7

008/PV21

Rope Door Seal

8

004/BR005

Air Box Control Plate

9

004/BR007

Air Inlet Slide

10#

001/BR010

Firebox

11

004/BR016

Control Rod

12

002/BR017

Fuel Retainer BR

13

010/BR031

Throat Plate

14

010/BR029

RH Sideplate

15

010/BR030

Inner Backplate

16

004/BR040

Airbox Cover

17

002/DY21

Riddler Knob

18

008/BR044

Gasket Blanking Plate

19

008/BR006

Gasket Airbox

20

008/FFB034

M8 Nyloc nut

21

012/BR011

Serial No. Label

22

002/PV13

Door Latch

23

008/FFW025

M8 Wavy Washer

24

008/FFW007

3/8" Plain Light Washer

25

008/FFS050

M8 Bolt 30mm Long

26

008/AY37

Air Control Knob

27

002/BR034

Wood Ash Retainer

28

008/BR045

Air Box Gasket

34

008/FFS025

M6 x 12 Bright Pozi Pan Hd

35

008/BR047

Back Gasket

36

008/FFS059

M8 x 20 Hex Hd Bolt

37

008/BR052

Felt Washer

38

011/PV26

Side Gasket

39

004/BR053

Air Inlet Spigot assy

40

004/BR054

Blanking Plate

41

004/DY22

Riddler Blanking Disk

42

010/EY12

Serial Number Hanger Bracket

43#

010/PV33

Vert Rear Flue Adaptor

44

002/PV12B

Flue Collar

45

012/PV09

Blanking Plate

46

002/BR020

Hinge

48

004/BR033

Ashpan

49

002/EY03

Grate Plate

50

010/EY04

L.H. Grate Support

51

010/EY05

R.H. Grate Support

52

010/EY06

Front Grate Support

53

010/BR035

Rear Grate Support

54

010/EY13

Riddler Rod Assy

55*

008/PV55

Glass Seal

56*

008/FW29

Door Seal Adhesive

57#

002/BR012

Handle Casting

58

004/BR015

Clicker Retainer Plate

59

008/ES36/01

Brass Ball Catch

60

010/BR022

Grate Kit

61*

010/EW51

Ash Carrier (Optional Extra)

62

008/BW39/S

Hinge Pin Set

63

008/FFW015

Spring Washer (Thackery Type)

64

008/FFB007

M8 x 100mm Allen Head Bolt

65#

010/BR050

Store Stand

66*

010/BR057

Heat Shield

29

010/BR028

LH Sideplate

30

008/BR012

Wooden Handle

31

008/FFS003

Pan Head Screw M5 x 10

32

008/FFS078

Pozi Pan Head 4.2 x 9.5

33

008/FFB003

Coach Bolt M6 x 20

(Optional Extra)

Item

Part No.

Description

To obtain spare parts please contact your local stockist giving Model, Part No. and
Description. In case of difficulty contact the manufacturer at the address shown.

* These items are not shown on the drawing.
# Please specify colour when ordering.
This drawing is for identification purposes only.

17

52

50

48

51

53

49

68

60

54

Optional Grate Kit

14

15

13

46

12

27

22

5

33

31

45

21

34

19

8

9

16

18

40

25

11

17

26

28

37

29

32

42

43

44

32

20

24

23

7

30

1

2

3

6

10

35

58

59

57

38

38

36

62

41

65

63

64

67

4

39

Содержание C-Four

Страница 1: ...Operating Installation Instructions charnwood ...

Страница 2: ......

Страница 3: ...Servicing Trouble Shooting CO Alarm If you need further help Health Safety Precautions CO Alarms Specification Chimney Hearth Fire Surround Connection to Flues Soot Doors Pre Lighting Check Commissioning Clean Air Act Information Dimensions Parts Lists Certification 4 4 5 5 5 6 6 6 6 6 7 7 7 9 10 11 11 11 11 12 13 14 INSTALLATION INSTRUCTIONS 5 9 9 9 9 Controlling The Fire Ref C FOUR v1 09 11 ...

Страница 4: ...at the stove will be hot and that it is made from hard materials ensure that you have good balance before operating the fire Do not use an aerosol spray on or near the stove when it is alight There is a risk of explosion or flash ignition of the spray The stove is suitable for intermittent operation This stove has been designated to burn wood Only dry well seasoned wood should be burnt on this app...

Страница 5: ...h airwash to keep the glass clean However it will not always be possible to keep the glass clean with the air control fully closed Keep the firebox well filled but do not allow fuel to spill over the top of the fuel retainer Logs should be evenly distributed filling the firebed to give the most pleasing flame pattern The air control must be fully opened after refuelling until the flames are establ...

Страница 6: ...hese operations The front of the throat plate is pulled forward and then lowered as shown in Fig 3 Any sooty deposits should then be swept from the plate and into the fire Return the throat plate to its correct position raise the front of the plate push it back and then lower it onto the retaining lugs CHIMNEY SWEEPING SERVICING The chimney should be swept at least twice a year Where the top outle...

Страница 7: ... to give advice if necessary CO ALARM IF YOU NEED FURTHER HELP TROUBLE SHOOTING Fire Will Not Burn Blackening of Door Glass Fume Emission Warning Note Properly installed and operated this appliance will not emit fumes Occasional fumes from de ashing and re fuelling may occur Check that a the air inlet is not obstructed in any way b chimneys and flueways are clear c a suitable fuel is being used d ...

Страница 8: ......

Страница 9: ...are or round and MUST NOT BE LESS THAN 125 mm 5 INCHES If an existing chimney is to be used it must be swept and checked it must be in good condition free from cracks and blockages and should not have an excessive cross sectional area If you find that the chimney is in poor condition then expert advice should be sought regarding the necessity of having the chimney lined If it is found necessary to...

Страница 10: ...st be kept to a minimum and should not be more than 125mm 5 inches long The stove comes with the blanking plate fitted to the top flue outlet The seal for the outlet is a 180mm dia ring of rope seal The seal for the outlet is a length of adhesive backed fibre webbing supplied with instructions This is applied to the flue collar or the Vertical Rear Flue adapter for rear outlet installations For to...

Страница 11: ... smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for E...

Страница 12: ... C FOUR DIMENSIONS mm 12 763 710 608 194 5 64 5 OD 458 62 ID 44 5 Dimensions of the Optional Vertical Rear Flue Connector 140 i d to suit 125mm 5 flue pipe ...

Страница 13: ...ddler Blanking Disk 42 010 EY12 Serial Number Hanger Bracket 43 010 PV33 Vert Rear Flue Adaptor 44 002 PV12B Flue Collar 45 012 PV09 Blanking Plate 46 002 BR020 Hinge 48 004 BR033 Ashpan 49 002 EY03 Grate Plate 50 010 EY04 L H Grate Support 51 010 EY05 R H Grate Support 52 010 EY06 Front Grate Support 53 010 BR035 Rear Grate Support 54 010 EY13 Riddler Rod Assy 55 008 PV55 Glass Seal 56 008 FW29 D...

Страница 14: ...ear Emission of CO in combustion products Flue gas temperature Space heating thermal output Energy efficiency A Division of A J Wells Sons Limited Registered in England No 03809371 11 Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS SONS LTD A J WELLS SONS LTD BR080 CPD 2011 600 mm 600 mm 0 18 281 C 4 9kW 78 3 Wood Logs ...

Страница 15: ......

Страница 16: ... R e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 71 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 44 0 1983 537777 F 44 0 1983 537788 CHARNWOOD AJWELLS CO UK WWW CHARNWOOD COM y o u r p re m i e r d e a l e r REV C FOUR v1 08 11 ...

Отзывы: