background image

®

C-FOUR DIMENSIONS (mm)

12

763

710

608

194.5

64.5 OD

458

62 ID

44.5

Dimensions of the

Optional Vertical

Rear Flue Connector

140 i/d to suit 125mm (5")

flue pipe

Содержание C-Four

Страница 1: ...Operating Installation Instructions charnwood ...

Страница 2: ......

Страница 3: ...Servicing Trouble Shooting CO Alarm If you need further help Health Safety Precautions CO Alarms Specification Chimney Hearth Fire Surround Connection to Flues Soot Doors Pre Lighting Check Commissioning Clean Air Act Information Dimensions Parts Lists Certification 4 4 5 5 5 6 6 6 6 6 7 7 7 9 10 11 11 11 11 12 13 14 INSTALLATION INSTRUCTIONS 5 9 9 9 9 Controlling The Fire Ref C FOUR v1 09 11 ...

Страница 4: ...at the stove will be hot and that it is made from hard materials ensure that you have good balance before operating the fire Do not use an aerosol spray on or near the stove when it is alight There is a risk of explosion or flash ignition of the spray The stove is suitable for intermittent operation This stove has been designated to burn wood Only dry well seasoned wood should be burnt on this app...

Страница 5: ...h airwash to keep the glass clean However it will not always be possible to keep the glass clean with the air control fully closed Keep the firebox well filled but do not allow fuel to spill over the top of the fuel retainer Logs should be evenly distributed filling the firebed to give the most pleasing flame pattern The air control must be fully opened after refuelling until the flames are establ...

Страница 6: ...hese operations The front of the throat plate is pulled forward and then lowered as shown in Fig 3 Any sooty deposits should then be swept from the plate and into the fire Return the throat plate to its correct position raise the front of the plate push it back and then lower it onto the retaining lugs CHIMNEY SWEEPING SERVICING The chimney should be swept at least twice a year Where the top outle...

Страница 7: ... to give advice if necessary CO ALARM IF YOU NEED FURTHER HELP TROUBLE SHOOTING Fire Will Not Burn Blackening of Door Glass Fume Emission Warning Note Properly installed and operated this appliance will not emit fumes Occasional fumes from de ashing and re fuelling may occur Check that a the air inlet is not obstructed in any way b chimneys and flueways are clear c a suitable fuel is being used d ...

Страница 8: ......

Страница 9: ...are or round and MUST NOT BE LESS THAN 125 mm 5 INCHES If an existing chimney is to be used it must be swept and checked it must be in good condition free from cracks and blockages and should not have an excessive cross sectional area If you find that the chimney is in poor condition then expert advice should be sought regarding the necessity of having the chimney lined If it is found necessary to...

Страница 10: ...st be kept to a minimum and should not be more than 125mm 5 inches long The stove comes with the blanking plate fitted to the top flue outlet The seal for the outlet is a 180mm dia ring of rope seal The seal for the outlet is a length of adhesive backed fibre webbing supplied with instructions This is applied to the flue collar or the Vertical Rear Flue adapter for rear outlet installations For to...

Страница 11: ... smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for E...

Страница 12: ... C FOUR DIMENSIONS mm 12 763 710 608 194 5 64 5 OD 458 62 ID 44 5 Dimensions of the Optional Vertical Rear Flue Connector 140 i d to suit 125mm 5 flue pipe ...

Страница 13: ...ddler Blanking Disk 42 010 EY12 Serial Number Hanger Bracket 43 010 PV33 Vert Rear Flue Adaptor 44 002 PV12B Flue Collar 45 012 PV09 Blanking Plate 46 002 BR020 Hinge 48 004 BR033 Ashpan 49 002 EY03 Grate Plate 50 010 EY04 L H Grate Support 51 010 EY05 R H Grate Support 52 010 EY06 Front Grate Support 53 010 BR035 Rear Grate Support 54 010 EY13 Riddler Rod Assy 55 008 PV55 Glass Seal 56 008 FW29 D...

Страница 14: ...ear Emission of CO in combustion products Flue gas temperature Space heating thermal output Energy efficiency A Division of A J Wells Sons Limited Registered in England No 03809371 11 Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS SONS LTD A J WELLS SONS LTD BR080 CPD 2011 600 mm 600 mm 0 18 281 C 4 9kW 78 3 Wood Logs ...

Страница 15: ......

Страница 16: ... R e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 71 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 44 0 1983 537777 F 44 0 1983 537788 CHARNWOOD AJWELLS CO UK WWW CHARNWOOD COM y o u r p re m i e r d e a l e r REV C FOUR v1 08 11 ...

Отзывы: